Is inverter ke sath jab wapda ko on karte hain to metre Mein reverse light on ho jaati Hai aur Agar inverter ko bypass kar do to fir on Nahin Hoti aap iska koi HAL bata sakte hain
@@saadhasan6612 Agar apka ke paas panel hai to apkp chahiye ke 70 percent panel pv2 par lagai maximum 550 volt tak lagasakte hain. 30 percent pv1 par kyonke inverter. Pv1 apne power keliye use karta hai or Pv2 load keliye. Agar battery ya wapda ho to phir dono string load keliye use karta hai
Bhai ek issue ha setting sbu ha inverter jub day time run krta ha tu sath 2.3 app wapda protector py show hota ha jub ky inverter py jo wapda hoti ha wo zero show hoti ha ecka koi hal bata dyn
If i take a connection for AC load without batteries from inverter, so it will run the ACs load in day time, what if at night will our ACs will work on single source wapda from inverter ? ......did you check it ?
Yes and if you have panels maximum panel should be series in pv 2 because it take pv1 only to start inverter if you dont have wapda. If wapda is there than it is using both string if no wapda it will use only string 2 for load and string 1 for inverter power. For example if you have 10 panels 7 panels should be on pv2 and pv1 3 panels
Dear Sir, need your kind advice please. I have recently installed a 6kw solar system through a vendor in Peshawar. We have installed the same Solax 6kw Hybrid Inverter with 12 N-Type A grade 585w solar panels (which makes it a 7kw). We have not installed a battery yet because there is only 3 hours of loadshedding in my area during the day time (and I ran out of budget as well). It shall be noted that I have only two 1.5 ton Full DC inverter ACs, a normal size fridge, 3 ceiling fans (60w), and some light. The average load of the house is around ~3.5kw. Suppose at 10:56am when the solar system is producing power at peak level, it would be supporting the entire load of the house and even exporting some to the Green Meter as well (which is yet to be installed). Now the problem is that as the grid goes off at 11am (loadshedding), the inverter would trip and would show DCBUS_SW_UVP error on it. It then restarts and immediately trips again and continues unless I manually go and switch off the both ACs and the Fridge. I contacted the vendor many times and they visited many times but could not fix it. Today they shared that it is the nano-second torque of the ACs, and probably the Fridge, that trips the inverter and does not let it the PV's increasing flow to the inverter. They recommended that you should install (min 48v) battery/batteries to help with the torque to have the system running and pass through without tripping. Can you please help? What should I do?
Fahad Brother did you find the solution for the problem you have mentioned? I need your advise as I am also from Peshawar and going to install same as yours solar system with 10 Canadian Top-Con Solar panels and Solax 6KW hybrid inverter.
I am also from Peshawar… looking to install the same inverter with 16 Inverex panels of 575 watt.. but i am so confused regarding inverter as will this inverter work without battery and by cutting off wapda or not..?
@@ArmaghanSaqib sir thank you for your video sir my solax invertor is showing me 370 volt but not taking electricity from solar panel taking it from KE What is the reason
Maximum string should be on pv2 and pv1 minimum string. For example if you have 12 panels 8 panels should be on pv2 and 4 panels on pv1. Because without wapda pv1 is not using only it will power inverter. If you have 11 panels. 8 panels on pv2 and 3 panels on pv1
Assalaam o alaikum. We have installed this but when wapda turns on solar power completely stops and it shows power is only drawn from wapda. When wpada turns off it starts drawing power from solar.
@@GHOSTBOSS212 us se kam he lekin yeh ek ajeeb noise he iska fan neeche se hawa le kr ooper se nikaalta he jis se ajeeb awaaz nikalti jo km to hoti he lekin sar dard karti
sir ye inverter mai nay lgaya hai is mai ak issue a rha hai soler or batry k sath ye wapda shearing kerna shoro ker deta hai full doop mai b 3 amp wapda say leta hai inverter per 0 dikhata hai kisi bhai ko pata hai k keya problem
Assalamualikum Sir my solax inverter is not generating power zero watts after the setting made by electrician And also plz guide how to check its extra generating units will reversed to wapda or not
Assalam o alaikum. I recently have installed Solax 6kva inverter, I tried to install the software from the usb but nothing happened. Do you need to do something to detect it?. Secondly in my Fronus Solax inverter the WiFi does not have the antenna, has it been removed, box was apparently sealed packed.
You have to put Software Usb first than turn on the inverter, system will automatically detect the Usb and for Wifi device it doesn't come with antenna nowadays you can directly connect them to your router..👍
محترم اسلام علیکم اگر سولیکس انورٹر کو بغیر بیٹریوں کے سولر پر چلائیں تو واپڈا کی لوڈشیڈنگ ہو جائے تو کیا اے سی سولر پر چلتا رہے گا یا بند ہو جائے گا. مہربانی فرما کر میرے سوال کا جواب دیجئے.
Yes but 10 plates should be connected to pv2 and 4 to pv1. Then it will work without wapda and batteries. If you are using battery then 7 on pv1 and 7 on ov2
Battery zarori nahi hai. But grid should be present for stable operation. It can run on only solar but then load should be about half than the PV output at that time.
main kal yeh install karvawa hia . solar aur bettry per theek chal raha hia . lekan jab wapda on karte hian yeh bettry or load ko wapis wapda per export kar raha hia . humne export bhi off ki hoi hia . installer ko bhi samaj nhi aa rahi kindly help.
Have you followed these 3 steps? (1) CT installation on wapda live (2) Enable 'No export' setting in inverter (3) Enable CT setting in inverter from None.
Bhai bahut say installer's ko inverters ki settings ka pata hi nahe vo bus wiring waghaira kr letay hain us kay baad bhagnay ki krtay hain, yeh to Allah ka shukar hay hum khud hi inverter ki setting main ja kr aur user manual parh kr kuch na kuch setting kr letay hain otherwise installer to Allah maaf karay ziyada tar non professional hain.
Yes. But one problem if you are using without wapda and batteries then if you have10 panels or 12 panels. 70 percentage of panels should be attached to PV2 and 30 percent on PV1. BECAUSE INVERTER IS NOT USING PV1 WHEN THERE IS NO WAPDA OR BATTERIES. IT WILL JUST POWER ITSELF ON PV1
Inverex and Solarmax are also good but 100k expensive. I have found Solax much better though as it allows12 kw torque load for upto 10 seconds. Which means all your old A/Cs, fridge and other appliances can work.
580 watts should work. I am using Trina 595 watt double glass panels without any problem. I have run a/c with wapda but should run without wapda too. Will test and share results. Also I ran a non-inverter 2 ton a/c and it ran fine.
I don't understand why you bought a hybrid inverter. If I'm not mistaken there are also on-grid inverters that can operate off-grid (in island mode); I know for sure that microinverters can do this. On-grid inverters are cheaper than hybrid inverters and more efficient, because the hybrid inverter will first use an MPPT to bring the voltage down to a battery charge range and then the inverter has to modify it up again to grid voltage. This causes additional losses, compared to an on-grid inverter that can transform the voltage from panel DC voltage straight to AC. With microinverters you'd also have AC available when the grid goes down during the day.
Bhai agar on grid inverter letay to agar din mien wapda jati to in ka solar setup or 4 ac jo chalany hien inhon ne wo band ho jaty chahaye kitni b bahir dhoop nikli hoti. Isi liye hybrid liya hai bhai ne ta k wapda ho ya na ho din mien solar chalta rhay ac chaltay rhien din mien wapda ho ya na ho. Jab k on grid inverter wapda k baghair nahi kaam krta din mien b usay wapda chaiye hoti hai. Light janey pr wo din mien b band ho jata hai.
@@vitalfarms7534 I think you can buy separate electronic systems to disconnect from the grid automatically when the grid goes down. A hybrid inverter has such a system integrated.
I have to attach batteries after few months so that is why I have purchased hybrid one. In addition, it works without grid too. I could not find any on-grid inverter which could work in what you call 'island' mode. If you know one, let me know. There are solutions with switches and relays to activate an additional hybrid inverter when grid is off but why complicate life?
@@ArmaghanSaqib Yes, if you add a battery later then this is a very good solution. Most micro inverters can operate in island mode. I've seen an on-grid inverter that can operate in island mode, but they are quite rare.
@@KashifKhan-1760 hona chaye agher nahi ho Raha to software upgrade karwain company ki website site pa ja k complain karain wo online hi upgrade karwain gain ap ki wifi connect honi chahye net k sath
Solax is an international brand being used in many countries around the world where as Inverex is a local brand. So far in my experience it is quite robust. And price difference is also really big; around 100k cheaper than nitrox.
Assalam o Alaikum hru sir main Solax power 6kw use kar raha hun 1 week pahlay instal karwaya hai aj 1st tme light gai hai to inverter solar par nai chala har cheez 00 ho gai main nai battrey nai lagai ab kia kiya k direct solar par load uthai jab light jai to @@muhammadafzaal8670
@@AnayaTawanbattery 🔋 lagai apny isky sth? If battery 🔋 fit hai Apke system Mai phir work kryga agar battery 🔋 NAHI hai to KE off Hogi to apka solar system BHI off hojay ga. Ek support lazmi chahiyae Inverter ko working on rakhny KY liyae.
Fan is in heat sink and outside main body. It starts running when inverter heats up; usually when you put lot of load or in very warm weather. Otherwise it stays silent. I have Inverex 3.2 and Solax in same room. I can hear the sound of Inverex but Solax stays silent mostly.
I am in Lahore. Please search Internet for suppliers. Hopefully you should get it for 270K. Its company/control price is 260K but shops are charging extra.
@@talalakram7 It is better to wait couple of weeks as inverter shipments have started coming in now. Price will automatically go down at dealers too when they will face competition from other brands.
@@ArmaghanSaqib yes of course. I purchased this inverter 2 days before eid. At that time, i approached to SolaxPower Head office by some reasonable source. They clearly informed they are out of stock and restock may take 2 months or more
اچھا انکل جی وہ اپ سے ایک بات پوچھنی ہے کہ ہم نے یہاں پر ایک یہ انونٹر لگایا ہے نہ تو اس کی کچھ پرابلم ا رہی ہے کہ وہ ہم نے نیٹ میٹرنگ نہیں کرائی ہوئی تو تو جو ہمارا واپٹا والا میٹر ہے نہ سنگل والا وہ اس کی فالٹ والی لائٹ بھی ان ہو جاتی ہے اور وہ وہ جو اس کے اندر میٹر کے اندر جو لائٹ ہوتی ہے نا وہ فلیشنگ والی وہ بہت جلدی جلدی کر رہی ہے وہ بہت جلدی ان اف ہو رہی ہے تو اس کا کیا پرابلم ہو سکتا ہے ہم نے اس کے ساتھ بیٹریاں نہیں لگائی ہے تو رہنمائی فرما دیں بہت مہربانی ہوگی
@@ArmaghanSaqib Sir, my maximum PV input was 2200 watt and 600 watt was shared from grid. Maybe that's the reason for the fan on. The ventilation condition is almost the same at my site
Please reply, Solax ke sath 2 battries filhal attach kar sakte hain
2 batteries =(12v+12v) 24volts, required voltage 48volts hay islye 4 batteries chahyain
Is inverter ke sath jab wapda ko on karte hain to metre Mein reverse light on ho jaati Hai aur Agar inverter ko bypass kar do to fir on Nahin Hoti aap iska koi HAL bata sakte hain
Ye Hybrid inverter light Jane pe b chlta rahe GA? Agr batteries na lgai hn tb b?
Assalamualaikum
Bhai AP is ki maximum production share kar sakty aik din ki wapda sharing k Sath?
Sir kia ye inverter grid off hony pr without batteries load chalata hai?
Yes
@@NazeerAhmad-bk1ul heavy and light load dono without batteries
@@NazeerAhmad-bk1ul have u installed this inverter..
12v ki maximum kitny AH ki battery ko support krta hai? Led acid
Sir kia hum CHOTI batteries Laga sakhty Hy 6kw ke system ke sath... 100 amp ki 4 batteries Laga sakhty hy
@@AyaanMalik-t9g ji me NY lagai hui hain 100amp ki.sahi chal Raha ha
A. O. A, es k fan ki awaz kafi thi, aik video main es se net metering kerwa rahy thy tu es ki awaz kafi thi, please inform me.
Sir ye bagir battries or bagir wapda nai chlta ma na install karwaya ha please help??
Sir isko ek power support required hai, Wapda ya battery 🔋 on honey KY liyae. Phor ye Solar Ki power apky ghr Mai supply kryga.
@@saadhasan6612
Agar apka ke paas panel hai to apkp chahiye ke 70 percent panel pv2 par lagai maximum 550 volt tak lagasakte hain. 30 percent pv1 par kyonke inverter. Pv1 apne power keliye use karta hai or Pv2 load keliye. Agar battery ya wapda ho to phir dono string load keliye use karta hai
KITNE PANEL LAGWAYE HAIN
@@NazeerAhmad-bk1ul 11 585
@@NazeerAhmad-bk1ul can u plz guide me i am also looking to install this inverter by connecting 16 575watt panels
Bhai ek issue ha setting sbu ha inverter jub day time run krta ha tu sath 2.3 app wapda protector py show hota ha jub ky inverter py jo wapda hoti ha wo zero show hoti ha ecka koi hal bata dyn
Sir plz reply as my solax is not taking load from solar
If i take a connection for AC load without batteries from inverter, so it will run the ACs load in day time, what if at night will our ACs will work on single source wapda from inverter ? ......did you check it ?
Same question
Yes and if you have panels maximum panel should be series in pv 2 because it take pv1 only to start inverter if you dont have wapda. If wapda is there than it is using both string if no wapda it will use only string 2 for load and string 1 for inverter power. For example if you have 10 panels 7 panels should be on pv2 and pv1 3 panels
Why CTA is important?
Sir kia solar power hybrid inverter without batteries light and heavy load dono chala deta hai?
How much load is consumed by inverter from wapda even if no load is running on it?
Since there are no batteries, what will happen if there's an outage in the night? Will you have to press load reset again and again?
Inverter will simply shutdown if grid goes away at night and will be functional again when grid is back. No need to press load reset.
@@ArmaghanSaqib but my inverter whjen grid is back not start there is show grid power failer
I too have this problem
@@muhammadbilal4441 contact to company and upgrade software
Agar raat ko without batteries aise tang krta hai to phir to masla hai buhat
AOA Sir is mae subha ka time jab solar sa pv power on hoti hai koi error atha hai without battery
Dear Sir, need your kind advice please. I have recently installed a 6kw solar system through a vendor in Peshawar. We have installed the same Solax 6kw Hybrid Inverter with 12 N-Type A grade 585w solar panels (which makes it a 7kw). We have not installed a battery yet because there is only 3 hours of loadshedding in my area during the day time (and I ran out of budget as well). It shall be noted that I have only two 1.5 ton Full DC inverter ACs, a normal size fridge, 3 ceiling fans (60w), and some light. The average load of the house is around ~3.5kw.
Suppose at 10:56am when the solar system is producing power at peak level, it would be supporting the entire load of the house and even exporting some to the Green Meter as well (which is yet to be installed). Now the problem is that as the grid goes off at 11am (loadshedding), the inverter would trip and would show DCBUS_SW_UVP error on it. It then restarts and immediately trips again and continues unless I manually go and switch off the both ACs and the Fridge. I contacted the vendor many times and they visited many times but could not fix it. Today they shared that it is the nano-second torque of the ACs, and probably the Fridge, that trips the inverter and does not let it the PV's increasing flow to the inverter. They recommended that you should install (min 48v) battery/batteries to help with the torque to have the system running and pass through without tripping.
Can you please help? What should I do?
Fahad Brother did you find the solution for the problem you have mentioned? I need your advise as I am also from Peshawar and going to install same as yours solar system with 10 Canadian Top-Con Solar panels and Solax 6KW hybrid inverter.
I am also facing same issue. When there is no electricity from grid. My inverter goes off.
I am also from Peshawar… looking to install the same inverter with 16 Inverex panels of 575 watt.. but i am so confused regarding inverter as will this inverter work without battery and by cutting off wapda or not..?
Also … can u plz tell from where have u bought this inverter and at which price…
Yeh feed-in show kr rha raat ko, jab k mene export 0 kee hui he,
Ap ye without batteries use kr rhy hain ?
assalamOaliekum Armaghan Sahab, Is this a Fan-less (IP65) inverter?
Very interesting setup. Thanks for sharing.
What is the inverter self power consumption from wapa without load?
I have not measured exactly but I think around 50 watt or so. Will check with meter and share exact info again.
@@ArmaghanSaqib sir thank you for your video sir my solax invertor is showing me 370 volt but not taking electricity from solar panel taking it from KE
What is the reason
How two connected both PV on without wapda and battery
Maximum string should be on pv2 and pv1 minimum string. For example if you have 12 panels 8 panels should be on pv2 and 4 panels on pv1. Because without wapda pv1 is not using only it will power inverter. If you have 11 panels. 8 panels on pv2 and 3 panels on pv1
Assalaam o alaikum. We have installed this but when wapda turns on solar power completely stops and it shows power is only drawn from wapda. When wpada turns off it starts drawing power from solar.
Settings main ja k SUB wali option select karo
Best review and analysis.
Thanks
Iski back side py Heat Sink k sath aik fan laga hwa hai jub wo fan chalta hai tu uski awaz ki kitni hai ?
Awaaz to he lekiin agr apko awaz na chaye to nitrox lgao mene abhi lgya he aj solax Lekin ismy noise he lekiin Ziyada nhi he
@@FortniteMaps ip21 ki tarah noise hai ya bilkul normal?
@@GHOSTBOSS212 us se kam he lekin yeh ek ajeeb noise he iska fan neeche se hawa le kr ooper se nikaalta he jis se ajeeb awaaz nikalti jo km to hoti he lekin sar dard karti
@@GHOSTBOSS212 leeya solax apne?
sir ye inverter mai nay lgaya hai is mai ak issue a rha hai soler or batry k sath ye wapda shearing kerna shoro ker deta hai full doop mai b 3 amp wapda say leta hai inverter per 0 dikhata hai kisi bhai ko pata hai k keya problem
Assalamualikum
Sir my solax inverter is not generating power zero watts after the setting made by electrician
And also plz guide how to check its extra generating units will reversed to wapda or not
واپڈا جانے کے بعد آنے کی صورت میں خود سے آن نہیں ہوتا کیا
Is py kitna load run ho skta ha . Number of ACs and fridge ? Or is py without batteries complete load dal k video bnaiay ga. Shukria
yeh C.T KYA KARTI HE?
If you are not doing net-metering then CT helps you stop export from your inverter to the grid.
@@ArmaghanSaqib acha lekiin agr wire hee na lagi ho phir bhi use Hoti he? Mene abhi leeya he solax inverter, to pta nhi mjhe yeh Kya seen he
Sir grid anay jany par output cut Ku Karta ha.plz koi setting batain
Without batteries it is normal
Sir can we run only 1.5 ton ac on this inverter with 6 solar plates?
Yes with wapda sharing
Assalam o alaikum. I recently have installed Solax 6kva inverter, I tried to install the software from the usb but nothing happened. Do you need to do something to detect it?. Secondly in my Fronus Solax inverter the WiFi does not have the antenna, has it been removed, box was apparently sealed packed.
You have to put Software Usb first than turn on the inverter, system will automatically detect the Usb and for Wifi device it doesn't come with antenna nowadays you can directly connect them to your router..👍
@@ittechinchave they removed the wifi dongle
@@ittechincand what's the price now a day
Can you attach net metring
Yes, you can. I have done it and will share a video on this soon.
Ye tu single phase ha
Net metering kesay kerwaye gy
Net metering ho jati hai single phase per. I have done it.
Lahore mn single phase net metering hoti hai brother
Sham ko pv ky voltage nahi hota to inverter on/off hota he ap bataen kia inverter off karden?,battery or grad inverter per in nahi kia he
The best option is to add batteries, even if small capacity. Otherwise you can use a change over to switch to grid completely in the evening.
Does it have facility to change settings from mobile app?
Yes you can
Sir inverter error show kr rha ha...
Startup_condition_fail error......
Kindly mujy batain k ya kesy khytum krn
Sir ye CT connection kia hai solix men? Or ye 1 phase inverter hai?
CT is used to tell the direction of current from grid to inverter.
AoA where from I buy hibride solar power inverter
Aapko mil Gaya ye inverter?
Pv off hotay hi startup condition fail error show karta hay pl reply thanks
Batteries nahi attached ki hon gi na ap ny
SALAM SIR IS KI PV KASAY INSTALLED KARAY MUJHY PV 1 PV 2 KI SAMJH NAI A RAHI PLEASE GUIDE
محترم اسلام علیکم
اگر سولیکس انورٹر کو بغیر بیٹریوں کے سولر پر چلائیں تو واپڈا کی لوڈشیڈنگ ہو جائے تو کیا اے سی سولر پر چلتا رہے گا یا بند ہو جائے گا. مہربانی فرما کر میرے سوال کا جواب دیجئے.
Band ho jye ga
6000 watt se uper wali power ka kia kre ga???
Kia yeh onyx ki trah 150% grid feed kr skta hai??
No. Export max 6000.
I have 14 panels on this inverter. Can produce max 7000 but exports max 6000. Remaining goes to battery if battery needs charge.
DCBUS_SW_OVP &DCBUS_SW_UVP error q ata he?
Longi hemo 5 ki 14 plate k sath aik 1.5ton ac or 2 fridge chal jaye ge without wapda or bettry
Yes but 10 plates should be connected to pv2 and 4 to pv1. Then it will work without wapda and batteries. If you are using battery then 7 on pv1 and 7 on ov2
Price kitni hai?
Bhai ye direct kia apny or poray ghr ka kitna load uthaya isny kia battery zarori h
Battery zarori nahi hai. But grid should be present for stable operation. It can run on only solar but then load should be about half than the PV output at that time.
ye 3 phase inverter hai ya single phase?
Single phase hai.
invertor price?
Ntc sample invalid error
Solax mai 4 kw ata hy?
Slam
Brother inshaAllah zarur kha krain
main kal yeh install karvawa hia . solar aur bettry per theek chal raha hia . lekan jab wapda on karte hian yeh bettry or load ko wapis wapda per export kar raha hia . humne export bhi off ki hoi hia . installer ko bhi samaj nhi aa rahi kindly help.
Have you followed these 3 steps? (1) CT installation on wapda live (2) Enable 'No export' setting in inverter (3) Enable CT setting in inverter from None.
@@ArmaghanSaqib thx for ur help. CT was on wrong direction, now working perfectly 🥰
Bhai bahut say installer's ko inverters ki settings ka pata hi nahe vo bus wiring waghaira kr letay hain us kay baad bhagnay ki krtay hain, yeh to Allah ka shukar hay hum khud hi inverter ki setting main ja kr aur user manual parh kr kuch na kuch setting kr letay hain otherwise installer to Allah maaf karay ziyada tar non professional hain.
@shazaibzia1082 bro. Can jb day time me wapda on ke tou real time sharing krta ha.? Krna Amper leta ha wapda sy?
Solax hybrid Inverter review? Are you satisfied from it regarding it's performance
Yes. But one problem if you are using without wapda and batteries then if you have10 panels or 12 panels. 70 percentage of panels should be attached to PV2 and 30 percent on PV1. BECAUSE INVERTER IS NOT USING PV1 WHEN THERE IS NO WAPDA OR BATTERIES. IT WILL JUST POWER ITSELF ON PV1
Is ki heavy load aur smart load Kai neutral common ho Sakti hai ya separate use Karni paray gi
Seprate hona chae hai
Good question. I am not sure about it as I am using it without batteries. Will check and confirm.
Seperate krye. Wrna jb heavy load cut hoga EPS load b cut ho jy ga. Without batteries bs EPS on hota hai is me
Janab ya display per bhi or mobile aap per b reading sahi nahi dyta waja?
M 265 ka Liya ta bohat acha chal raha 7100 tk lod uthata aram se
Brother kah sai liya hai please share number 𝓳𝓪𝔃𝓪𝓴𝓐𝓵𝓵𝓪𝓱
@@malik8733 abi nai mil Raha 3 m b nai
Without batteries or wapda sharing k sath koi issue to nai aa rha ?
@@tanv33rabbaskindly reply this query
Aoa. What is its price at present. Where is its distributer , more information regarding its warranty and after sale series. Thanks.
I purchased yesterday for 292K. It has 5 years replacement warranty.
@@haseebhashmi4338 ap bhi without batteries use kr rhy hain ?
Assalam o Alaikum
Startup condition fail Ka error araha he is inverter me
Kindly guide karen
Bhai ye lena chaye 6kv mein inverex ya solarmax onyx please reply please
Inverex and Solarmax are also good but 100k expensive. I have found Solax much better though as it allows12 kw torque load for upto 10 seconds. Which means all your old A/Cs, fridge and other appliances can work.
@@ArmaghanSaqib how much panels of 575w i can install with this inverter
@@MAnees-jk5yg atlest 12 13
@@MAnees-jk5ygmax16
YEH SINGLE PHASE INVERTER HAI KIA ????
Yes, it is single phase inverter.
Sir ya 580watt panel support kerta ha or kia aap nY koi ac direct chalY ha
580 watts should work. I am using Trina 595 watt double glass panels without any problem. I have run a/c with wapda but should run without wapda too. Will test and share results. Also I ran a non-inverter 2 ton a/c and it ran fine.
@@ArmaghanSaqibany update
I don't understand why you bought a hybrid inverter. If I'm not mistaken there are also on-grid inverters that can operate off-grid (in island mode); I know for sure that microinverters can do this. On-grid inverters are cheaper than hybrid inverters and more efficient, because the hybrid inverter will first use an MPPT to bring the voltage down to a battery charge range and then the inverter has to modify it up again to grid voltage. This causes additional losses, compared to an on-grid inverter that can transform the voltage from panel DC voltage straight to AC. With microinverters you'd also have AC available when the grid goes down during the day.
Bhai agar on grid inverter letay to agar din mien wapda jati to in ka solar setup or 4 ac jo chalany hien inhon ne wo band ho jaty chahaye kitni b bahir dhoop nikli hoti. Isi liye hybrid liya hai bhai ne ta k wapda ho ya na ho din mien solar chalta rhay ac chaltay rhien din mien wapda ho ya na ho.
Jab k on grid inverter wapda k baghair nahi kaam krta din mien b usay wapda chaiye hoti hai. Light janey pr wo din mien b band ho jata hai.
@@vitalfarms7534 I think you can buy separate electronic systems to disconnect from the grid automatically when the grid goes down. A hybrid inverter has such a system integrated.
I have to attach batteries after few months so that is why I have purchased hybrid one. In addition, it works without grid too. I could not find any on-grid inverter which could work in what you call 'island' mode. If you know one, let me know. There are solutions with switches and relays to activate an additional hybrid inverter when grid is off but why complicate life?
@@ArmaghanSaqib Yes, if you add a battery later then this is a very good solution. Most micro inverters can operate in island mode. I've seen an on-grid inverter that can operate in island mode, but they are quite rare.
There is SOFAR solar company inverter which is on grid inverter but works on off grid as well there is a mode for the purpose..
Does it work without battery?
Yes, works perfectly without battery.
Wapda on off honay pe load trip to nahi hota for 1-2 seconds? Meaning k aik bar off ho k dobara start ho jaye
I have same inverter installed with out batteries during night it makes issue of starting
@@BabyTaimurpsh without battery?
@@BabyTaimurpshplease share number
@@BabyTaimurpshواپڈا جانے کے بعد آنے کی صورت میں خود سے آن نہیں ہوتا کیا؟
@@KashifKhan-1760 hona chaye agher nahi ho Raha to software upgrade karwain company ki website site pa ja k complain karain wo online hi upgrade karwain gain ap ki wifi connect honi chahye net k sath
Mainy suna
10ah Wali 4 small batteries b lga skty.
Agr apko pta tu guide kr den
Not sure.
Is per stable load kitna chal sakta he maximum
Upto its capacity or a little more even. But it is always recommended not to push the limit of any inverter. Better to stay under 6 kw.
Bhai plz guide me technical comparison Solax Vs inverex nitrox
Solax is an international brand being used in many countries around the world where as Inverex is a local brand. So far in my experience it is quite robust. And price difference is also really big; around 100k cheaper than nitrox.
A. A jab es per load dala to awaz ati ha y nahi
Heavy load may heat it up and fan will start.
A. A bhi is inverter ki WiFi setting Ka tariqa bats fain
Is ki WiFi setting ni ho rhi
Assalam walekum sir sir kindly yah bataen ki 6 6 kilowatt ke do inverter ek hi metre ke sath kaise install kiye jaate Hain please lajmi reply kijiega
Sir is there any Solax service centres available in Pakistan? if yes then which cities they have service centres.
Currently in Lahore and will expand to other main cities of Pakiatan.
yeh IP 65 ha ?
Yes
Assalam o Alaikum hru sir main Solax power 6kw use kar raha hun 1 week pahlay instal karwaya hai aj 1st tme light gai hai to inverter solar par nai chala har cheez 00 ho gai main nai battrey nai lagai ab kia kiya k direct solar par load uthai jab light jai to @@muhammadafzaal8670
@@muhammadafzaal8670ager apna no share kar dain to maharbani ho gee
@@AnayaTawanbattery 🔋 lagai apny isky sth? If battery 🔋 fit hai Apke system Mai phir work kryga agar battery 🔋 NAHI hai to KE off Hogi to apka solar system BHI off hojay ga. Ek support lazmi chahiyae Inverter ko working on rakhny KY liyae.
Sir aj hi solax installed kiya ha .. Sham ko pv jana ka bad error dey raha ha. Startup condition fail..
Kindly help me out how to resolve it
Have you solved it?
@@heapsofttech not yet
The same error I have too
Same error I am facing
Same error I have
Any solution?
السلام علیکم سر کیا حال ہے ٹھیک ہیں
Sir is ka model number kia hain ?
x1-hybrid-6.0-lv
raat ko to light janay par band ho jay ga
At what time u r doing this test
برادر solax inverter کم سے کم کتنے کلوواٹ تک آتے ہیں۔
I could not find less than 6kw in Lahore but company also build smaller ones like 3.2 kw as I saw on their website.
جناب کتنے کا ہے
iska fan har waqt chalta rehta? aur noise kitni hay
Fan is in heat sink and outside main body. It starts running when inverter heats up; usually when you put lot of load or in very warm weather. Otherwise it stays silent. I have Inverex 3.2 and Solax in same room. I can hear the sound of Inverex but Solax stays silent mostly.
Aoa sir Wi-Fi kase contacte karna ha?
gi
Kis city se han sir ap ma ne b lena ha agr koi 270k ma offer kr rha ha to plz mujy bta de ma ne lena ha
Assalamyalykom app kis City se hai
I am in Lahore. Please search Internet for suppliers. Hopefully you should get it for 270K. Its company/control price is 260K but shops are charging extra.
@@ArmaghanSaqibyes but company stock has been ended before eid. And restocked in about 2 months. You have to buy from dealers etc.
@@talalakram7 It is better to wait couple of weeks as inverter shipments have started coming in now. Price will automatically go down at dealers too when they will face competition from other brands.
@@ArmaghanSaqib yes of course. I purchased this inverter 2 days before eid. At that time, i approached to SolaxPower Head office by some reasonable source. They clearly informed they are out of stock and restock may take 2 months or more
اچھا انکل جی وہ اپ سے ایک بات پوچھنی ہے کہ ہم نے یہاں پر ایک یہ انونٹر لگایا ہے نہ تو اس کی کچھ پرابلم ا رہی ہے کہ وہ ہم نے نیٹ میٹرنگ نہیں کرائی ہوئی تو تو جو ہمارا واپٹا والا میٹر ہے نہ سنگل والا وہ اس کی فالٹ والی لائٹ بھی ان ہو جاتی ہے اور وہ وہ جو اس کے اندر میٹر کے اندر جو لائٹ ہوتی ہے نا وہ فلیشنگ والی وہ بہت جلدی جلدی کر رہی ہے وہ بہت جلدی ان اف ہو رہی ہے تو اس کا کیا پرابلم ہو سکتا ہے ہم نے اس کے ساتھ بیٹریاں نہیں لگائی ہے تو رہنمائی فرما دیں بہت مہربانی ہوگی
Issue resolved or not?
Ji bhai mujhe 270 ka mila mere bhai ka liya
From where?
@@Majidfazal01 hyderabad se
💯👍
اور انکل جی اگر اپ اپنے کانٹیکٹ نمبر دے دیں تو بہت اچھا ہوگا کہ ہم اپ سے صحیح طریقے سے پوچھ سکیں گے اور سمجھ سکیں گے
Please share your question here and I will reply.
CT direction always keeps towards the inventor, so please change the direction of CT towards the inventor ..
No. It should be towards grid. Check official installation video here: th-cam.com/video/3HAEPBqPol0/w-d-xo.html
Comments
Uncle hamne g klo ward ka solex hybrid inverter Jab Wapda Chali jati hai
I recently installed this model yesterday. I have some issues. Kindly if you provide your WhatsApp Please
Please share issues here and I shall try to help.
Assalam o Alaikum
Sir startup condition fail Ka aerror araha he kindly guide
Solax lithium battery ki kia kimat ha aur munasib rate par kaha milti ha
aur us jaga ka phone number send kara
Sir ap ka contect number mil skta ha kya
Phone number ?
Bhy ap ka watsap nmbr
Agar aap install kartay hein tou kindly share your number
startup condition fail error ata ye kyn hy?????????????
With out battery install kia brother?
@@product_tales gg
Assalam o Alaikum
Bhai is fault Ka solution Mila aapko?
@@muhammadibrahimkhan309 no
A. A jab es per load dala to awaz ati ha y nahi
Ive tested, jb 2800 watt k kreb load jata hai to awaz ati hai light c fan ki. Kreb khry ho k ghor kro tb feel hoti h
I have tested with 3400 watts load and it was still completely silent. I have installed it in open (but covered) space where air flow is good.
@@ArmaghanSaqib Sir, my maximum PV input was 2200 watt and 600 watt was shared from grid. Maybe that's the reason for the fan on. The ventilation condition is almost the same at my site
@@talalakram7 why is mine making lots of noise ? then?
@@ArmaghanSaqib why is mine making lots of noise at 1000 watts ?