I'm working in pharmaceutical company and my DM water plant has pseudomonas pathogen present when sample taken from cation anion and mix bed vessel and it's ten years old and it's charged by HCL and NaoH and sodium hypochlorite used for dosing to kill microorganism so let me know what to do for resolution please help
Sir apka video bahut helpful , and knowledgeable but charging ke time motor band rahegi and kitne time tak charging k liye rakhna h, charging niche se uper hoga or nhi , aise hi mb bed ka concept clear kare pls pls sir etp ka jarur dekhe
If we use best quality resin in cation, anion vessel and MB vessel. Mostly we cant reduse waste water of DM plant but we re-use some where and treat again thru other plant like STP, cooling tower, ETP where ever can be use.
R/Sir, I have DM plant, I am using top - bottom vessel with MB. How to control pH, plz let me know., How I may contact you, thanks for explaing in details
Sir etp ro k baare m kuch bataye stp ro se alag process hota h , jaise reject aur production line etp m low pressure ki se side se nikalta h mtlb stp ro ka ulta pls
DM water generation and Re-generation is both are different Generation comes under Raw water converted into DI water by using sand, carbon,cation,anion, and mixed bed. In time of re-generation we are using suitable chemicals like HCl into cation NaoH into Anion. We have the calculation how much quantity to be charge based on vessel capacity.
Sir please make a video how to calculate cooling tower fan efficiency, sump capacity, and how to calculate flow rate for chiller like 500 tr chiller take how much cooling tower flow and chilled water flow.
There some steps for regenerate MB. Backwash Settling Caustic injection Caustic rinse HCl injection HCl rinse Air mixing Final rinse . If conductivity bot getting less than 1, then repeat air mixing and then final rinse.
too much helpful brother
from Bangladesh
I m working in power station in Kuwait. There is also DM plant working same process..
Thanks Sir..
welcome
Great explanation Sir, a world of chemical reactions
Many thanks
Tq so much sir apki bahut dhanyawad 👍👍👍💐💐♥️♥️
great explanation sir
Thanks and welcome
Sir anion bed me coustic soda hi use karte hai
Bahot badiya 🙏
Thanks for liking
Great work sir ji 🙏🏼🙏🏼
So nice of you
What happens when DM water passes through the SBA vessels.. ?
What is contained its products (quality of output).
Thank you sir most useful video
So nice of you
Better use ke liye Dm water banane ke liye konsi methad vala plant lagana chahiye jinse costing Kam ho?
Investment bhale Jada karna pade
Mixed bed method.
Explanation❤ sir nice 👏👏👏🥰🥰😍
Thanks and welcome
Sir resing kitna lena iske liye kya formula h
Very nice sir ji
Thanks
Degasser blower ka kitna discharge pressure mmwc minimum and maximum hona chaiye
Jabarjast
Sir apka samjane ka tarika accha h
How much % feeling cation and anion according vessel capacity?
I'm working in pharmaceutical company and my DM water plant has pseudomonas pathogen present when sample taken from cation anion and mix bed vessel and it's ten years old and it's charged by HCL and NaoH and sodium hypochlorite used for dosing to kill microorganism so let me know what to do for resolution please help
You can use UV or ozonator for it and one more thing you can try to maintain 20 degree c water temperature it helps.
What happen If change the Cations and anions vessels... ?
That means first installed or used the Anion vessel and then used Cations vessels . ???
It will not work properly and will not parameters of permit water.
सर मिक्सबेड रि जेनरेशन कैसे करते हैं सबसे पहले कौन सा केमिकल चार्ज करते हैं और क्यों ????
Sir, please DAF k upper bhi koi video bnaye detail me kya kaam krta h kaise kaam krta h Or iski kya process h
Very nice sir
Thanks and welcome
Sir difference between
Ro plant and etp and dm plant
Humko inki need kyu pdi ek se kam ni ho skta kya?
Agar hamare soft water me t.d.s jayada he H.c.l castic ki matra kitni honi chahiye pintu hasti
sorry me bata ni sakta kyonki yeh paani ke parameter per depend karti ha
Sir lp aur hp Ka chemical HM DM tank m dose Kr skte h ya nhi yadi krenge to kya hoga
Sir apka video bahut helpful , and knowledgeable but charging ke time motor band rahegi and kitne time tak charging k liye rakhna h, charging niche se uper hoga or nhi , aise hi mb bed ka concept clear kare pls pls sir etp ka jarur dekhe
Hi, can we make distilled water on RO plant through membrane?
No
Sir, mixed bed will be filled with HCL & NAOH?
Softner me nacl kui use kiya jata he. Or nacl ka percentage kitni hogi?
Thank you sir
Welcome
Sir how much appx. Water is wasted for making 1kl dm water ?
Hi, Ro filter mein agar TDS 5 to 8 aaya hai to kya Distilled water jesa hoga?
No
Excellent boss
dm plant me ranig plant me sio2 bad jaye to pata kese chalega.. bina check kiye...
Water flow kam ho jayega.
Hello harish have you ever done job in focus energy limited, jaisalmer as chemist.
No,
Mix bed mein kaun sa Wal resignation mein kholte hain aur kya karne ke liye
सुपर
Sir aapke jankari helpful rha,but "RO plant" ka detail jankari chahiye tha.
th-cam.com/video/BtTHmdwTV8M/w-d-xo.htmlsi=1edU8Ax9y73hJlNg
Good morning sir
Sir, BRS ke बारे में details bataye.
SBA ko HCl se regeneration kiya jata h sir g
Thanks dear
Sir Ro s dm water kese beta h kay 1 se 10 tek k tds ka pani dm water ben jata h
Sir please bata dijiye
aap kya puchhna chhahte ho samajh ni aaya.
Sir, how to reduce waste water quantity for the DM plant
If we use best quality resin in cation, anion vessel and MB vessel. Mostly we cant reduse waste water of DM plant but we re-use some where and treat again thru other plant like STP, cooling tower, ETP where ever can be use.
Super
Ro ki capacity kaise nikala jata h aur sac SBA WBA MB me pH TDs kitna mainten rhna chahiye
alrready video uploaded.
Nice 👍 sir
Thanks and welcome
How calculate obr
Of DM plant
Sir cation unit m apne sbc likha h wo Strong acid cation (sac) hona chaiye .
May be dear its a writing mistake.
Thanks for watching carefully
Hello sir
DM water plant me TDS 30 se kam nhi ho rha hai plz problem bataiye
dost, aap ya to theek se recharge ni ho raha ha ya raw water ki tds bahut jyada ha.
R/Sir, I have DM plant, I am using top - bottom vessel with MB. How to control pH, plz let me know., How I may contact you, thanks for explaing in details
Is pH low or higj
Mention your no I will call
sir you can you also explain the functioning of WBA with SBA.
Will try.
@@BuildingSanchalan thank you sir. very well and precisely explained with proper diagrams for clear conceptual explanations.
Sir RO water bar bar trip ho rha hai over load per please
Check membrain
Good sir.
Sir please chiller pe video banaeye
Thanks sar
Sir SBA & SBC ki service kitni hoti h.. Kitni ghnte bad reganeration krna pdega..
Its depend on water quality
@@BuildingSanchalan Ok
Thanks sir
Welcome rohit
Thanku
Sir are you dealing in DM plant new one
No, I am Engineer
Sir ,STP mai ozonator Ka Kya kaam hota Hai, plz comments sir
पानी ट्रीट होने के बाद जो बैक्टीरिया बच जाता है उसको ओजोनेटर द्वारा खत्म कर दिया जाता है
It is not SBC it is SAC - STRONG ACID CATION , that's why Acid is used for charging, In SAC name it is mentioned that ACID!!
Dm water PH regeneration ke bad jada kam ho jaye to kya karna
Good
Sir etp ro k baare m kuch bataye stp ro se alag process hota h , jaise reject aur production line etp m low pressure ki se side se nikalta h mtlb stp ro ka ulta pls
DM water generation and Re-generation is both are different
Generation comes under Raw water converted into DI water by using sand, carbon,cation,anion, and mixed bed.
In time of re-generation we are using suitable chemicals like HCl into cation NaoH into Anion. We have the calculation how much quantity to be charge based on vessel capacity.
Dear Sorry, I dont have too much Idea.
Sir
We have bacterial growth in DM water , so is there any solution which can be add ?
Without inspection, it is difficult to say anything
D m plant five mitar ka hai pura regin bahar nekale hai regin change karna hai anion &cation regin ketna dale valu kase nekale
Can we drink DM water??
No,
Sir how can we make etp water reusable?
Can i get your whatsapp no??
Etp water for food industry
Sir kya hoga agar HCL regenration time excess le lenge . Means 100 kg instead of 60 kg
wastage of chemical and money.
I wanna talk with you about plaster resin
Kon sa resin hota
Sir kya dylisis ka system bhi ho sakta hi
Dylisis is also a filtration.
Sir dylisis plant me kitna paisa lagaga
Ketayan ka ph kitna hota h
Example : 2000 ltr/hr trate karna hai to kitna resign ka design karenge formula please sir
Fire fighting system pr video banaye sir
Sir please make a video how to calculate cooling tower fan efficiency, sump capacity, and how to calculate flow rate for chiller like 500 tr chiller take how much cooling tower flow and chilled water flow.
😊😊😊😊😊😊😊😊😊😊😊😊
Anion ka PH kitna hota hai
Pls make a video on WFI........
Carbon filter de chlorination karta hai bhai
Han
@@BuildingSanchalan sir example about twaddle for cation and anion regeneration,how to check acidity of cation bed
Sac action ka oBR ketna hai
Please sir resin and cemical ka value kase nekale video coment kare
Pls tell me about of reactive silica
Sir Hcl or naoh कितने पर्सेंट होना चाहिये जनरेशन के लिए कुछ कुछ है सब कुछ है ये स्टॅंडर्ड रहता है
5 to 6%
Usko Power Water Bolte hai
Mix bed mein bakwas kaise karte yah mixing kaise hota hai silo rans kaise karte injection kaise karte
Sir g how do mix bed charging please a video uploaded Thanks
There some steps for regenerate MB.
Backwash
Settling
Caustic injection
Caustic rinse
HCl injection
HCl rinse
Air mixing
Final rinse .
If conductivity bot getting less than 1, then repeat air mixing and then final rinse.
Anion pH kitna hota hai
Sir ye raw water Kahan se aaya
From govt supply or Earth
Bhaiya DM plant SAC ka working principle batao 🙏
Bhai SBA ( Strong Base anion ) and SCA ( strong acid anion) dono chahiye. DM plant me. Dono hardness se chemical reaction karta ha.
Please CO² plant operation per video banaye
प्रकटीकल प्लॉट द्वारा करके दिखाया जाता तो और बेहतर होता की कैसे रिचार्ज होता है कैसै कया प्रोसेस होता हैं
Sir SBC nhi hota hai SAC hota h. Strong Acid Cation
Sir WTP plants per video banaye
th-cam.com/video/pwzvpkOBur8/w-d-xo.htmlsi=MCuTDhu46vjKYlCM
Conductivity in micro simens
Where is clearifiere
Sir HCL Naoh kitne o/o ka hota hai
Yeh to chemical supplier bata sakta h
You can choose for one of the above gifts
What
Diesel mein DM water pad Gaya hai uska kaise DM water pad Gaya uska kaise
Diesel paani se hlka hota ha, paani neeche reh jaayega.
Sir SAC kahna hai?