Electric work external karvana jyada sahi hai ya internal , isliye kyuki mere landlord ne jab internal electric fitting jarvaayi thi tab usne AC ki wire nahi daali thi baad me AC ki wire dalne ki jagha hi nahi bachi fir usko outer karni padi
Sir, mujhe Aap ki video se kafi kuch sikhne ko milta h. Par 1 sawal h, agar earthing karun, to RCCB kam nhi karega. Jabki RCCB bahut zada important hota 1 ghar ke liye, jo shoke lagne se bachata h. Iska kya solution h ....?
🙏🏼✨Hello Ji Dearest'S Hoping Ji You All Are Doing Wonderful Ji 🤲🙏🏼 May God Ji Always Blessess You All Ji 🤲🙏🏼May You All The Universe'S Ji Achieve So Much In Your Life 💫💫🙏🏼We All Are Here With You All Ji So So Ji Proud Of You All Ji🤲🙏🏼🤲🙏🏼Keep Going Ji Respected Person'S Ji Thank You So Very Much Ji 💫🙏🏼So So Sorry Ji 🙏🏼💫May God Ji ALWAYS BLESSESS YOU ALL JI 🙏🏼💫Keep Going Ji-Random Person🤲🙏🏼
🙏🏼✨Hello Ji Dearest'S Hoping Ji You All Are Doing Wonderful Ji 🤲🙏🏼 May God Ji Always Blessess You All Ji 🤲🙏🏼May You All The Universe'S Ji Achieve So Much In Your Life 💫💫🙏🏼We All Are Here With You All Ji So So Ji Proud Of You All Ji🤲🙏🏼🤲🙏🏼Keep Going Ji Respected Person'S Ji Thank You So Very Much Ji 💫🙏🏼So So Sorry Ji 🙏🏼💫May God Ji ALWAYS BLESSESS YOU ALL JI 🙏🏼💫Keep Going Ji-Random Person🤲🙏🏼
Sir mere electrician ne earthing plate wali Kari hai coal or salt daal k jo process hoti hai phir usne 100 watt ka bulb jala k dikha dia tha ki bulb full jaega to proper earthing hai, ohms me value kese nikale, net pe check kra to 100 watt ka 8 ohms bta Raha hai,
earthing meter aata hai usse check kar lo, accurate reading pata chal jayega. 3-5ohm hi sahi earthing hoti hai, agar 5ohm se jada value hai to fir se earthing karwo kyu ki safety point of view se bilkul galat hai and shock lagne ka kharta bana rahega.
transformer ki earthing transformer ke liye hoti hai n ki tumhare ghar ke liye. earhing ka kaam hota hai agar neutral fail ho jaye to safe path provide kar sake charge ko, matlab agar ghar me khai kissi electronics ya board me phase short ho jaye to current earthing wire se earth me chale jaye aur user ko current n lage aur mare nahi.
Electric work external karvana jyada sahi hai ya internal , isliye kyuki mere landlord ne jab internal electric fitting jarvaayi thi tab usne AC ki wire nahi daali thi baad me AC ki wire dalne ki jagha hi nahi bachi fir usko outer karni padi
Mai apki video 6 month se dekh rha hu kafi help hoti hai
Thanks Sir
thank you patel sahad
share b karna zarur ♥️
बहुत ही सुन्दर सुझाव
Sir, mujhe Aap ki video se kafi kuch sikhne ko milta h.
Par 1 sawal h, agar earthing karun, to RCCB kam nhi karega. Jabki RCCB bahut zada important hota 1 ghar ke liye, jo shoke lagne se bachata h.
Iska kya solution h ....?
Thank you Civil site visit, good effort, keep it like this so far.
17:07 Apne AC ke fitting charges ke baare me nahi bataya
Pls share video on earthing as well. Thks
Xbhai yeh bata rhe ho construction k hisaab se agr chota kaam h ek bad room ka sirf to 700 bohot km h
Thank you so much Sir jee 🙏🙏
Poly cab me ab bohot quality h me ab RRk wier use krta hu
Very good video 🎉
Good information bhai
🙏🏼✨Hello Ji Dearest'S Hoping Ji You All Are Doing Wonderful Ji 🤲🙏🏼 May God Ji Always Blessess You All Ji 🤲🙏🏼May You All The Universe'S Ji Achieve So Much In Your Life 💫💫🙏🏼We All Are Here With You All Ji So So Ji Proud Of You All Ji🤲🙏🏼🤲🙏🏼Keep Going Ji Respected Person'S Ji Thank You So Very Much Ji 💫🙏🏼So So Sorry Ji 🙏🏼💫May God Ji ALWAYS BLESSESS YOU ALL JI 🙏🏼💫Keep Going Ji-Random Person🤲🙏🏼
Great
🙏🏼✨Hello Ji Dearest'S Hoping Ji You All Are Doing Wonderful Ji 🤲🙏🏼 May God Ji Always Blessess You All Ji 🤲🙏🏼May You All The Universe'S Ji Achieve So Much In Your Life 💫💫🙏🏼We All Are Here With You All Ji So So Ji Proud Of You All Ji🤲🙏🏼🤲🙏🏼Keep Going Ji Respected Person'S Ji Thank You So Very Much Ji 💫🙏🏼So So Sorry Ji 🙏🏼💫May God Ji ALWAYS BLESSESS YOU ALL JI 🙏🏼💫Keep Going Ji-Random Person🤲🙏🏼
Sir ciling fen me Arthing krna chahiye ya nhi?
Kya Overall Complete House Ke Liye 4 mm Wire Ka Used Kar Sakte Hai...??
haan, koi problem nahi hogi, balki ye best rahega.
lekin cost thoda jada hoga wiring ka.
👍👍👍
Wiring kaun se company ki lagaye, ye to batao Sir
Anchor is best less price good material
Wire havells ke use kro
Plaza company FRLS wires are best for house electric fitting.
Havells
Havells
Sir mere electrician ne earthing plate wali Kari hai coal or salt daal k jo process hoti hai phir usne 100 watt ka bulb jala k dikha dia tha ki bulb full jaega to proper earthing hai, ohms me value kese nikale, net pe check kra to 100 watt ka 8 ohms bta Raha hai,
earthing meter aata hai usse check kar lo, accurate reading pata chal jayega.
3-5ohm hi sahi earthing hoti hai, agar 5ohm se jada value hai to fir se earthing karwo kyu ki safety point of view se bilkul galat hai and shock lagne ka kharta bana rahega.
Earthing to transformer me laga hota hai fir kyu earthing karna alag se
transformer ki earthing transformer ke liye hoti hai n ki tumhare ghar ke liye.
earhing ka kaam hota hai agar neutral fail ho jaye to safe path provide kar sake charge ko, matlab agar ghar me khai kissi electronics ya board me phase short ho jaye to current earthing wire se earth me chale jaye aur user ko current n lage aur mare nahi.
square mm not sqare mtr
Aartig ka bhi video banana sir
earthing hota hai wo.
Square metre Nehi square millimetre hota he.
In odisha electric switch point is 100
Kya aap yeh kaam karwa sakte ho?
Itne sare cheeze kon yaad rakega
❤
Earthing ka vdo bnao