*Timestamp for my personal use:* @1:10 Ongrid net meter connection explanation @5:00 Net meter connection diagram shown. @8:45 OffGrid diagram explained
Net meter is stayed at net meter readingshowing not moving continue there are 2 black knobs and not blinking today meter reading took reading and left at stage on net reading now it is constant not moving permanently pl advice me how to run for further reading
नया सोलर 4kw का प्लांट लगा है, अभी net metering नहीं हुई है। तो क्या सोलर इन्वर्टर बिजली बना देगा, और यह इन्वर्टर में दिखाई देगी। यदि बिजली बनती है तो इसे घर के लोड के रूप में प्रयोग कर सकते हैं या नहीं। Goodwe का इन्वर्टर है।
No nothing algorithm is there, there is no priority either. It's working on electricity principle. Let's take an example when inverter is producing 1000 w and house load is 1100 w then it will draw (import) 100 w from grid, in case when inverter is generating same 1000w and house load is 100w where the extra 900w will go? Simple it will flow(injected) towards grid. And in case when inverter generation is 1000w and house load is also 1000w then there will be zero import and export. Hope this clarifies your query.
Nahi sir, MCB on karne ke baad inverter 120 second leta hai synchronization ke liye uske baad hi bijli deta hai. Do consider subscribing my channel thanks.
मेरे को एक बात खाई जा रही हैं की अगर आप सोलर से निकली हूई बिजली को नेट मिटर के आऊट पुट सप्लाई में देते हैं, समज लो की mecb की सप्लाई चली जाती है, तो सप्लाई नेट मिटर के जरीय mecb में जाती है क्या
नहीं भाई जैसे ही आपकी ग्रिड की सप्लाई फैल होगी उसी समय सोलर भी बिजली बनाना बंद कर देगा। ऑन ग्रिड चलने के लिये ग्रिड की सप्लाई अनिवार्य है और केवल रेफरेंस वोल्टेज के लिये जिस के हिसाब से सोलर प्लांट बिजली बनायेगा। आशा करता हूँ कि आपको आपके प्रश्न का उत्तर मिल गया होगा।
Netmeter लगाकर सोलर डेली कितना यूनिट बना रहा है l देख सकते हैं कि नहीं l चार्ज कंट्रोलर तो बताते रहता है l पर हाइब्रिड इनवर्टर में यूनिट show नहीं करते हैं l यूनिट कैसे देखे बताए l
Yes for this you have to approach your local discom office for getting records of smart meter updates to net smart meter .then it will be giving both export and import of power
मेरे प्रश्न का कोई एक्सपर्ट उत्तर नहीं दे पा रहा, आप से उम्मीद है आप de पायेंगे। दिन के समय सोलर की बिजली डायरेक्ट कंज्यूम करते हैं कया वो कंज्यूम की हुई बिजली की काउंटिंग इंपोर्ट यूनिट्स में होती है या कहीं भी काउंट नही होती। इंपोर्ट के थ्रू आने वाली बिजली को ग्रीड की बिजली माना जाता है अगर डायरेक्ट कंज्यूम की हुई बिजली इंपोर्ट यूनिट्स में काउंट होती है तो ये मेरे हिसाब से गलत है। सार में मेरा प्रश्न है डे लोड ज्यादा होने पे डायरेक्ट कंज्यूम की हुई बिजली को कौन सा मीटर काउंट करता है।? एक और प्रश्न, सोलर से आने वाली AC wire को net मीटर के inward साइड पे लगाते हैं या आउटवार्ड साइड, या कोई अलग प्वाइंट होता है, अगर आउट पे लगाते हैं तो दो अलग दिशाओं से आने वाली बिजली का शॉर्ट क्यूं नही होता। कृपया प्रकाश डालें। धन्यवाद।
Mere ghar me lga hai kuch din phle. Lekin solar meter nhi lagaya hai. Net meter laga hua hai. Lekin system yani invertor kam nhi kar raha hai. Fault bata raha hai.
Complete connection kar ke chala gya tha but net meter oos time nhi laga tha. To government electricity wale Aa kar lga kar chale gye net meter bad me. Solar wala acdb se 2 wire nikal kar chora hua tha main mcb me lagane ke liye. To wo wire joint hone par bhe invertor work nhi kar raha hai faut Aa rha h display me. Solar wale se bat hua wo aayega 2 din me. Shayad invertor me problem hai
@@fmkhan84 ho gya bro start ho gya. Wo technician ke galti the jo wire invertor ke out put se nikalta h 1 plastic ke holder ss jisme 3 wire hota h greee, black, red usme wo mistake kiya tha. Usko mai khud sahi kiya. Call krke solar company me.wo wire acdb se joint hota h. Fir acdb se nikal kr 2 wire main mcb ke out me joint kr diya to chalu ho gya. Fault ab nhi h. Running show kr rha. 2000 se 2200 kbhi 2300 watt tak generate kr rha h pannel show kr rha h invertor ke display me. Smart meter lga hua h.
*Timestamp for my personal use:*
@1:10 Ongrid net meter connection explanation
@5:00 Net meter connection diagram shown.
@8:45 OffGrid diagram explained
My doubts got cleared after watching complete video. Thanks sir, u are doing a great job.
Extremely well explained. This diagram is was I was looking for.
In a Hybrid Inverter the diagram is the same, but the load is taken from the hybrid inverter instead of main grid ?
Sir ji inverter me AC input hota hai wo kaha se connect karna hai?
Kyuki aapne diagram me to inverter ka AC output and solar input hi bataya hai.
Market se net meter parchage karne ke baad kya direct discom ke meter ko replace karke net metering service chalu ho sakti hai kya
Net meter is stayed at net meter readingshowing not moving continue there are 2 black knobs and not blinking today meter reading took reading and left at stage on net reading now it is constant not moving permanently pl advice me how to run for further reading
Without electricity work karega ya nahin
Thanks for your video i like it sir to your information 😀 I am happy
Channel subscribe to kar lete
प्रिय दर्शकों, आपके नेट मीटर से ज़ुड़े सभी सवालों के जवाब इस वीडियो में मैंने दिये हैं। th-cam.com/video/zgy26Clw_xA/w-d-xo.html Happy Learning....
Is solar meter necessary in the system
नया सोलर 4kw का प्लांट लगा है, अभी net metering नहीं हुई है। तो क्या सोलर इन्वर्टर बिजली बना देगा, और यह इन्वर्टर में दिखाई देगी। यदि बिजली बनती है तो इसे घर के लोड के रूप में प्रयोग कर सकते हैं या नहीं। Goodwe का इन्वर्टर है।
Is any app for solar net meter please help
sir 3 phess me solal meter hota hai kay
Hota hai
Net meter output m agar solar k ac output milange to spark ho jaega
नहीं
3 phase digital meter pr net metering ki jaa skti hai?
Ji bilkul ki ja sakti hai aur hoti bhi hai
@@TheFutureIsSolar lekin hum phr kese dekhen gy readings jo humne bheji hain grid ko?
@@TheFutureIsSolar mere pas green meter bi-directional nhi hai
@@Syed_Saad_Shah_Abidi bina bidirectional meter ke bina ongrid ka koi meaning nahi hai
In this connection how to also connect sub meter for tenant.
Need a separate meter from discom your electricity board
Well explained
Thanks for your appreciation. Consider subscribing the channel.
Hi sir,why load gives first priority to solar,is it there any algorithm in inverter
No nothing algorithm is there, there is no priority either. It's working on electricity principle. Let's take an example when inverter is producing 1000 w and house load is 1100 w then it will draw (import) 100 w from grid, in case when inverter is generating same 1000w and house load is 100w where the extra 900w will go? Simple it will flow(injected) towards grid. And in case when inverter generation is 1000w and house load is also 1000w then there will be zero import and export. Hope this clarifies your query.
Great sir
Jbb apne solar AC line or Meter Grid AC line ko loop krte h ...top dono m spark nhi hota???
Nahi sir, MCB on karne ke baad inverter 120 second leta hai synchronization ke liye uske baad hi bijli deta hai. Do consider subscribing my channel thanks.
@@TheFutureIsSolar acchaa... frequency match ho jati h toh...koi spark nhi hogaa🙏👍👍
Good helpful video
Sir I have one doubt please try to make it easy for me please give arrow to wires which way current flows
Ok sir in my next Video I'll show. Thanks
Aapke liye ek video banaya hai. Aap use dekhe clear ho jayega
मेरे को एक बात खाई जा रही हैं की अगर आप सोलर से निकली हूई बिजली को नेट मिटर के आऊट पुट सप्लाई में देते हैं, समज लो की mecb की सप्लाई चली जाती है, तो सप्लाई नेट मिटर के जरीय mecb में जाती है क्या
नहीं भाई जैसे ही आपकी ग्रिड की सप्लाई फैल होगी उसी समय सोलर भी बिजली बनाना बंद कर देगा। ऑन ग्रिड चलने के लिये ग्रिड की सप्लाई अनिवार्य है और केवल रेफरेंस वोल्टेज के लिये जिस के हिसाब से सोलर प्लांट बिजली बनायेगा। आशा करता हूँ कि आपको आपके प्रश्न का उत्तर मिल गया होगा।
@@Vijay_Agrawal Ji sir you can go for hybrid. Combination of off-grid and ongrid.
Netmeter लगाकर सोलर डेली कितना यूनिट बना रहा है l देख सकते हैं कि नहीं l चार्ज कंट्रोलर तो बताते रहता है l पर हाइब्रिड इनवर्टर में यूनिट show नहीं करते हैं l यूनिट कैसे देखे बताए l
Sir explain the connection for on grid connection for sub meter also.
Sure
Good diagram,
मेरे यहां uppcl L&T का smart meter लगा हुआ है Bo net meter में change हो जाएगा?
उसका process बता dijiye please
Yes for this you have to approach your local discom office for getting records of smart meter updates to net smart meter .then it will be giving both export and import of power
Nice video sir
What About Hybrid
Agar solar meter nhi lagayege to koe problem hai?net meter se Sirf kam nhi hoga.
Chalega bilkul kaam chalega, abhi complete connection nahi kiya hoga isliye fault dikha raha hoga ya fir ir inverter me koi problem hogi.
मेरे प्रश्न का कोई एक्सपर्ट उत्तर नहीं दे पा रहा, आप से उम्मीद है आप de पायेंगे।
दिन के समय सोलर की बिजली डायरेक्ट कंज्यूम करते हैं कया वो कंज्यूम की हुई बिजली की काउंटिंग इंपोर्ट यूनिट्स में होती है या कहीं भी काउंट नही होती। इंपोर्ट के थ्रू आने वाली बिजली को ग्रीड की बिजली माना जाता है अगर डायरेक्ट कंज्यूम की हुई बिजली इंपोर्ट यूनिट्स में काउंट होती है तो ये मेरे हिसाब से गलत है। सार में मेरा प्रश्न है डे लोड ज्यादा होने पे डायरेक्ट कंज्यूम की हुई बिजली को कौन सा मीटर काउंट करता है।?
एक और प्रश्न, सोलर से आने वाली AC wire को net मीटर के inward साइड पे लगाते हैं या आउटवार्ड साइड, या कोई अलग प्वाइंट होता है, अगर आउट पे लगाते हैं तो दो अलग दिशाओं से आने वाली बिजली का शॉर्ट क्यूं नही होता। कृपया प्रकाश डालें। धन्यवाद।
सर आपके प्रश्न का उत्तर मैं आपको अपने वीडियो में दूँगा, क्योंकि आपका प्रश्न थोड़ा लम्बा समय लेने वाला है।
Thats great. Like your dedication 👍
Distribution valo ko kam karna hoga to hamara solar ka power back marega na
Mere ghar me lga hai kuch din phle. Lekin solar meter nhi lagaya hai. Net meter laga hua hai. Lekin system yani invertor kam nhi kar raha hai. Fault bata raha hai.
Replied on your second comment
Complete connection kar ke chala gya tha but net meter oos time nhi laga tha. To government electricity wale Aa kar lga kar chale gye net meter bad me. Solar wala acdb se 2 wire nikal kar chora hua tha main mcb me lagane ke liye. To wo wire joint hone par bhe invertor work nhi kar raha hai faut Aa rha h display me. Solar wale se bat hua wo aayega 2 din me. Shayad invertor me problem hai
No bro
I'm explained it later don't worry
@@fmkhan84 ho gya bro start ho gya. Wo technician ke galti the jo wire invertor ke out put se nikalta h 1 plastic ke holder ss jisme 3 wire hota h greee, black, red usme wo mistake kiya tha. Usko mai khud sahi kiya. Call krke solar company me.wo wire acdb se joint hota h. Fir acdb se nikal kr 2 wire main mcb ke out me joint kr diya to chalu ho gya. Fault ab nhi h. Running show kr rha. 2000 se 2200 kbhi 2300 watt tak generate kr rha h pannel show kr rha h invertor ke display me. Smart meter lga hua h.
🙏
🙏
Bhai apka whatsp no.kia ha apse hmko Baat Karna ha net metering ke liye
8929612422
Net miter ka video jo diehen sahi se kam karta he na nahi to izzat dub jaega Kal mujhe lagana ek jaga par
Ji jaroor kaam karta hai, befikar ho kar jaiye
Confused
Where?
Too pagal hai or dusaro ko kiya .samghayega
Thanks for the feedback 🙏