SA 578 Plate Ultrasonic testing- Part-1 ll Scope, Instrument, Probe, Reference & Scanning patterns
ฝัง
- เผยแพร่เมื่อ 3 ต.ค. 2024
- SA 578 Plate Ultrasonic testing- Part-1 ll Scope, Instrument, Probe, Reference & Scanning patterns
Join us on WhatsApp Group for informative posts and job updates: chat.whatsapp....
For NDT Level I & II certificates renewal, Please contact us on : bit.ly/2WpT9HD
Ask your queries on: bitssurat@gmail.com
Subscribe for more videos like this : / ndtquality
Please connect with me on social media:
Facebook: / bitssurat
TH-cam: / ndtquality
Email ID: bitssurat@gmail.com
#SA578
#NDT
#UltrasonicTesting
Thanks for explaining in easy method sir, lots of thanks and love from me 🙏❤🙏
Thank you for watching
Very useful information Sir, Thnak you for sharing
Thank you for watching
Thanks apke vedio bahut hi easily samajh m aate h
Very informative video sir, Thank you so much. 👏👌
Very good explain sir.
Very nice and informative session 👍
Thanks 🙏
Thank you sir. Keep it up.
For normal and angle probe
Hello sir please make video on EN 10160
Nice sir
❤
Please find edge area no defects all edges or 75 dia accepted in all edge.
Amit sir please dgs and dac different stepwise settings and scanning
For DAC I have made videos.
I will also share DGS related videos in short time
Sir isme Jo 3 scanning pattern he usme normal default scanning and aur manufacturers 1 scanning dono me repair aaya to usko reference gain pe hi dengena aur manufacturers 2 Wale scanning me aaya to 75+ aur -5 %denge na
Yes
Sir plz make a video about SA435.
Yes, I will make it in future
@@NDTQualityThankyou so much sir
A578 clause 4 gives information on apparatus - amplitude linearity checking. Please make a video on this.
It's not covered in this video, because I have made saperate video on this topic. You can check it out in our UT playlist.
@@NDTQuality ok thanks
Is there similar session for EN 10160 for UT
I will make it in future
@@NDTQuality request you please confirm which level is more stringent in EN 10160 - S1E1 or S1E4. Thanks.
Sir, Please confirm.
@@aryasumit79 I have not refer/used that standard yet, Let me refer first, then I will get back to you
Sir kon sa manufacturer kaha use hoga kaise pata chalega
Refer company procedure for that
Amit sir please brief about pulse echo techniques to be used in instrument. Does it mean that we can't use TR probe or only TR is to be used.
You can use TR probe, No issue
Sir en-10160 code pe ek video banaiye sir
Lets see
Will make it in future
Sir plz provide a video link for FBH and pipe notching reference block.
I have not made video on this topic still
Sir what will we use to make a grid lines?
It's not required to scan full plate, so code allows to use grid scan
Gridline scan required in EN spec
Yes
Quality class 1 and quality class 2 me
Sir can you please describe ISO 4992
It's standard for UT of steel castings.
Let me study it, after that I will make video on it.
@@NDTQuality thank you sir...will be wait for your valuable video...
Wait for 25 th
Yes,
On second part I have covered acceptance standard A,B & C.
Please do watch, it's very important
Sir please iska pdf mil skta hai kya...🙏🙏🙏
Please message me personally,
I will share
Apki voice to aati hi nhi h
In some previous videos, this problem was there. But nowadays we have improved this
Angel probe 😂
😅
Spelling mistake