How to Zone a Forced-Air Furnace and Air Conditioner | Ask This Old House

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ก.พ. 2025

ความคิดเห็น • 92

  • @jeromemorgan9992
    @jeromemorgan9992 4 ปีที่แล้ว +9

    The look on that guys face is like he is doing a hostage video

  • @RobertBrown-fp9ht
    @RobertBrown-fp9ht 4 ปีที่แล้ว

    Thanks Richard. I always learn something when I watch your videos!

  • @adwaitjog
    @adwaitjog 4 ปีที่แล้ว +3

    You installed the bypass damper, however, did not install a discharge air temperature sensor (DATS).

  • @antoniocortez1326
    @antoniocortez1326 4 ปีที่แล้ว +3

    Help me out.. what's the tool called that he use to cut out a perfect circle on the return box?

    • @knockitofff
      @knockitofff 4 ปีที่แล้ว

      Malco HC1 i think

  • @coryzahradnicek261
    @coryzahradnicek261 ปีที่แล้ว

    This is interesting i have a split level house . The upstairs is above the garage. Duct works runs in the garage finish ceiling for the upstairs. Always freezing cold in winter. I Had hvac company looking into the problem. They said my only real option was adding electric baseboard heating for the upstairs.

  • @Mikem-mq2hh
    @Mikem-mq2hh 11 หลายเดือนก่อน

    How big (sqft) is the house?

  • @sjcea0512
    @sjcea0512 5 ปีที่แล้ว +1

    Where do we buy this ???

    • @davidvennette2200
      @davidvennette2200 4 ปีที่แล้ว

      That is what i would like to know. I live in a one story home and the front of my house is always cooler then the back half. id love to zone my bed and bath room off from the kitchen, office, and livingroom.

  • @scottye1925
    @scottye1925 2 หลายเดือนก่อน +1

    Cool dude

  • @professorquack
    @professorquack 3 ปีที่แล้ว

    good job rich

  • @boedillard8807
    @boedillard8807 2 ปีที่แล้ว +2

    Would love it if he slowly explained the how a room is configured with the vent and return.

  • @zeframcochrane5271
    @zeframcochrane5271 3 ปีที่แล้ว +1

    Oil Furnace

  • @theodore1228
    @theodore1228 7 ปีที่แล้ว +1

    How about a link to this company's system so that we can look for installers and providers in our area?

  • @mlefe09
    @mlefe09 4 ปีที่แล้ว

    Excellent info!

  • @ashroy108
    @ashroy108 5 ปีที่แล้ว +2

    I need to do exactly the same thing for my house for 2 levels of controls - one for upper floors and another for basement. Can anyone help?

    • @BillyN31
      @BillyN31 5 ปีที่แล้ว

      Ashoke Roy what state?

    • @withchza
      @withchza 4 ปีที่แล้ว +2

      A cheaper thing to do would be to open the dampers manually in the rooms on the upper floor and close the dampers in the basement rooms during the summer. Do the reverse in the winter. This keeps the cooIer air upstairs and cool air sinks so the air will move down to the basement. Usually the basement stays cool during the summer anyway. I'd also buy fans (or ceiling fans if you can afford it) for the summer, and space heaters in the winter. Just run them when someone is in that particular room. You can get space heaters with thermostats for $40, floor fans are cheaper. Buying about 4 of each is around $250. Using them isn't going to raise your electric cost that much. In fact, you may be able to turn the thermostat down in the winter and up in the summer to offset costs. A new system will cost thousands of dollars, which you won't recoup in savings until probably 20 years, at best.

  • @JuanCarlos-bk3nz
    @JuanCarlos-bk3nz 6 ปีที่แล้ว

    I have a central heat and a/c with 3 zones, one of the dampers has power but 0 volts. I would like to know where is the problem, is damper or the electrical box that control the whole system. I changed all 3 thermostat and did not fixed the problem. Thank you for your help.

    • @MarkMark-kq6mc
      @MarkMark-kq6mc 5 ปีที่แล้ว

      Juan Carlos -sounds like you need to call a qualified hvac contractor

  • @babur729
    @babur729 7 ปีที่แล้ว +1

    what a nice video!

  • @mrp8192
    @mrp8192 6 ปีที่แล้ว

    I really this video.
    I want to know more about air distribution and duck system.
    I have RMO license.
    Do you know any training i could take ?
    I live in Brooklyn,Ny.

    • @eth6706
      @eth6706 5 ปีที่แล้ว +2

      You can find out more about ducks at your local pond.

  • @budfox
    @budfox 3 ปีที่แล้ว

    How much should it cost to install the Zone Dampening system, on 2 story Townhome when building one. The builder is asking for $7.7k and I don't see it costing that much in addition to what you already showed. 3 floors 3 thermostat, 3 zones. shouldn't cost 7.7k

    • @jfabritz
      @jfabritz 3 ปีที่แล้ว

      I assume that includes the cost of the furnace and A/C unit since that seems fair. Not sure how they designed it, but if there is extra ductwork plus the cost of the equipment, it will be a couple thousand dollars for sure.

    • @abacab87
      @abacab87 2 ปีที่แล้ว

      shop around, you'd be surprised what the difference in cost is. The bigger guys have to charge a lot, and if you get someone that they hired, he may not be good. A small business owner/installer guy will give you a better job at less cost.

  • @MoonLiteNite
    @MoonLiteNite 7 ปีที่แล้ว

    having some issues with my unit, no heat, cool or fan.
    Noticed one of my ducts fell down from the rack and i was ignoring it.
    Noticed it had a "handle" just sitting there. Turns out it is that bypass thing valve.... that would explain why my airflow as sucked for 2 years....
    Still have my main issue but i thought that was funning :D

  • @vinaysunku3333
    @vinaysunku3333 6 ปีที่แล้ว +2

    Hi Richard Can the zone air conditioning ( heating or cooling)system be added to any heating or cooling unit or does it have to be a special type ?. I was consulting a local HVAC company representative to have zoning done for my house and was told that the zoning can not done on a single stage unit and it has to be variable stage or two stage unit. This amounts to changing my existing unit that is still in very good condition and probably has another 10 years of life. Also I was told that it is illegal to place a bypass duct in California because of health concerns. I am not sure if that is true or if there are any real health concerns and if so what kind of health concerns?. Appreciate your expert advice.

  • @rodgraff1782
    @rodgraff1782 ปีที่แล้ว +2

    That’s right bypass hot air right back into the intake of the furnace. This will cause the furnace to cycle on the limit, or lock out completely. Every zoning system needs a discharge air temperature controller that will cycle the furnace off before the limit trips. Most of these zoning systems make the equipment cycle on and off excessively. This is like trying to make a variable air volume system, work with constant volume heating and cooling equipment. You can get by with a few dampers, if the ductwork is a little oversize, but 23? I didn’t know the zone control boards could handle that many, unless they used DDC type communication.

    • @Egleu1
      @Egleu1 ปีที่แล้ว

      There's two zones. Each damper is daisy chained to the next one in that zone. You have the same bypass with a whole home humidifier and that works just fine.

  • @charlesbryant8947
    @charlesbryant8947 7 ปีที่แล้ว +7

    Should do a vid on the call back when it freezes up or cuts out on high limit should have used an ECM variable speed

    • @BillyN31
      @BillyN31 5 ปีที่แล้ว

      Charles Bryant that’s what the bypass damper does. It mitigates that

    • @victory21222
      @victory21222 4 ปีที่แล้ว +1

      ​@@BillyN31 No Charles is correct. The air coming out of the air handler has been cooled about 20 degrees from what it returned at so lets say the 2nd floor stat is set at 70 degrees. and the room is 73 degrees. The thermostat on the first floor is most likely satisfied thus closing the first floor dampers. That means air returning at 73 degrees from the second floor is being cooled to 53 degrees after it passes through the evaporator and heads out the plenum. So as soon as the air heads out of the plenum it will get redirected through the bypass because the first floor t-stat is satisfied. That means the air that has just been cooled 20 degrees is being sent right back a second time through the evaporator coil and cooling it an additional 20 degrees. I realize the air is going to be mixed with some return air from the second floor but lets say it is lowered 10 degrees instead of 20 degrees. That would calculate to 43 degree air entering the evaporator. The refrigerant temperature would be about 10 degrees lower which would make for a 33 degree coil. If it ran very long like that it would start to ice up. If the system was undersized like mine it would definitely start icing up. Not tryin to be dis agreeable but it could develop problems and lead to early compressor failure from liquid slugging back to the compressor due to low superheat.

    • @BillyN31
      @BillyN31 4 ปีที่แล้ว

      victory21222 ok. I love your logical thinking! Thanks for being one of the few comments that is actually intelligent!

  • @ColinBeirneSYR
    @ColinBeirneSYR 8 ปีที่แล้ว

    so when I bring wire in the wires on the smoke detector will be like pigtails.? @ThisOldHouse

  • @phillemmert7909
    @phillemmert7909 8 ปีที่แล้ว

    Good vid

  • @traciescampbell9166
    @traciescampbell9166 4 ปีที่แล้ว

    where do you get this system

  • @trinhyang427
    @trinhyang427 8 ปีที่แล้ว +2

    Can you please provide the damper/ control brand name? Thanks in advance.

    • @degreer1984
      @degreer1984 8 ปีที่แล้ว

      3:40 will give you the damper brand and model. Controller should be found via a quick google search for the brand.

    • @weiyanyin3801
      @weiyanyin3801 8 ปีที่แล้ว

      I am also interested in modifying HVAC system in this way. What is the brand of your choice for damper and controller? Thanks

  • @imreb321
    @imreb321 7 ปีที่แล้ว +28

    23 dampers at what? 75$ each? ouch

    • @elooney85
      @elooney85 6 ปีที่แล้ว +3

      I looked up the company... Currently $238/ea for 8" dampers, and minimum $350 for the control board makes it $5,812

    • @revelations4396
      @revelations4396 5 ปีที่แล้ว

      @@elooney85, I just looked up that company. Website is partially hacked.

    • @pit95tav
      @pit95tav 4 ปีที่แล้ว +1

      All for a bit of tin with a servo on it. I wonder how much the control board is by itself.

    • @michaelesposito2629
      @michaelesposito2629 4 ปีที่แล้ว

      E.Looney 😂😂😂

  • @MoonLiteNite
    @MoonLiteNite 5 ปีที่แล้ว +3

    @5:35 whole reason i came to this video... and they blow right over it :(

  • @domorin
    @domorin 5 ปีที่แล้ว

    and what about half closing your registers on the first floor and fully open the ones on the second floor...? I thought that was the purpose of being able to adjust the register...???

    • @whiffytube4640
      @whiffytube4640 5 ปีที่แล้ว +1

      DoMorin very noisy and can lead to condensation on grills which contributes to mold

    • @abacab87
      @abacab87 2 ปีที่แล้ว

      It does work, I just put an extra couple runs in the basement to prevent too much pressure and noise.

  • @meerscan9101
    @meerscan9101 8 ปีที่แล้ว

    yee haw, this old house coming to oahu! they can do a filming on jalousie windows, how to plant a papaya tree, and install a washer machine plumbing outside on back patio, oh yeah, and what is this gadget??

    • @thisoldhouse
      @thisoldhouse  8 ปีที่แล้ว +1

      +refrigeration tech Hi there, submit your requests here for a chance to land on Ask TOH! asktoh.thisoldhouse.com/toh/asktoh/question.jsp

  • @vakouxiong2028
    @vakouxiong2028 6 ปีที่แล้ว

    What's available out there for zoning a boiler system?

    • @andrewjackowitz3548
      @andrewjackowitz3548 5 ปีที่แล้ว

      Zone valves or separate circultors with anti convection valves and control board

  • @DianaAlhhelou4
    @DianaAlhhelou4 3 หลายเดือนก่อน

    im kind of confused

  • @brainwashingdetergent4322
    @brainwashingdetergent4322 5 ปีที่แล้ว +2

    The cheese is strong in this one!

  • @elvis765
    @elvis765 4 ปีที่แล้ว

    I have a zoned system and it sucks upstairs as it does not maintain the set temp. May need to have a load calculation done to see if system needs to be re-sized $$$ had to replace all of my damper motors cost more than 75.00 🤑

  • @mcorsello216
    @mcorsello216 8 ปีที่แล้ว +3

    pretty sure this is a repost. watched this clip on TH-cam a while ago

  • @HsingSun
    @HsingSun 4 ปีที่แล้ว

    The Forced-Air Furnace system is controlled by an electronics board only work good in lower lighting areas. In Florida, I would not use them because there are many lighting.

  • @tylerfriesen77
    @tylerfriesen77 5 ปีที่แล้ว +1

    If you are going to zone a system do it right and not like this. Go for 2 stage equipment with variable ECM motor and 2 stage AC. Or else you can run into high limit and freeze ups. This is a hack way to do it.

    • @davidrowlett2896
      @davidrowlett2896 3 ปีที่แล้ว

      2 STAGE WONT GUARANTE ANYTHING.. A lot of time 2 stage kicks in High too quick and still have high static and oversize complete Variable system is best but who can afford them

    • @tylerfriesen77
      @tylerfriesen77 3 ปีที่แล้ว

      A proper zone system designed to work with the equipmemt will allow full system control. Lennox harmoney systems have their own limits and safetys to prevent freeze ups and staging control. Do some research.

  • @jessec.9295
    @jessec.9295 6 ปีที่แล้ว

    Title 24 says you need tape

  • @Mike_Greentea
    @Mike_Greentea ปีที่แล้ว

    That wasn’t cheap !

  • @TheOriginalBumper
    @TheOriginalBumper 4 ปีที่แล้ว +1

    Waaaaaaay too many moving parts. I have a similar system in my house and it’s 100 percent Garbage . If a company tells you that this an option and they want to install Ruuuuuun away as fast as you can

    • @jokawild187
      @jokawild187 4 ปีที่แล้ว

      True. I've installed lennox xc20s and xc25s on peoples home and just the amount for a 5ton zoned system was over 20k and they are a piece of crap, yes I'll admit it does what you want to do but for that amount your better off getting 2 basic system for a less and lasts longer then those xc series

    • @thomaslascola2698
      @thomaslascola2698 3 ปีที่แล้ว

      Well there are better systems why you have to do homework.. my boss does a system that uses air bladders to block the flow withpneumatics. The system actually works great.. did you buy the house eith the system already there or did you have it done..

    • @TheOriginalBumper
      @TheOriginalBumper 3 ปีที่แล้ว

      The home is a new build and it was finished in early 2020, another problem I found with these systems is that if for some reason the upstairs gets hotter than the lower level and you need the heat on downstairs and the ac on upstairs you can’t do it. That alone is a reason not to use it. As strange as that sounds I’ve actually ran into that problem a few times .

  • @LordGooben
    @LordGooben 7 ปีที่แล้ว +1

    his comm closet is killing me

  • @patrickburke1020
    @patrickburke1020 3 ปีที่แล้ว

    Maybe not such a good idea to put a bypass in so close to the return...can superheat the return air in the winter (and cause the furnace to shut down prematurely) or supercool it in the summer (and freeze the evap coil). Put in bypass dampers on some/all the branches. Same $ and prevents accelerated wear & tear on the expensive furnace and evap components.

    • @BrandonVincent1
      @BrandonVincent1 3 ปีที่แล้ว +1

      I'm no professional by any stretch of the means, but this was the first thing I thought when he described what that did.

    • @cadets3
      @cadets3 2 ปีที่แล้ว

      Personally, they should have just used the basement as a dump zone for all that extra air. There, solved.

    • @abacab87
      @abacab87 2 ปีที่แล้ว

      @@cadets3 I dump most of my air in the basement, then it works it's way up to the first floor through convection, as well as the ducts. The furnace runs longer so the upstairs gets more heat. I just did that without any dampers, but will just shut ones off to one area if another area is cold. I really like having a warm basement, and the heat is much more even on the first floor. In the winter I shut off most of the runs in the basement and let most of it go to the upper floors.

  • @amahana6188
    @amahana6188 3 ปีที่แล้ว

    Plastic zip ties? Really? Those things will last less than a year before they are so brittle every last one will have snapped in half.

  • @AC-SuperCool
    @AC-SuperCool 7 ปีที่แล้ว +6

    Hackery at its finest...

    • @ruffxm
      @ruffxm 7 ปีที่แล้ว

      What would be the solution aside from having a separate A/C compressor and furnace for each floor? Like everyone can shell out 15-20k in parts and labor to add that, right?

  • @DianaAlhhelou4
    @DianaAlhhelou4 3 หลายเดือนก่อน

    skibidi!

  • @talljohn5350
    @talljohn5350 7 ปีที่แล้ว +2

    terrible way to zone. and bypasses are a really bad idea. if you have a single stage system deal with the extra noise or risk overheating/freezing your coil, along with killing your systems efficiency. Best advice is to have registers with big spaces that don't restrict airflow. Also extra velocity can be a good thing if you're properly directing airflow based on the location of your registers. It will get the hot/cold air to where it needs to be verses going where it wants based on convection, and will help mix the air creating a more uniform temperature in your home. At the end of the day there are better solutions but if you're retrofitting a single stage system, there are no guarantees zoning will be a great solution, but it can work just do not make more than 2 zones, and monitor your system to make sure the decreased air flow doesn't cause overheating or freezing of your coil. NEVER DO A BYPASS!

    • @MarkMark-kq6mc
      @MarkMark-kq6mc 5 ปีที่แล้ว +1

      talljohn5350 - I agree with your comments. Have to make sure the minimum airflow requirements for heating and cooling are met when the smallest zone is calling otherwise will have issues with high limits in heating and ac freezing in cooling mode. But hey what do I know, I’m just a Carrier factory trained technical support specialist.

    • @boby115
      @boby115 4 ปีที่แล้ว

      @@MarkMark-kq6mc , I couldn't agree with you more. I am amazed at some of the contractors that install these things and don't have a clue about temperature rise or how to take it or even how to locate it on the manufacturers plate. I yet to see one of these videos where the installer took the temperature rise after the installation was completed. But hey what do I know, I am just a first responder / HVAC technician for a gas utility with 35 years of experience.

    • @cjimcook
      @cjimcook ปีที่แล้ว

      @@boby115 I'm guessing this is an older episode, judging from Richard''s youthful appearance. Really, they are trying to retrofit an existing old system at low cost with the tools they had at the time, maybe. Even with the bypass, what hits me is that you have an HVAC system that is either over-sized or under-sized given how many dampers are open or closed. Plus, we've all read about proper sizing to avoid excessive on/off cycles. So, what is the solution for an existing home? And what is the solution for a new home?

  • @DianaAlhhelou4
    @DianaAlhhelou4 3 หลายเดือนก่อน

    what the

  • @testthisfordecficiencies
    @testthisfordecficiencies 4 ปีที่แล้ว +1

    What a jerk, the next person gets lacerations when working on the ducts. Cut the zip ties flush.

  • @zack9912000
    @zack9912000 8 ปีที่แล้ว +1

    Every time he talks about HVAC I cringe, he is what we call a hack

  • @kryptoknight.
    @kryptoknight. 6 ปีที่แล้ว

    What a pain in the neck!

  • @DianaAlhhelou4
    @DianaAlhhelou4 3 หลายเดือนก่อน

    hehehe

  • @Zamoramax6.6
    @Zamoramax6.6 7 ปีที่แล้ว

    Ask how to hack this old house