HOW TO IDENTIFY 6 LEADS 3 PHASE MOTOR WITHOUT MARKING and COLOR CODE - PINOY

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ม.ค. 2025

ความคิดเห็น •

  • @franztinevlog9728
    @franztinevlog9728 ปีที่แล้ว

    thanks master may bago na naman akong kaalaman god bless master

  • @ferdinandbalino2746
    @ferdinandbalino2746 9 หลายเดือนก่อน

    Thanks!

  • @raulacbo4469
    @raulacbo4469 2 ปีที่แล้ว

    Thank you so much master isa kang malaking nag babagahi ng iyung kaalaman. at higit nakaka tulong sa aming mga new electrician. mabuhay po kayo.

    • @masterpinoyelectrician
      @masterpinoyelectrician  2 ปีที่แล้ว +1

      Salamat master sa iyong pag-suporta dito sa ating channel. paki-share na lang po ito sa iba.

  • @WilsonClarito-gl1hd
    @WilsonClarito-gl1hd 5 หลายเดือนก่อน

    Mahusay po kau magpaliwanag. Salamat po sa video tutorial nyo po. Godbless.

    • @masterpinoyelectrician
      @masterpinoyelectrician  5 หลายเดือนก่อน

      Salamat sir, pakishare na lang ito sa iba. God bless.

  • @michaelmalinao1303
    @michaelmalinao1303 3 ปีที่แล้ว

    Maraming salamat sa dagdag kaAlaman

  • @UnitFerminBDauag
    @UnitFerminBDauag ปีที่แล้ว

    napanood ko at siguradong akong tama

  • @jonathanabainza5876
    @jonathanabainza5876 3 ปีที่แล้ว

    SALAMAT SA KAALAMAN AT TIPS SA PAG TROUBLE SHOOTING

  • @renzofficial2435
    @renzofficial2435 2 ปีที่แล้ว

    nice tutorial master sir mabuhay po kayo

  • @bonifaciomapajr.4411
    @bonifaciomapajr.4411 10 หลายเดือนก่อน

    Salamat po sir

  • @eduardandrademixvlog2292
    @eduardandrademixvlog2292 ปีที่แล้ว

    Salamat po ulit idol

  • @canad900
    @canad900 2 ปีที่แล้ว

    Maganda makasama ko kayo sa trabaho sir, may matutunan sana ako.. ❤

    • @masterpinoyelectrician
      @masterpinoyelectrician  2 ปีที่แล้ว +2

      ok master, no problem suportahan kita, ito ngang ibang lahi na palagi ko nakakasama dito sa trabaho kahit hindi ko tinuturan ay natututo sa akin, mahusay kc silang mangggaya, nakikita nila ang ginagawa ko.

  • @dennisdumalag8242
    @dennisdumalag8242 3 ปีที่แล้ว

    Salamat sir!

  • @karlpagaran8814
    @karlpagaran8814 2 ปีที่แล้ว

    goodmorning po

    • @masterpinoyelectrician
      @masterpinoyelectrician  2 ปีที่แล้ว +1

      Magandang buhay master, welcome po. Salamat sa iyong suporta dito sa ating channel.

  • @narendergodara1992
    @narendergodara1992 ปีที่แล้ว

    Excellent vedio👌👌

  • @albertoelchico1477
    @albertoelchico1477 2 ปีที่แล้ว

    very informative sir.more videos pa sur 💕💕💕💕

    • @masterpinoyelectrician
      @masterpinoyelectrician  2 ปีที่แล้ว +1

      Thank you sir, may bago na po ulet tayong upload na video, pakibisita na lang po ang ating channel, at paki-share po ito sa iba. Salamat ulet sir.

  • @AngelGarcia-pl9sv
    @AngelGarcia-pl9sv 2 ปีที่แล้ว

    newbie subscriber master..any tips po sa interview bilang electrician abroad.thanks

    • @masterpinoyelectrician
      @masterpinoyelectrician  2 ปีที่แล้ว +1

      Salamat sa iyong suporta master dito sa ating channel. paki-click na lang ng link para sa ilang mga tips and idea about interview abroad. Paki-share na lang po sa iba itong ating channel, Thanks po God Bless.
      INTERVIEW ABROAD NG ARABO.
      th-cam.com/video/hMlWSLmFOmo/w-d-xo.html
      TRADE TEST FOR ABROAD
      th-cam.com/video/_2BKrvQ-XYQ/w-d-xo.html
      MASTER PINOY ELECTRICIAN CHANNEL
      th-cam.com/channels/eWZ7EMIao7Ters3zR6WF8w.htmlvideos

  • @UnitFerminBDauag
    @UnitFerminBDauag ปีที่แล้ว

    kung marunong ka sa connection sa pag re-rewind ay madali molang makuha ang start at end

  • @ManuelRamos-f6j
    @ManuelRamos-f6j ปีที่แล้ว +1

    Master paano po mag terminate ng 440v 12leads sa terminal box pero 3leads out nlng ang lalabas papuntang VFD.
    W5 u5 v5
    W2 u2. V2
    W6 u6 v6
    U1 v1 w1
    Ito po master ung nka tagging

    • @masterpinoyelectrician
      @masterpinoyelectrician  ปีที่แล้ว

      Series delta connection sir, 440V supply. Kunan mo muna resistance sir U1 at U2 to make sure na yan ung end to end ng winding. Ganoon din ung U5 at U6. At maging sa V1 at V2, W1 at W2 at sa iba pang natitirang leads. Iseries mo lang sir, Delta connection.
      Line 1 - U1 at W6 .
      Line2 - V1 at U6,.
      Line3 - V6 at W1.
      connected together
      U2 at U5 ,
      V2 at V5 .
      W2 at W5

  • @RosaschannelOFW
    @RosaschannelOFW 3 ปีที่แล้ว

    great tutorial god bless master

  • @UnitFerminBDauag
    @UnitFerminBDauag ปีที่แล้ว

    pinaka mabuti ay pag aralan mo muna ang pag re-rewind bago mo ma master ang connction kahit walang marking

  • @ArvinCastilla
    @ArvinCastilla 7 หลายเดือนก่อน

    Sri panu po kaya pag wala taging submersible pump 6lead terminal pnu po ikonekta sa wye delta

    • @masterpinoyelectrician
      @masterpinoyelectrician  7 หลายเดือนก่อน +1

      Master may isa pa tayong tutorial tungkol dyan sa iyong tanong. Paki check na lang po sa mismong channel, sa mga videos. Salamat master. God bleas.

  • @ulysiscorpuz929
    @ulysiscorpuz929 6 หลายเดือนก่อน

    Master kapag po ba 2 delta 220v 3phase 12leads motor, dalawa po ba aang supply nito,? Sa OL. At delta po ba ang supply?

    • @masterpinoyelectrician
      @masterpinoyelectrician  6 หลายเดือนก่อน

      Master, 12leads, 2Delta parallel, 3Phase 220V. Mayroon tayong tutorial nito sir, paki-check na lang po sa ating channel. Salamat po. God bless.

  • @mjbanaresconstructionandge176
    @mjbanaresconstructionandge176 4 หลายเดือนก่อน

    Boss magandang hapon po sa inyo, patulong po pano ikabit ang wiring ng electric motor ko sa 3 phase genset

    • @masterpinoyelectrician
      @masterpinoyelectrician  4 หลายเดือนก่อน +1

      Master, mag install ka ng sub-breaker connected dyan sa main breaker ng genset mo. Sa sub-breaker mo iconnect yang control panel mo para dyan sa iyong ac motor.

  • @pansitkanton1881
    @pansitkanton1881 2 ปีที่แล้ว

    Master new subscriber po ako . Ibig sabihin po ba nito base dito 10:08 Pwede pong magbaliktad ang pag terminate basta magkasama ang ending winding at magkasama ang starting winding, dahil hindi po mag oopose ang voltage nila? For example po in Wye Connection, Ang mga ending winding ang nai-connect mo sa control tapos ang napag-sama mo is yung mga starting winding. Ibig sabihin gagana po ito, ganun po ba yon master? Sana masagot po master ❤

    • @masterpinoyelectrician
      @masterpinoyelectrician  2 ปีที่แล้ว

      Master, paki-review ng tutorial video natin from part1 and part2 nasa discription box ang link. pakitapos lang po ang video. Salamat.

  • @robertoviana4215
    @robertoviana4215 3 ปีที่แล้ว

    Salamat Master sa video...ask ko lang po yan po pinapapaliwanag nyo d2 ay sa wye connection...bago lang po ako sa motor control ...ask ko lang po Master...di po ba pede iconnect na lang yun motor ng wye delta configuration para lahat ng lead magagamit at mas madali hanapin yun designated lead...salamat po

    • @masterpinoyelectrician
      @masterpinoyelectrician  3 ปีที่แล้ว +1

      Magandang buhay sir, pwede naman po yan, iwasan lang po ang pagkalito lalo pat may time pressure sa trabaho. Salamat po, paki-share na lang po sa iba.

  • @democracioulep3408
    @democracioulep3408 ปีที่แล้ว

    Paano po malalaman ang bigining point at ending point ng winding ng induction motor?

    • @masterpinoyelectrician
      @masterpinoyelectrician  ปีที่แล้ว +1

      ito sir ang isa nating video tutorial tungkol dyan, paki click na lang po baka makatulong, Salamat master.
      th-cam.com/video/k9GVFGXCchU/w-d-xo.html

  • @robertsartiga6166
    @robertsartiga6166 2 ปีที่แล้ว

    Master paano ba pataasin ang hertz nagpalit na ako avr hang fifthy lang dapat sixty ano dapat kong gagawin salamat po

  • @boyetmelgar
    @boyetmelgar 2 ปีที่แล้ว

    sir 9 leads po paano po mag wiring pati po yng value ng run at start capacitor abb 5.5 hp po sya induction motor. 3 phase po sya gagamitin sa single phase

  • @marlouormides6461
    @marlouormides6461 2 ปีที่แล้ว

    Sir gd am po ask kolang po kung pwede ma revers forwad ang single phase motor 4leads r

  • @arnelgallano2911
    @arnelgallano2911 2 ปีที่แล้ว

    Good pm master.. Tanong ko lng po.. Kung ang six lead n wye delta... Pd ko b gawin if wala kmi spare na six lead.. Pd ko b gamitin ung 3lead. At gagawin ko muna d. O. L 380v 3phase

    • @masterpinoyelectrician
      @masterpinoyelectrician  2 ปีที่แล้ว

      Master, meon po tayong tutorial nyan, paki-click na lang po ang link.
      THEORY
      th-cam.com/video/Y6NJOIq1LYw/w-d-xo.html
      ACTUAL
      th-cam.com/video/OptSKydfbK4/w-d-xo.html

  • @ajbtv5727
    @ajbtv5727 2 ปีที่แล้ว

    Boss sa pg rerewind ng motor..paano mo malalaman na yung blocking diagram mo sa data mo is tama or mali..salamat po

  • @jaykesapalaran5434
    @jaykesapalaran5434 2 ปีที่แล้ว

    master pwede ba gamitan ng DC volt battery at LED LIGHT para malaman Yung polarity + & - ng windings???

    • @masterpinoyelectrician
      @masterpinoyelectrician  2 ปีที่แล้ว

      Yes master pwd po, si Rosenberg may tamang procedure para dyan lalo na sa 9 leads out.
      Sa tutorial ko po kc dito at sa actual na sitwasyon ay wala na pong oras para gawin yan, lalo pat nagmamdali ang site engr. yan na po ang mabilis na paraan para maiconnect kaagad at mpagana ito ng tama. Salamat master sa iyong suporta. paki-share po ito s iba.

    • @jaykesapalaran5434
      @jaykesapalaran5434 2 ปีที่แล้ว

      Walang anoman master..
      Salamat din sa mga video tutorial mo...laking tulong sa Amin.

  • @owshiee
    @owshiee ปีที่แล้ว

    Sir pano kung tama po rotation pero high ampere?

    • @masterpinoyelectrician
      @masterpinoyelectrician  ปีที่แล้ว +1

      Dapat master ay tugma ang connection ng motor sa supply voltage.

  • @sailorenzo2812
    @sailorenzo2812 ปีที่แล้ว

    Master paano ko po MA identify Kung unmarked Yong 3 wires na Naka labas. Wla pong terminal box sa labas. Alin ba doon sa tatlo ang T1, T2 or T3.

    • @masterpinoyelectrician
      @masterpinoyelectrician  ปีที่แล้ว +1

      Kung meron kang phase sequence meter or phase rotation meter madali mong maidentify ang tamang leads ng t1, t2, at t3 para sa tamang phasing pero kung wala at mali ang rotation ng motor pagbaliktarin mo lang alinman dyan sa t1 and t2 or t2 and t3 or t3 and t1

    • @sailorenzo2812
      @sailorenzo2812 ปีที่แล้ว

      Maraming salamat po master. God bless and more luck to you.

    • @masterpinoyelectrician
      @masterpinoyelectrician  ปีที่แล้ว +1

      Salamat master, keep safe and God bless.

  • @markangelocaban915
    @markangelocaban915 ปีที่แล้ว

    Salamat sir, pero tanong ko lang sir ppano kung ang na connect mo sa wye config ay ang T1, T2 ,T3, at ang nsupplyan ng L1,L2,L3 ay ang T4,T5,T6, gagana po bah? Kasi nga nag trial and error ang procedure nito..

    • @masterpinoyelectrician
      @masterpinoyelectrician  ปีที่แล้ว

      Gagana yan master, kahit ung L1,L2, L3 ay maiconnecta sa t4,t5,t6, Ang importante sa lahat master ay Tama ang nort pole at south pole leads ng mga windings.

    • @markangelocaban915
      @markangelocaban915 ปีที่แล้ว

      @@masterpinoyelectrician ah ok sir maraming salamat sa pag reply, GODBLESS.

  • @UnitFerminBDauag
    @UnitFerminBDauag ปีที่แล้ว

    mag download ka ng EKTS para ma practice mo ang connection

  • @jonardcastanon4740
    @jonardcastanon4740 2 ปีที่แล้ว

    Pano po kung y ay naka on at delta naka on pwede ba mag sabay in seperate contactor? Please

    • @masterpinoyelectrician
      @masterpinoyelectrician  2 ปีที่แล้ว +1

      Master Jonard, paki-click ng link, andyan ang kasagutan sa iyong katanungan. pak-share na lang itong ating channel sa iba. Salamat master.
      th-cam.com/video/M3gQZDDwoZ4/w-d-xo.html
      th-cam.com/video/hMlWSLmFOmo/w-d-xo.html

  • @jhunragot3361
    @jhunragot3361 ปีที่แล้ว +1

    Sir master Sabi mo pag Mali ang polarity Ng beginning At ending baliktarin Lang. Paano Kung ang baliktad at 3 leads T1, T2, T3 ay naging 4,5,6 iikot ba?
    Paano Kung ang baliktad at 2 Lang ? So baliktarin ko ang isa pag Hindi parin umikot Yung isa uli pero dahil Hindi ko alam ang nabaliktad ko ay ang tama Hindi parin iikot. So ano ang gagawin? Salamat master Sana mabigyan mo ako ng kasagutan.

  • @anthonymarkyorac4314
    @anthonymarkyorac4314 2 ปีที่แล้ว

    Master anu po yong voltahi po?

  • @jemelsacopon1099
    @jemelsacopon1099 ปีที่แล้ว

    sir good afternoon I have a question...if the t1 t2 t3 mark is not there and the wire is the same color..I just want to ask after getting the winding together..how will I know which of the two is there the t1 and t4 or the start and out winding..what do I need to do to make it easier for me to know..thank you for your answer sir. just a beginner as an electrician..thank you

    • @masterpinoyelectrician
      @masterpinoyelectrician  ปีที่แล้ว +2

      I am planning to make one more video about that, so stay tune. thanks and God bless

  • @edgarlagumbay1266
    @edgarlagumbay1266 3 ปีที่แล้ว

    Sir good day po pede po makahingi ng diagram ng three phase two speed motor ,thanks po

    • @masterpinoyelectrician
      @masterpinoyelectrician  3 ปีที่แล้ว +2

      Good day master, two speed motor leads connection and controller lang po, Single winding and two winding for Constant torque and Variable torque.

  • @Mechanics_world007
    @Mechanics_world007 ปีที่แล้ว

    Malinaw po ang pagkakapaliwanag sir,thank you po sir for sharing

    • @masterpinoyelectrician
      @masterpinoyelectrician  ปีที่แล้ว +1

      Welcome master at salamat rin sayong suporta. Paki share na lang sa iba itong ating channel.

  • @jhunragot3361
    @jhunragot3361 ปีที่แล้ว

    14: 14:50 50

  • @anamaypatil8804
    @anamaypatil8804 8 หลายเดือนก่อน

    which language you are talking

  • @jay-arzuniga5563
    @jay-arzuniga5563 18 วันที่ผ่านมา

    Katakot baka Sumabog

  • @DharmendraKumar-qq8wv
    @DharmendraKumar-qq8wv 3 ปีที่แล้ว

    Hindi me video banay

  • @rodolfosabado3752
    @rodolfosabado3752 7 หลายเดือนก่อน

    Dko maintindihan sir yung drawing

  • @jetvon3478
    @jetvon3478 ปีที่แล้ว

    Thank you po Sir ..

    • @masterpinoyelectrician
      @masterpinoyelectrician  ปีที่แล้ว +1

      Salamat din sayo master. Paki share na lang sa iba itong ating channel.