Kabhi try nhi kia lekin jahan tak mera khyal hy VFD me acceleration / Deceleration or minimum or maximum frequency ka option bhi hota hy. Aap minimum (48Hz) or maximum (52Hz) ki settings set kr k bhi safety ensure kr sktay hain as per my knowledge.
U forgot to mentioned that we have to disable vfd output phase failure protection. Command PB.01 and then select 0 to disable With this setting invt will never trip on single phase system
سلام برادر ھم تو اسے گھریلو طور پر استعمال کر رہے ہیں ۔کوئ مسلہ پیدا نہیں کرتا ۔ لیکن آپ یہ ویڈیو ضرور اپلوڈ کریں کہ الیکٹرونک اشیاء اس پر کس طرح چلائی جاتی ہیں
assalamo alaikom bahi. ap ne kaha k capacitor wali equipments nahi chala sakty vfd pe. jab k single phase submersible pump to chal rahy hain vfd pe. us k ly kia koi special setting krni hoti hai ya yeh jo ap ne p.04 pe jo voltage change key hain yehi kafi hain.
Sir VFD to three phase out nikal rhi hay ager hum is pr single phase load run krtay hayn to kya ye 1 phase use na honay ki waja say trip nae hogi........?????? Plz is baray me rehnmai frmayn. Singlae phase water pump ru krwana hay me nay.
plz sir reply kren zroor Sir kya hum dono cheezain chala sakte hain ek hi setting pe agar motor chalain to ghar ka load off karen aur ghar ka load chalain to motor off kren dono main breaker laga ker
Assalam-o-Alaikum jnb meray pas 7.5 kw sbmrcible or summer pump hy 20 sollar pannel hain aur 7.5/11 kw vfd hy kia main us pr toka machine chla skta hon p
Bhaiee ki maloomat main agar ezafa karun tu 1.acceleration time dead karen gy 2.Seting stop mood ko coast to stop par karen gy 2. Digital/analog timer lgain gy au magnatic contactor lagain gy ya pher digital voltage control relay single phase istemal karen gy jis main ham seconconds k hisab sy on hony ka time dy sakty hain DUAON MAIN YAAD
Agr single phase 220Vac pr three phase motor chlani ho tu kya hme koi input voltage ki setting krni pre gi? Or 220 Vac kis terminals pr apply krne? Kindly guide.
Asslam o alaikum R ye Jo vfd inverter ajkl market main aey hen Jo direct solar panels sy single phase load chalaty hen unky bary main btaen unki b frequency km zyada Hoti rehti hy q k without bettery work krty hen direct sunlight sy is bary main maloomat krni hy
Payaray bhai ap kya ye bata skty hain ki signal face 3kw ki submersible motor vfd 11 kw vali pr chala skty hain 3face motor to esy chal jati lakin siglngal face chly gi pls tell me
Knowledgeable video. Sir.
Pakistan or Hindustan vi zindabad
جزاک اللہ و احسن الجزا اپ کی ویڈیوز معلومات سے بھرپور ہوتی ہیں اور بہت سارے لوگ بہت بڑے بڑے نقصانات سے بچ جاتے ہیں
ماشاءاللہ ماشاءاللہ بہت زبردست اپنی ٹکنالوجی ہم نے بتائی ہے پورے لوگ اس پر فائدہ اٹھایا اور اللہ تعالی آپ کو مزید برکت عطا فرمائے
سر استری چل سکتی ہے اس پہ vfd خراب تو نہیں ہوگی
Nahi
میرے پاس وی ایف ڈی 37 تا 45 کی ھے ٹربائن پر موثر 40 کی چل رہی ھے اس پر بھی 220چل۔جائے گا رہنمائی کرے بھائی مھربانی ھوگی سید اخلاق حسین شاہ
Thank you so much, yahi sawal mere zehn me ta 1 electrician se pucha b ta lkn us ne mujhy jawab nhi dia... Ap ne mera sawal ka jawab de diaa😘
زبردست جناب عالی لالا جی نورپو تھل
مدثر بھائی اسلام علیکم آپ کو دل کی گھرائیوں سے عید مبارک ہو ۔
Waalikumassalam bhi apko bhe eid mubarak
Bhai Altivar 21 30 hp pe b video bnaye terminal define kre
Nice information. Thanks. KHB
بہت خوب ویڈیو ہے
شکریہ بھائی۔
مدثر بھائی اسلام علیکم ورحمتہ اللہ وبرکاتہ
میری طرف سے آپ کو بہت بہت عید مبارک ہو
waalikumassalam apko bhe eid mubarak
Kamal ke video ha
V nice from Dubai
Very good Bhai g a2z
Aslamu Alaikum sir mudasar meri tarf se apko bohat bohat eid mubara ho
Thinx sirg boht achaa
Good mudasir bhai
Zaberdast bhai very nice info
Aslamualikum bhai app bohat achi vedio bna rahe hain
Thank u bhai ...mne chla liya❤
Outstanding 👍👍
❤ good sir Allah aap ko kush rkhy aur bhi jaan myny aap ki dawt krni Hy ❤❤❤❤❤❤❤
JazakAllah khush rahen peyary bhi
Very Good
Nice 👍
Thanks sir
JazakAllah Thanks
Thank you so much
جزاكَ اللّٰه
Very very very nice sir
Kabhi try nhi kia lekin jahan tak mera khyal hy VFD me acceleration / Deceleration or minimum or maximum frequency ka option bhi hota hy. Aap minimum (48Hz) or maximum (52Hz) ki settings set kr k bhi safety ensure kr sktay hain as per my knowledge.
Sir confirm kry if its true then its batter than so called pur sinwaves day time inverter, alway fluctuate voltage due to weather ☁️.
Ap ki setting se ap ni chla pao ge
Good job
Good
Very informative video.👌👌👌
Very nice video sir thank you
Very nice
U forgot to mentioned that we have to disable vfd output phase failure protection. Command PB.01 and then select 0 to disable
With this setting invt will never trip on single phase system
Good agree
Really amazing you get agree on comments!!!!!!!!?????
@@a2zsolar drictly down frequncy 30hz and run all single phase applinces (agree)
@@a2zsolar agar nai chala saktay tou video keon banai
@@a2zsolar why ur team not response me on you tube
Excellent information
سلام برادر
ھم تو اسے گھریلو طور پر استعمال کر رہے ہیں ۔کوئ مسلہ پیدا نہیں کرتا ۔ لیکن آپ یہ ویڈیو ضرور اپلوڈ کریں کہ الیکٹرونک اشیاء اس پر کس طرح چلائی جاتی ہیں
سر آپ استری چلاتے ہو اس پر
APNA number send krna Bhai jaan
Buhut informative but hum chota welding plant challa sakte heen?
Assalam o Alaikum brother, if filters are used after setting 220v on vfd then can we run all house hold appliances safely please
gud job
Acha bhi vfd ky sat solar panel kis trha attach krny ha
Series / pararal??
Auslam u Alikum
Kya old non inverter ac 1ton chala sukty han . Aor ampear kum ho jay gaye
assalamo alaikom bahi. ap ne kaha k capacitor wali equipments nahi chala sakty vfd pe. jab k single phase submersible pump to chal rahy hain vfd pe. us k ly kia koi special setting krni hoti hai ya yeh jo ap ne p.04 pe jo voltage change key hain yehi kafi hain.
Bye 8 solar par kise on kardenge 8 solar par poff ate ha
Mudassar bhai aapane TH-cam per jo Jo video Banaye vfd ke muthalaq Ghar Ki capacitor chijen na chalayen Hamen bahut yah video acchi lagi
Singal phas motar as phar chal sakte hai
Aslaam o Alaikum sir.
Sir g kia 3phase motor aur single phase load ek sath chala saktey hn please inform as soon as possible
Ajj kl market mi filter naam ki koi cheez hi jo shop waly khty hi k vfd ki saat LGA lo, ur bfikr sary gar ka loud chalo. Plz explain the filter
Price
Welding chal sakta he plz.. btaa den shukriya
Kia Bahi single.phase pa ger ka nazm chla skta ha as inv paa koi msla tu nie o ga or natuel wire kdr sa la ga
Sir is pr singl face seeling fan and singl face capacitor wali moter hi chla k dikha do
kia VFD say Desi UPS chala saktay hay. VFD Desi UPS k leyee wapda ka kam karay ga ? confirm please
Sir is sating p water pump motar r ghrelu 220v dono ik hi time chal skti hin kia.???
Bohat achha. Or hum ye janinena chahty hen k baki jo Rb waly etc kis connection k lia hen??
ASSALAMUALAIKUM,
Bhai hum 50 Hz fix program karke kya 220 par nahi chalaa sakte.
Frequency fix kar sakte hai.
Starting torque
Sir jub dhoop kum ho ge tub band ho jay ga .
Wesy ye ho sagta hy
اللہ پاک آپ کو مزید کامیابی کرے
Agr acceleration aur deceleration time 0 kr dy to direct chla skty hn
Bhi sky power inverter k bi same display aur setting hai?
Assalamulaikum sir asa ghr ki bijli is pe krny se wapda meter pr load ka frak pray ga ya ni
Bro me AP KO sari chizle chala k donga 220 v Jo b ciz ho video bhot achi ti
Heating element chalega is pr?
AoA bhai jan Kaisy ho 3 phase vfd per single phase 220 volt wapda pesco sy chala skaty hy kia
Sir 5 hp ki single phase motor hai. Vfd per chalana hai. Kitnai solar required hon gai. Kia yeh recommend hai ...
Sir yhan se 1500w ka inverter lgaa kr agy CPU LCD etc chla skte hn
Sir VFD to three phase out nikal rhi hay ager hum is pr single phase load run krtay hayn to kya ye 1 phase use na honay ki waja say trip nae hogi........?????? Plz is baray me rehnmai frmayn. Singlae phase water pump ru krwana hay me nay.
Bhai signal face ro plant Soler pe kase chale ga
plz sir reply kren zroor Sir kya hum dono cheezain chala sakte hain ek hi setting pe agar motor chalain to ghar ka load off karen aur ghar ka load chalain to motor off kren dono main breaker laga ker
Single phase wali 3hp ki motor cha lana ka liya kon sa vdf or kita ni plates 585 no utility use only solar works
Hamary elaqy mein madarsa hy Jamia Ashraf ul Uloom 2 months sy 60 celling fan 3 fridge kuch led lights chalty hy Fronis company ka vfd hy
Ya dril mechanic to direct dollar pr b chal jati ha barother q k Ya R macher ha
Assalam-o-Alaikum jnb meray pas 7.5 kw sbmrcible or summer pump hy 20 sollar pannel hain aur 7.5/11 kw vfd hy kia main us pr toka machine chla skta hon p
Sir uspy refrigerator chal sakta he???
Please reply
sir ap seting bta inviter ki vfd jis compny ka bhi ho ham us ki seting khud kr skty
Sir is main sirct wali chez chala skty jaisy LED tv mobile charge lga skty hy
Is vfd main input single phase diya hai ya three phase diya hai
Bahi jan 10hp ke 3face motor ko delta mn connect krn ya star mn
Bhai es k sath solar ktny aur ktni wad waly lgty hn
Is k saath solar plate kitni lagani chahye bhai jan
Inverter lagane k baad vfd use krskte hain Air conditioner ya Pani kheechne aur lifting pump ko ???? For permanent use ???
Bhai 11/ 15 ki vfd pe freezer ya dc inverter ac chala saktay hain kia.
Mashallah bouth sukriya bahi
Single phase capacitor motor Run kar sakte hain ya nahin sir 0.75kw/1 hp
Bhaiee ki maloomat main agar ezafa karun tu
1.acceleration time dead karen gy
2.Seting stop mood ko coast to stop par karen gy
2. Digital/analog timer lgain gy au magnatic contactor lagain gy ya pher digital voltage control relay single phase istemal karen gy jis main ham seconconds k hisab sy on hony ka time dy sakty hain
DUAON MAIN YAAD
Is py toka masheen chla sakty han myry pas 585wt k 8 panel Han ar 7.11 ka invt ha
Agr single phase 220Vac pr three phase motor chlani ho tu kya hme koi input voltage ki setting krni pre gi? Or 220 Vac kis terminals pr apply krne? Kindly guide.
What if we install filter for it
Vfd 1 hp ki motor ka torque kam karne keleye lagasakte hn single phase vfd single phase ki motor
Use voltage controller its cut in and cut off at rated voltage
Asslam o alaikum
R ye Jo vfd inverter ajkl market main aey hen Jo direct solar panels sy single phase load chalaty hen unky bary main btaen unki b frequency km zyada Hoti rehti hy q k without bettery work krty hen direct sunlight sy is bary main maloomat krni hy
Aggy voltage protector lgaoo jo mirzii chlaoo bgar kssi dr k😊
G ya 3 solar sy on hota hain ??
ماشاءاللہ۔ بہترین معلومات
بھائی اسلام علیکم میرا سوال ہے 220 کی صورت میں اس vfd کو پیلٹر لگانا ضروری ہے یا نہیں
ye serf resistive load chal raha hay pory ghar ka load dain lch.lap top computer .resistive load soalr per barayraast chal sakta hay
R or T pr kya supply di ha? 220v or 380v?
Vfd my ja ky setting krny sy asa nhi ho sakta ky ham 1 phase use kr ly
Welding plant chal jae ga
Ostad ya ups singall fys my ketna lod chla sakta ha
1 phas ly kr or zmeen sy erth ly kr ni chla skty kya
Sir 3 phase moter ko 220 connection Kar ke run karwa sakty hain
Yes
Payaray bhai ap kya ye bata skty hain ki signal face 3kw ki submersible motor vfd 11 kw vali pr chala skty hain 3face motor to esy chal jati lakin siglngal face chly gi pls tell me
Or kya ham is ko frequency ko 50 py confirm kr skty hen ?
Sir iss py ham Ac chala sakty hain
AOA bhai mery pass k electric ka singnal phas meter hy kia ma 3phas 3hp ki moter kysy cgala sakta hun rehnumai farmain jazak ALLAH khyr