Solid video. Just a few new points. Minimum 2 samples per RBW. This scope has a fixed 751 sample span. Thus, 9000/2 * 751 gives a max span of 3.38MHz. So you can't actually sweep from 1MHz to 30MHz all at once. Also, there is a minimum required sample time of 200s / MHz for the EMI filter. I think sample time is in the sweep menu?
Thank you for that explantion. Siglent SA works almost exactly the same. Final comment: focus.
Thank you for your great videos and great explanation.
Solid video. Just a few new points. Minimum 2 samples per RBW. This scope has a fixed 751 sample span. Thus, 9000/2 * 751 gives a max span of 3.38MHz. So you can't actually sweep from 1MHz to 30MHz all at once. Also, there is a minimum required sample time of 200s / MHz for the EMI filter. I think sample time is in the sweep menu?
External input protection device for SA is a must especially for conducted EMI measurement.
what would happen otherwise?
oh man, more stuff I don't know how to do.