What is Sample Rate and What to Be Cautious Of

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ม.ค. 2025

ความคิดเห็น • 72

  • @KeysightLabs
    @KeysightLabs  5 ปีที่แล้ว +9

    Check out the free SI whitepaper and ebook download here: bit.ly/eBOOK_SigIntegrity
    Thanks for watching! Let us know if you have any questions or comments.

    • @FixItStupid
      @FixItStupid 5 ปีที่แล้ว +1

      Good Job I wonder if the technicians really understand .... I've used both, and I prefer analog ....

    • @reedreamer9518
      @reedreamer9518 3 ปีที่แล้ว +1

      She's well trained at reading a script, but why doesn't Keysight use men for PR rolls like this? Obviously Keysight discriminates unfairly against men. For me this is insulting, and while shopping for a new oscilloscope I will be looking at other company's products.

  • @drawingboard82
    @drawingboard82 5 ปีที่แล้ว +18

    These videos are the best advertising you could make. love it.

  • @barrykery1175
    @barrykery1175 3 ปีที่แล้ว +3

    Great video. I learned a lot about sampling rates. I already understood how important having a high sample counts but knew nothing about the interleaving. That's was very interesting and super easy to understand due to how you presented it.
    Thanks, well done,
    Barry

  • @llamasarus1
    @llamasarus1 3 ปีที่แล้ว +2

    Thank you! I was reading "Computer Science Illuminated" and it brushed through this topic without sufficiently explaining it but you explained it in a way I understand.

  • @SoJesusChristMusic
    @SoJesusChristMusic 3 ปีที่แล้ว +3

    I LOVE IT! Great information hands down!

  • @davoodseify3624
    @davoodseify3624 4 ปีที่แล้ว +1

    don't have enough money to buy Keysight oscilloscope but always watch your informative and fantastic video to learn something.So thank you :)

  • @MaouXY
    @MaouXY 4 ปีที่แล้ว +3

    So clear! I love those videos! 😍

  • @saniljhaveri
    @saniljhaveri 5 ปีที่แล้ว +2

    Fundamental RF concepts simplified & Well Presented !

  • @SurfinScientist
    @SurfinScientist 5 ปีที่แล้ว +6

    So, what is the brand of the oscilloscope that doesn't synchronize its ADCs properly in the shown example?

    • @soderdaen
      @soderdaen 5 ปีที่แล้ว +3

      From the screen it looks like a Tektronix

  • @arduinomaquinas
    @arduinomaquinas ปีที่แล้ว

    Awesome 🇧🇷😉👏👏👏👏 very cool video, subscribed, thank you girl

  • @Mr2Xri
    @Mr2Xri 3 ปีที่แล้ว

    Hello, at 7:59 is there a mistake?... maybe want to say ("above" the fundamental 2.5GHz) instead of "below"?

  • @HyperF1
    @HyperF1 5 ปีที่แล้ว +4

    A clear lecture and hypnotic lip movements, such a speech therapy!

  • @SalamanderDancer
    @SalamanderDancer 4 หลายเดือนก่อน

    If you had a choice of using 1 ADC at 1x sample rate versus doubling your sample rate by interleaving 2 ADCs, which measurement would be better? Is there a crossover point where the benefit of 2x the sample rate is gone when the time skew between the ADCs differs by some amount relative to the sample rate?

  • @vishva8kumara
    @vishva8kumara 4 ปีที่แล้ว +2

    3:06 There is a fault in these diagrams. A wave does not go backwards.

  • @444guns
    @444guns 3 ปีที่แล้ว

    @1:15 - wait, what exactly is that "sampler" before the ADC ? I thought the ADC is the one responsible for sampling, the actual analog to digital conversion being the sampling process.

    • @thomasmaughan4798
      @thomasmaughan4798 2 ปีที่แล้ว +1

      That would be the sample-hold device. It follows the input, keeping a tiny capacitor at the voltage it sees. When "hold" happens, the tiny capacitor stops following the input voltage and simply holds whatever voltage it has so the ADC can measure it. Most ADC designs cannot correctly encode a signal that changes voltage during the measurement process.

  • @ranjanpal7217
    @ranjanpal7217 4 ปีที่แล้ว +1

    Amazing Explanation...Just a query..Can I say for using ADC on Raspberry Pi, (Sampling rate of ADC from manual)>(4*Highest Frequency in my measured signal)

  • @dixsusu
    @dixsusu 5 ปีที่แล้ว +2

    As always great presentation and explanation !

  • @JismalJamal
    @JismalJamal 5 ปีที่แล้ว +1

    Ok keysight likes geeking out.Love these well explained vedio. Especially what the RF

  • @lowearthorbit-delio
    @lowearthorbit-delio ปีที่แล้ว

    nice explanation. thanks

  • @markg735
    @markg735 3 ปีที่แล้ว +1

    Really a great video. I never thought about those insanely high Sa/S scopes and how they achieved that. Sometimes we have to live with a low end scope from "another vendor." LOL

  • @techsinc
    @techsinc 5 ปีที่แล้ว

    You need to be clear on what you mean by resolution. You yourself stated the Nyquist theorem. Higher sampling rate will increase the resolution of the wave form up to the point of Nyquist frequency limit given a sampling rate. Your time resolution is NOT increased (assuming you are already at high enough sampling rate). Time resolution is determined solely by the bandwidth limit of the scope.

  • @soroushmoallemi774
    @soroushmoallemi774 5 ปีที่แล้ว +2

    Excellent explanation. Thank you so much!

  • @ray5d
    @ray5d 5 ปีที่แล้ว +11

    3:00 It looks like some samples just time traveled😂

    • @snnwstt
      @snnwstt 5 ปีที่แล้ว

      Exact ... unless it is a sample exposed as x-y instead of y-t.

    • @Mystninja
      @Mystninja 4 ปีที่แล้ว

      I'm now dumber and not sure what I Just watched. I think I'm missing some info. So I'll stick to 48

    • @adrianoinfante6365
      @adrianoinfante6365 วันที่ผ่านมา

      LOOOOL

  • @jaakjaak0427
    @jaakjaak0427 ปีที่แล้ว

    Discussing interleave distortion, with no mention of calibration and lab environment impact to instrument performance is leaving a gaping hole in the topic. It's easy to make a vendor's instrument crap the bed by forcing a self cal in one environment then moving it to another to do the measurement.
    Also some vendors suppress artifacts from their digitizers knowing they occur.
    It would also be nice to drop a note about waveform update rate and if it's continuous or in bursts, especially when you bring up "glitch"
    Otherwise, great vid.

  • @qzorn4440
    @qzorn4440 2 ปีที่แล้ว

    also there is cost per glitch to capture small details. For high end R&D more is better "007" leading to very high end equipment or use lesser test equipment for hobby projects. 😎 thanks.
    looks like the: Keysight MSOS804A - Mixed Signal Oscilloscope (8 GHz / 4 Analog Channels / 16 Digital Channels) at TE Equipment is $101,466.00 on 11/12/2022 🥰

  • @mousamupadhyaya8053
    @mousamupadhyaya8053 5 ปีที่แล้ว +1

    What a coincidence, i was reading about Nyquist sampling rate on my book :)

  • @FSXgta
    @FSXgta 5 ปีที่แล้ว +2

    This is a good video don't get me wrong, but I don't understand the need to put constant music in the background. If i wanted that I could do it myself...

    • @KeysightLabs
      @KeysightLabs  5 ปีที่แล้ว +1

      Thanks for the feedback!

  • @battlecoder
    @battlecoder 5 ปีที่แล้ว +7

    **"Another vendor" wants to know your location**

  • @sunuk1915
    @sunuk1915 4 ปีที่แล้ว

    How much price of this model oscilloscope?

  • @isurunuwan2575
    @isurunuwan2575 5 ปีที่แล้ว

    Finally I got it. Thank you very much dear

  • @artursmihelsons415
    @artursmihelsons415 5 ปีที่แล้ว +2

    Thank's for great topic.. :)

  • @glasslinger
    @glasslinger 3 ปีที่แล้ว

    Yea, I will. When I get rich enough to have a scope where it matters!

  • @annoorkhan4219
    @annoorkhan4219 ปีที่แล้ว

    Nice , thanks.

  • @TheDefpom
    @TheDefpom 5 ปีที่แล้ว

    Nice and clear explanation.

  • @clems6989
    @clems6989 2 ปีที่แล้ว

    Hence, why we keep an analog scope in the shop also...

  • @Moocowmadcactus
    @Moocowmadcactus 3 ปีที่แล้ว

    To summit up you’re just saying that my song is forever unfixable🥺 thanks

  • @JimmyMakingitwork
    @JimmyMakingitwork 4 ปีที่แล้ว +4

    I learn more from an attractive nerd than from anyone else. :) lol. Thank you!

  • @vladimirrodionov5391
    @vladimirrodionov5391 5 ปีที่แล้ว +2

    Looks like she is wearing a Black Sun pendant.

  • @no5x937
    @no5x937 5 ปีที่แล้ว

    Your website form rejects my legitimate business email address and personal email address. Fix it!

    • @KeysightLabs
      @KeysightLabs  5 ปีที่แล้ว

      Weird! We haven't seen any trouble with it, can you try a different browser or try clearing your cache? What error message are you seeing?

  • @ReevansElectro
    @ReevansElectro 5 ปีที่แล้ว

    This makes me want to run out and get a new scope!

    • @jonahansen
      @jonahansen 5 ปีที่แล้ว +2

      I know, right? Just gotta remortgage the house first for the money...

  • @shamvibhute136
    @shamvibhute136 3 ปีที่แล้ว

    impressive.

  • @samuelschwager
    @samuelschwager 5 ปีที่แล้ว +1

    Let's go even further: Why even sample at all? Just make a guess :P

  • @CABohol
    @CABohol 5 ปีที่แล้ว

    Nice

  • @andyheater
    @andyheater 5 ปีที่แล้ว +1

    5th comment

  • @cybertiesje
    @cybertiesje 4 ปีที่แล้ว +1

    It's a tad ironic I think that a video about loss of signal is so overexposed.

  • @sunuk1915
    @sunuk1915 4 ปีที่แล้ว

    Just introduce ABCD

  • @mgfails9274
    @mgfails9274 5 ปีที่แล้ว

    3rd

  • @reedreamer9518
    @reedreamer9518 3 ปีที่แล้ว +2

    Notice She speaks one sentence at a time, with edit breaks in between, because she's reading a script. Anyone can read a script, but why doesn't Keysight use men for PR rolls like this? Obviously Keysight discriminates unfairly against men. For me this is insulting, and while shopping for a new oscilloscope I will be looking at other company's products instead. If you see male sex discrimination like this, in your university or corporation, speak up and take action!

  • @KommynusT
    @KommynusT 5 ปีที่แล้ว +2

    Girl is too happy in movie. Annoying. little suffer on her face, it will make video professional look

    • @ketas
      @ketas 3 ปีที่แล้ว +1

      maybe she likes her job

  • @Mystninja
    @Mystninja 4 ปีที่แล้ว

    Wtf R U on about.
    It's not rocket science. Just double for -/+ and ad 400 for film.

    • @KeysightLabs
      @KeysightLabs  4 ปีที่แล้ว

      😅

    • @Mystninja
      @Mystninja 4 ปีที่แล้ว

      I do apologize about my not understand. Mix sounds with video is one of the hardest thing. To sync up. And depending an what the video is for. I've learn that you can't sync sound and video at different rates. It's hard but it's easy at the same time. Less is more and more is less.
      Ever wanted to know why sound and video goes out of sync sometimes after playing a long shoot. Well it's the sound recording and video formats are at different rates. Took me 30 odd years to work that out. And using cheap gear.

  • @ryanmigliori9142
    @ryanmigliori9142 5 ปีที่แล้ว +1

    Wear glasses next time.!