How to Pump down the Aircon System in the ship?Bakit tinawag pump down? Ano ba talaga ang Pump down?

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 พ.ย. 2024

ความคิดเห็น • 44

  • @rieneriofajada1915
    @rieneriofajada1915 2 ปีที่แล้ว +1

    Thank you chief for your very informative video. Many aspiring marine engineers will be guided by your contents.

  • @savinduthilakshana959
    @savinduthilakshana959 3 ปีที่แล้ว

    Very importen video thank you chief.please continue more more videos

  • @s895s607
    @s895s607 2 ปีที่แล้ว +1

    THANKS SIR ,YOUR VIDIO IS VERY GOOD

  • @SalmanKhan-dg8lp
    @SalmanKhan-dg8lp 2 ปีที่แล้ว

    Thanks for this valuable video,

  • @raymondarayan4645
    @raymondarayan4645 3 ปีที่แล้ว +1

    Nice Sir...

  • @abahstriker937
    @abahstriker937 3 ปีที่แล้ว

    Good job !!!
    Good video
    Stay conn

  • @bisayangdakonibai6632
    @bisayangdakonibai6632 3 ปีที่แล้ว

    Nice video sir.
    Great sharing.
    Stay safe

  • @seamananagat7108
    @seamananagat7108 3 ปีที่แล้ว

    Good video sir. I learned from it👍👍👍

  • @singhraju4000
    @singhraju4000 3 ปีที่แล้ว

    Good day Sir, Thanks for the your valuable video . please Sir make some videos on troubleshooting on control circuit. Thanks 👍👍👍👍

  • @gavinofuedan2664
    @gavinofuedan2664 3 ปีที่แล้ว

    thanks sir for sharing your knowledge

  • @RaymondGatdula23
    @RaymondGatdula23 3 ปีที่แล้ว +1

    Sir sana makagawa ka ng video ng replace filter drier sa refeer at safety device test. thanks great videos

    • @BarkoTv
      @BarkoTv  3 ปีที่แล้ว +1

      Nasa bakasyon kasi aq ngayon, noted yan sir. Pag nag replace ka ng filter drier close mo lang yong before and after na isolation valve, pero buksan mo muna yong bypass valve. Sana makatulong

    • @RaymondGatdula23
      @RaymondGatdula23 3 ปีที่แล้ว

      @@BarkoTv THANKYOU sir.. ingats at enjoy po sa bakasyon. GODBLESS po 🙏🙏🙏

    • @menandroesios8407
      @menandroesios8407 3 ปีที่แล้ว

      semi hermetic ba yang compressor na pinampdown mo sir, wala bang problema sa compressor, thanks

  • @anshumansharma7185
    @anshumansharma7185 8 หลายเดือนก่อน

    Thank you!

  • @SalmanKhan-dg8lp
    @SalmanKhan-dg8lp 2 ปีที่แล้ว

    Please make some videos of electrical fault troubleshootings

  • @mrmakinista6837
    @mrmakinista6837 2 ปีที่แล้ว

    Thank you sir

  • @angelellis.official
    @angelellis.official 3 ปีที่แล้ว

    Very Good!

  • @MrSHAWNANINO
    @MrSHAWNANINO 3 ปีที่แล้ว

    sir charging naman ng liquid refrigerant at paano mag manu2 ng defrost yung sa tubig hehe

  • @nkt9381
    @nkt9381 2 ปีที่แล้ว

    Sir anong level ba sa sightglass ng receiver/condenser ang freon during pumpdown and running?

  • @rudyardcabahug411
    @rudyardcabahug411 2 ปีที่แล้ว

    Sir magkano po sinasahod ng Refrigeration and Air-conditioning worker sa barko?

  • @cyrildelacruzjr4365
    @cyrildelacruzjr4365 3 ปีที่แล้ว

    MORE power 🙏🙏 leacky

  • @jomarvillasor6448
    @jomarvillasor6448 3 ปีที่แล้ว

    ilang kilo ng refrigerant each system ?
    tsaka sa may i know kung anung refrigerant ?
    suction pressure?
    discharge pressure?
    ty

  • @bernardtolentino1511
    @bernardtolentino1511 2 ปีที่แล้ว

    sir out of this topic, ask ko lng sa normal operation same po dapat ang temp ng inlet at outlet side sa filter drier diba? may possibility po ba or scenario na may temp difference between inlet and outlet po? at ano po ang problem if may temp difference po na naobserve? and additional po, sa pumping down ok lng po ba na ijumper ang LPS til 0bars ang suction pressure many times po until macollect na lahat ng refrigerant sa liquid receiver or hayaan lng na mag start stop ang compressor without altering the LPS?

    • @BarkoTv
      @BarkoTv  2 ปีที่แล้ว

      Di aq nag jujumper ng lps sir, hinahayaan q lng na ang lps mag activate, di q na sinasagad ng 0, pumpdown lng naman. About sa filter drier di concern sa temperature, kasi binabasihan q dyan ang flow pag di restricted means ok, pero sa case sayo restricted yan kasi mag kaiba ang temperature sa in and out

  • @mardujk
    @mardujk 2 ปีที่แล้ว

    when you open isolation valve has to start again pushing the botton or he detect by yourself ?

    • @BarkoTv
      @BarkoTv  2 ปีที่แล้ว

      It will start automatically, its because the low pressure de activates when you open the isolation valve

  • @TophieJrTV
    @TophieJrTV 2 ปีที่แล้ว

    Boss ano po ba ma recommend nyo po saken na Agency para Sa Seafarers, sa hvac din, apply sana ako, na pandemic kasi.. Need mag simula ulet

    • @BarkoTv
      @BarkoTv  2 ปีที่แล้ว

      Ano position mo sir na applyan? Wag mawalan ng pag asa sir, kaya mo yan, dami hiring sa online, or sa facebook group abangan mo ang mga post nila. Kagaya ng facebook group na seaman hiring

  • @نزارطاهر-ث3ف
    @نزارطاهر-ث3ف 3 ปีที่แล้ว

    👍

  • @karlomanuelmanongdo12
    @karlomanuelmanongdo12 3 ปีที่แล้ว

    Sir! ano yung mga mangyayare kapag maiwan mong bukas yung condeser during change over ng compressor?
    Salamat po

    • @BarkoTv
      @BarkoTv  3 ปีที่แล้ว

      Ang disadvantage pag di mo na pump down during securing the system ay mapupuno ang suction mo ( term ng iba ay nabilaokan yong compresaor, minsan mag overload during re starting. Pero ang solution dyan, during starting e close mo muna tpos pag malapit na mag trigger ang low suction buksan muna tpos normal operation na.

  • @yusofwongofficial7655
    @yusofwongofficial7655 3 ปีที่แล้ว

    Hi sir, thank you for your good video. after pump down happen, the compressor is shutting down for anti recycle, should we close the suction line valve ? to prevent the refrigerant going back to evaporator section ?

    • @BarkoTv
      @BarkoTv  2 ปีที่แล้ว +1

      No need sir. But if you have maintenance to your compressors or evaporator section, isolate the valves which section you are working

  • @butitottv5933
    @butitottv5933 3 ปีที่แล้ว

    King valve lng po ba Ang sinasara dyan sa pump down?

    • @BarkoTv
      @BarkoTv  2 ปีที่แล้ว

      Isang valve lng po. Out ng condenser

  • @oscarbibanco204
    @oscarbibanco204 3 ปีที่แล้ว

    sir nka stop ba ang air compressor kung magpumpdown.. ko

    • @BarkoTv
      @BarkoTv  3 ปีที่แล้ว

      running condition po sir,auto stop po pag ma reach nya po ang low suction set point.

  • @roycevanchua496
    @roycevanchua496 3 ปีที่แล้ว

    Sir minsan masyado po magalaw yung pag kuha ng video.

    • @BarkoTv
      @BarkoTv  3 ปีที่แล้ว +1

      Pasensya na sir, magalaw talaga kasi wlang camera man at pag nasa troubleahooting na, kailangan nag mamadali tayo, at bawal mag video2x habang di pa na solve kasi papagalitan tayo ni chief eng. Hehhehe

  • @호호밍-c7w
    @호호밍-c7w 3 ปีที่แล้ว

    10:44 restart air cond.

  • @remygensule758
    @remygensule758 3 ปีที่แล้ว

    Dan dan Tam's barko tv

  • @gbacon4551
    @gbacon4551 3 ปีที่แล้ว

    kuLANG KULANG, TAGALOG MO NALANG PARA HINDI KA MAHIRAPAN

    • @BarkoTv
      @BarkoTv  3 ปีที่แล้ว

      Dami kasi nag request na kasamahan natin sir na english lang po daw, mahirap man saakin pero pinipilt q lng po para makatulong po tayo. Kayo nalang po mag adjust sir kasi alam q naman basta pinoy madaling maka intindi. Salamat sa suggestion nyo po