when connected to grid but you have pv and batterie connected what will happen if there is a power outage ? will the inverter go through 0 for a few seconds ?
Anything connected to the LOAD port will keep working as if nothing happened (as long as you have enough solar production / battery charge to take on the demand), this inverter will immediately isolate itself from the grid and perform the transfer to ups mode in ms, it's quite impressive. However, keep in mind that the LOAD port is only meant to power type II electronic devices when working off-grid (ups mode). This is because it switches to a floating neutral configuration, which has no earth reference. In this configuration, RCDs won't trip and some devices won't work. If you want it to power type I electronic devices safely and want your RCDs to work when in ups mode, you need to add an external contactor connected to the inverter's ATS port, to perform a neutral-earth bond (only when off-grid). Sunsynk made a couple of videos about it, check them out.
Salutare! Back-up boxul la invertoarele deye monifazate (3-6kw) este integrat sau se achiziționează separat? Mă interesează dacă funcționează fara rețea doar de la panouri fara baterie cum sunt invertoarele sungrow si sofar....
No, it needs to be plugged exactly in this way. It may look as a standard network cable but the ends are specific to the ports of the inverter and battery.
when connected to grid but you have pv and batterie connected what will happen if there is a power outage ? will the inverter go through 0 for a few seconds ?
Anything connected to the LOAD port will keep working as if nothing happened (as long as you have enough solar production / battery charge to take on the demand), this inverter will immediately isolate itself from the grid and perform the transfer to ups mode in ms, it's quite impressive.
However, keep in mind that the LOAD port is only meant to power type II electronic devices when working off-grid (ups mode).
This is because it switches to a floating neutral configuration, which has no earth reference.
In this configuration, RCDs won't trip and some devices won't work.
If you want it to power type I electronic devices safely and want your RCDs to work when in ups mode, you need to add an external contactor connected to the inverter's ATS port, to perform a neutral-earth bond (only when off-grid).
Sunsynk made a couple of videos about it, check them out.
@@Goreuncle What is a type 2 electronic device never heard of such a classification
@@Goreuncle
Hello. How can resolve my problem? When svich off grid ,i have 115 Volt between F and PE and 115 between N AND PE.
Salutare! Back-up boxul la invertoarele deye monifazate (3-6kw) este integrat sau se achiziționează separat? Mă interesează dacă funcționează fara rețea doar de la panouri fara baterie cum sunt invertoarele sungrow si sofar....
Hola, me gustaría saber que app tiene el inversor para conectarlo al móvil y como quitar la tapa para.conectar la antena wifo, gracias
why battery data cable Bat_Com and Inv_Com .. are this not allowed to be reverse ? or this cable same with networking cable ?
No, it needs to be plugged exactly in this way. It may look as a standard network cable but the ends are specific to the ports of the inverter and battery.
Excellent
Hello i order hybrid inverter with battery. I want sale extra electricity to grid. How wiring will be happen. Can you please help me
what is different between sg05 and sg03 or sg04?
I know that 03 have passive cooling ( no fans), and 05 is with fans.
This inverter with battery very good
Screwing and unscrewing using an electric screwdriver instead of manual one is some kind of perversion...
Браво ,без да продаващ ток само за лично ползване ,настройките можели видео ,имам от същия deye 5kw ,скоро ще си вземам v-tag батерия
Здравейте! Във видеото са показани настройките нужни за стартиране на инвертора с използване на енергията без продаване.