220V to 110V | Mga dahilan na hindi galing sa lupa ang isang linya para sa 110V.

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ก.พ. 2025
  • Sa video na ito tinalakay natin ang mga dahilan bakit hindi tayo kukuha ng isang linya para sa 110V.
    #110Volts
    #safetypractice
    #purpose of grounding

ความคิดเห็น • 23

  • @clarencepineda9976
    @clarencepineda9976 หลายเดือนก่อน +2

    So dahil naka bonding yung neutral at ground pwede rin ako kumuha ng linya sa line to ground ?

    • @pinoyelectrical
      @pinoyelectrical  หลายเดือนก่อน

      @@clarencepineda9976 Hindi po pwede na kukuha ng Isang Linya galing sa ground Kasi Ang primary purpose ng GEC naka bonding sa neutral busbar at ground rod ay kun may lightning. Hindi po sa normal electric circuit.

  • @JackylynSag-od
    @JackylynSag-od หลายเดือนก่อน +1

    Sir pwede po ba line to ground gawin 110?

    • @pinoyelectrical
      @pinoyelectrical  หลายเดือนก่อน

      Kun ang ibig mong sabihin ay single phase 2-wire system at Ang system voltage ay 230v/220v , kailangan gumamit Tayo ng transformer. Ang wattage ng transformer ay magdepende din sa load na ilalagay.

  • @dhanielathrop3501
    @dhanielathrop3501 11 หลายเดือนก่อน +1

    So do you suppose to get your newtral ground for 110 volt? Can you explain to me how to add the correct way to run 110 volts. Thank you 🙏

    • @pinoyelectrical
      @pinoyelectrical  11 หลายเดือนก่อน

      I have a video with regards to your question. The title is "220 - 110v Paano kumuha ng 110V."

  • @o0oslayero0o97
    @o0oslayero0o97 ปีที่แล้ว +1

    Sir bakit po may bonding jumper pdin ang neutral at ground na connected sa earth ground?

    • @pinoyelectrical
      @pinoyelectrical  ปีที่แล้ว

      Yes required ang bonding jumper ng PEC. Para merong continuity at sa ganun kun may ground fault magtrip ang breaker.

  • @donatoanastacio5704
    @donatoanastacio5704 ปีที่แล้ว +1

    Meron akong ilang pirasong 110v wall outlet, magagamit ko po ba ito sa paglinya para sa 220v?

    • @pinoyelectrical
      @pinoyelectrical  ปีที่แล้ว

      Pang 110v lang kasi ang rating ng yung wall outlet ay 110V

  • @jaypeepardillo3157
    @jaypeepardillo3157 7 หลายเดือนก่อน +1

    may na check ako 220v sa outlet pero isang linya hindi umabot ng 110v to ground pero ang isa 220v pag line to ground.. ang lakas maka ground..papano ngyare yun kung may naka kabit ng ibang wire?

    • @pinoyelectrical
      @pinoyelectrical  7 หลายเดือนก่อน +1

      Ang system dyan sa inyo ay Single Phase 2-wire system (Line to Neutral).

    • @jaypeepardillo3157
      @jaypeepardillo3157 7 หลายเดือนก่อน

      @@pinoyelectrical may ground kasi boss ...diba dpat ang neutral ay may wire din? para bumalik sa source..kaso yun sa lamesa meron ehh yung equipment nmn walang ground...di kaya kumuha ng supply sa neutral tapos ang neutral naka kabit sa ground lalabs nun parehas may kuryente?

    • @pinoyelectrical
      @pinoyelectrical  7 หลายเดือนก่อน

      @@jaypeepardillo3157 ilang wire ba doon sa service entrance? At song equipment ang nangunguryente?

  • @alfonsoalianza5513
    @alfonsoalianza5513 ปีที่แล้ว +1

    Ang bansang may 110 na appliances ay mayroon ding 120 volts galing sa power transformer

    • @pinoyelectrical
      @pinoyelectrical  ปีที่แล้ว +1

      Good question sir. Sa US at Canada, ang nominal voltage nila kapag single phase transformer (split-phase) ay 120/240v at sa three phase (wye connection) ay 120/208v. So , yes sir mayron.

  • @abrahamalegria8904
    @abrahamalegria8904 8 หลายเดือนก่อน

    Boss ganyan ang ginawa dito sa amin, ok naman ang takbo line to line ang linya namin. Pasok naman yun sa 110volts

    • @pinoyelectrical
      @pinoyelectrical  8 หลายเดือนก่อน

      Hindi pa rin ok yun kasi hindi naman nerecommend ng power provider lalo na sa PEC.

  • @dimz_electric9347
    @dimz_electric9347 2 ปีที่แล้ว +1

    Sa Malaysian Country po kaylangan maglagai ng Earth Group para sa protection

    • @pinoyelectrical
      @pinoyelectrical  2 ปีที่แล้ว +1

      Yes sir sa PEC din sa atin...nirequired na maglagay ng grounding para sa protection.

  • @abrahamalegria8904
    @abrahamalegria8904 8 หลายเดือนก่อน

    Ah hindi recommended pero yun ang ginawa ng iba dito may 110 volts naman.. Line to line pa linya nmin dito.

    • @pinoyelectrical
      @pinoyelectrical  8 หลายเดือนก่อน

      Yun . Hindi recommended pero ginawa parin. Ang mangyari ay ginawang daanan ng current ang lupa , na hindi po dapat ayun sa PEC