Connecting Grounds and Removing Porcelain Suspension Insulators on 69kv line

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ก.ย. 2024
  • Crews remove and replace

ความคิดเห็น • 53

  • @rickymundy8663
    @rickymundy8663 10 หลายเดือนก่อน +3

    Working inside angle ! Had the rope sling got cut or come loose come loose or broke while the string was disconnected employee on inside of that angle would have had the full strain of that span applied to that jumper. Would have been hurt and or pulled out of that bucket. Always think a step ahead “ what if this happens “. This is the way lineman must plan their work.

    • @QuiksiIver
      @QuiksiIver 2 หลายเดือนก่อน

      also attaching earths hot side first, so the circuit is being made in his hands instead of at the end of the stick.

  • @hootinouts
    @hootinouts ปีที่แล้ว +2

    I found a string of these yesterday on the ground in the woods about fifteen feet off a road a use every day. They look exactly like those they are working on and the porcelain disks are in pristine condition. The metal top on some are pitted from the weather but otherwise in good shape. here are six disks and a very rusted clamp with some heavy gauge stranded copper wire still in it. The poles that run along this road do not have these type of insulators so I figure at some time the utility company replace the old ones and the one I found was discarded. The disks are 10 inched in diameter. The ink under the glazing reads PINCO 1959-15000 lbs. I assume they were manufactured in 1959 and they are capable of resisting a 15000 lb load. Anyhow, I brought them home and cleaned them up. I have no idea what I will do with them but they are just too cool to have left in the woods.

    • @brucehadley69
      @brucehadley69 ปีที่แล้ว

      I also found a string of these in the woods, took them home but now don't know what to do with them. What did you end up doing with yours?

    • @brucehadley69
      @brucehadley69 ปีที่แล้ว

      @@Choukai_Kai oh wow thats quite a lucky find! Mine are identical to the ones in this video. What are you going to do with them?

  • @travis5543
    @travis5543 2 ปีที่แล้ว +3

    Crazy they make you wear rubbers while grounding and while working after it's grounded.

    • @ElectroTree01
      @ElectroTree01 ปีที่แล้ว +1

      I see why if you are doing it while grounding just in case human error or something but after I don’t really get it unless there is underbuild or something.

    • @Robmancan1987
      @Robmancan1987 6 หลายเดือนก่อน

      ​@@ElectroTree01Well you should always wear gloves while grounding because I've seen the line have enough static to draw an arc. Especially if the primary is close to a transmission line somewhere, the static can be crazy.

    • @ElectroTree01
      @ElectroTree01 6 หลายเดือนก่อน

      @@Robmancan1987 I agree, I've heard of that happening before but I guess I didn't think of it when writing the comment. I think you mean inductive coupling and/or capacitive coupling instead of static.

  • @johnfrancisgleason
    @johnfrancisgleason หลายเดือนก่อน

    Worker is on wrong side of jumper. Obviously their safety officer didn’t cover position while strapping was carrying the load.
    Could have been killed.
    This is a crew safety issue.

  • @internal_dialogue9290
    @internal_dialogue9290 5 หลายเดือนก่อน

    This might be the dumbest rigging I’ve witnessed to change s bell. Lucky you didn’t break another one, cut the rope and lose a phase. Please rig off the pole then lash your bells to the strap. Better luck next time.

  • @teresashinkansen9402
    @teresashinkansen9402 6 หลายเดือนก่อน

    Isn't it dangerous to be on that side of the line? (im not a line man just something that caught my attention) I mean if somehow the winch or the rope snaps the line falls and will pull you against and possibly out from the bucket.

  • @lewy1
    @lewy1 8 หลายเดือนก่อน

    Yes wearing gloves on a grounded line doesn’t make sense, but especially on 69kv as there are no gloves rated for that voltage. Also why didn’t they have a sling to the pole and attach the hoist to the sling.

  • @DonivanSalazar
    @DonivanSalazar 4 หลายเดือนก่อน

    Next time when you record something like this make sure not to post it sorry but the only thing i got out of this video was a few laughs

  • @internal_dialogue9290
    @internal_dialogue9290 5 หลายเดือนก่อน

    I got dumber watching you tie what is supposed to be a knot.

  • @edge1289
    @edge1289 ปีที่แล้ว +1

    Knot tying skills leave something to be desired. Apparently you don’t have nylon strap slings or a becket to wrap around the bell. The sling should be set up so the hook of the puller rides between the bells so you don’t break the porcelain on the bell you’re attached to. Other than that, not bad for a first year apprentice.

    • @ElectroTree01
      @ElectroTree01 ปีที่แล้ว

      The crews here sometimes carry slings. I get what you mean by that.

  • @DerekHundik
    @DerekHundik 4 ปีที่แล้ว +4

    so basically the whole thing is hold by few pins

    • @electron2601
      @electron2601 3 ปีที่แล้ว +2

      Actually no, there's a ball or clevis and that supports tye weight. The cotter pin he took out just holds those together so they don't shift out.

    • @hootinouts
      @hootinouts ปีที่แล้ว

      @@electron2601 Correct

  • @internal_dialogue9290
    @internal_dialogue9290 5 หลายเดือนก่อน

    Shitshow from start to finish. The End.

  • @paulbaker3611
    @paulbaker3611 7 หลายเดือนก่อน

    A striking example of how not to do work.

  • @DetlefBertz
    @DetlefBertz 2 หลายเดือนก่อน

    Ich arbeite selber in dem Job zu blöd eine E und K einzubauen
    Einen Splind aus dem VK 60 zu ziehen u.s.w.

  • @thereview32
    @thereview32 10 หลายเดือนก่อน

    Not how I would’ve done the job, but do you Tex

  • @ВладимирБеловодский
    @ВладимирБеловодский 3 หลายเดือนก่อน

    За такую работу у нас выгоняют

  • @Faaaaaaaaaaaaz
    @Faaaaaaaaaaaaz 2 ปีที่แล้ว +1

    While fixing one, breaking others... They are very fragile, don't hit them

    • @ElectroTree01
      @ElectroTree01 ปีที่แล้ว

      My experience with porcelain is if you expect it to break it probably won’t but when it touches itself in a harmless way it explodes.

  • @whistlermtn7
    @whistlermtn7 2 ปีที่แล้ว +1

    Can't tie a knot, tie alot

  • @Tokencaucasian
    @Tokencaucasian 8 วันที่ผ่านมา

    Why the gloves

  • @internal_dialogue9290
    @internal_dialogue9290 5 หลายเดือนก่อน

    Pull cotter key on ball Clovis when there is still strain. Comes right out.

  • @marcoquiroz2307
    @marcoquiroz2307 2 ปีที่แล้ว +1

    Se tiene que anclar del poste para cambiar el aislador quebrado

  • @internal_dialogue9290
    @internal_dialogue9290 5 หลายเดือนก่อน

    “ you godda bail?” 😂

  • @lendavidhart9710
    @lendavidhart9710 5 ปีที่แล้ว +2

    Hi thanks for posting, why do you connect the phases together?
    And arent those called petty coat insulators. Thnks again for posting.

    • @jonwillard3198
      @jonwillard3198 3 ปีที่แล้ว

      They grounded the lines to work on them . Non energized lines , grounded just in case they became energized.

    • @sknirav4053
      @sknirav4053 3 ปีที่แล้ว

      @@jonwillard3198 how did he grounded it... He just connected 2 phases right?? Or one of them is neutral line?

    • @randacnam7321
      @randacnam7321 3 ปีที่แล้ว

      @@sknirav4053 There is another bonding jumper going to the top phase that is out of shot.

    • @johnblair8146
      @johnblair8146 9 หลายเดือนก่อน

      No, they aren't petticoat insulators. Petticoat insulators are the pin type insulators mounted on top of crossarms.

  • @billyjosen1456
    @billyjosen1456 4 หลายเดือนก่อน

    🤨🫣

  • @luisalbertogonzalez-yj1pw
    @luisalbertogonzalez-yj1pw ปีที่แล้ว

    No pueden mostrar este trabajo esta mal hecho puesta tierra es una risa cuando la colocan deben asesorarse ante de hacer esto.

  • @petrdlouhy3439
    @petrdlouhy3439 3 ปีที่แล้ว +1

    Awesome 🙂👍💪

  • @discountsnowstakes7360
    @discountsnowstakes7360 3 ปีที่แล้ว +1

    Nice job

  • @linehandibew6205
    @linehandibew6205 11 หลายเดือนก่อน

    Rubber gloves on a grounded line….makes sense

  • @powerlinekidforsman9360
    @powerlinekidforsman9360 4 ปีที่แล้ว +1

    those are thick insulators

    • @thelast1900
      @thelast1900 2 ปีที่แล้ว

      There suspension insulators i think

  • @bryanwilliams4343
    @bryanwilliams4343 11 หลายเดือนก่อน

    Where do they find them at

  • @ramniwasverma567
    @ramniwasverma567 ปีที่แล้ว

    Good work

  • @s.nelectricalelectricalmac1545
    @s.nelectricalelectricalmac1545 3 ปีที่แล้ว

    Pole is wood😃😃😃

  • @cherishkenny3237
    @cherishkenny3237 2 ปีที่แล้ว

    Bird gard

  • @cherishkenny3237
    @cherishkenny3237 2 ปีที่แล้ว

    115kv

  • @venomdestructor6262
    @venomdestructor6262 ปีที่แล้ว

    OMG Dumb and dumber!!!!!!! It hurt my eyes 😁😁😁😁😁🙆🙆🙆🤦🤦🤦