How to add/configure/test analog input module of PLC S7-300 SM 331-7KF02-0AB0 by using Simatic V5.6

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ก.พ. 2021
  • Hello TH-camrs and Programmers,
    Today I have one video for show and share about how to add/configure/test analog input module of PLC S7-300 SM 331-7KF02-0AB0 by using software Simatic Manager V5.6.
    In this video everyone will understand about how to use software Simatic Manager V5.6 to add and configure the Analog input module of PLC S7-300 and testing with the real PLC with multimeter.
    If everyone have any questions please kindly drop comment under my videos or contact me by:
    / plc.scada.7564
    Link below is related to PLC S7-300 programming:
    Simatic Manager how to create Function "FC" for Analog Input part2
    • Simatic Manager how to...
    Simatic Manager how to create Function "FC" part1
    • Simatic Manager how to...
    Simatic Manager how to create Function "FC" part2
    • Simatic Manager how to...
    Read data from encoder by using PLC S7-300 CPU314C-2PN/DP part1
    • Read data from encoder...
    Read data from encoder by using PLC S7-300 CPU314C-2PN/DP part2
    • Read data from encoder...
    How to create PID control on Simatic Manager and connect to PLC S7-300 CPU 314C-2PN/DP
    • How to create PID cont...
    PLC S7-300 CPU 314C-2PN/DP Analog Output explanation and testing with real PLC
    • PLC S7-300 CPU 314C-2P...
    PLC S7-300 CPU 314C-2PN/DP Analog Input explanation and testing with real PLC
    • PLC S7-300 CPU 314C-2P...
    PLC S7-300 CPU 314C-2PN/DP hardware configuration using LAN cable
    • PLC S7-300 CPU 314C-2P...
    Simulation Simatic Manager V5.6 with WinCC Flexible 2008 SP5 connected to PLC S7-300 CPU 315-2DP
    • Simulation Simatic Man...
    SIMATIC Manager V5.6 Uploading/Downloading program from PLC S7-300 model CPU315-2DP
    • SIMATIC Manager V5.6 U...
    Hardware configuration between PLC S7-300 with software TIA Portal V15.1
    • Hardware configuration...
    Link for all playlist:
    • PLC SIEMENS Programming
    Thanks you so much for watching my video.
    I'm so sorry if I have mistake in this video.
    Please like share and subscribe my video also to get new notification and new videos.
    Good luck for everyone!
    See you next videos.

ความคิดเห็น • 38

  • @immadhussain4319
    @immadhussain4319 2 ปีที่แล้ว

    4 wire configuration not found in your vedios

  • @bahaagamal4995
    @bahaagamal4995 3 ปีที่แล้ว +1

    Thank you very much for this video , all your videos are very valuable.

  • @reybisdak9488
    @reybisdak9488 3 ปีที่แล้ว +1

    Thank you for Response Sir.

  • @reybisdak9488
    @reybisdak9488 3 ปีที่แล้ว +1

    Excellent video Sir.i believe this is a complete tutorials hehe.

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 ปีที่แล้ว +1

      Dear sir,
      For PC we used other software like Modicon... or some software that can link with PLC S7-300.
      Thanks

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 ปีที่แล้ว +1

      My pleasure!

    • @mehdibessaad3388
      @mehdibessaad3388 3 ปีที่แล้ว +1

      Why the led sf is on?? Do you have any problem??

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 ปีที่แล้ว

      @@mehdibessaad3388 Dear sir,
      Because some configuration of channel not correct sir like selection hardware to voltage but configuration amp it will has some fault.
      But we can use it for other channels that we make correct configuration.
      Thanks!

    • @reybisdak9488
      @reybisdak9488 3 ปีที่แล้ว

      Input analog sir you used potentiometer sir to adjust 4 to 20ma.hehe pls show in the camera Sir.thank you Sir.

  • @sinanartemis6176
    @sinanartemis6176 2 ปีที่แล้ว +1

    hello sir,
    thanks foe tour great videos
    ı have the same analog module
    ı had a temperature transmitter 2 wire 4-20ma output
    ı set everyting the same with you
    and ı wired m+ to my transmitter positive and m- to my transmitter negative ı saw 32767 value or -32767 İ am not sure what is the problem.
    ı saw when ı put a multimeter between analog card ma- pin and transmitter- pin ı saw 6ma value
    what is the problem what is my mistake

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  2 ปีที่แล้ว +1

      Dear sir,
      Thanks, please check your selection between hardware and software for setting.
      What software that you use? TIA Portal or Simatic Manager?

    • @sinanartemis6176
      @sinanartemis6176 2 ปีที่แล้ว

      @@generaltechnologyknowledge5165 ı use simatic manager ı selected 2 wire configuration on software as you showed

  • @suriyat8773
    @suriyat8773 2 ปีที่แล้ว

    How to absulte Encoder thank you

  • @gabrieldamore1307
    @gabrieldamore1307 ปีที่แล้ว +1

    I have a problem: I set the range from 0 to 100% for example, Why when I do the test if I put 0 as a value It gives me 3.5 mA and if I put 100 It gives me 17.5 mA on the tester. The only difference with your settings, Is that i set 2 wire configuration and not 4 wire.

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  ปีที่แล้ว

      Dear sir,
      First please check the configuration of hardware such as connections, power supply 24VDC?
      Second please check the scale setting of 2 wire and 4 wire of scaling block and test again.
      Thanks

  • @ramcom8113
    @ramcom8113 2 ปีที่แล้ว +1

    Hello. Do somebody want to buy 6ES7331-7TF01-0AB0?

  • @devincortez9312
    @devincortez9312 ปีที่แล้ว +1

    None of the lights are changing on your analog input module, how do you get them to show up?

  • @sujitkumarsantra5996
    @sujitkumarsantra5996 3 ปีที่แล้ว +1

    Can i replace an AI module for a Running system? If I want to replace an AI module with a same new module in an Running system then what to do?

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 ปีที่แล้ว

      Dear sir,
      We cannot do it with running system.
      Please do it with stop system. Because it will effect to other modules or other machines during running. I'm not recommend to replace during running system.
      Safety first!
      Thanks you!

    • @sujitkumarsantra5996
      @sujitkumarsantra5996 3 ปีที่แล้ว +1

      @@generaltechnologyknowledge5165 it's ok,But if I do then what types of problem can be occurred?;and what types of fault can be create?

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 ปีที่แล้ว

      @@sujitkumarsantra5996 Sorry sir,
      Please detail the problems! what is the fault?
      Thanks you!

  • @somnathwaghmare51
    @somnathwaghmare51 3 ปีที่แล้ว +1

    Same analog configuration and it's used two wire thermocouple sensor at each 8 channel
    I'm facing SF singnal even having 24v supply at pin 1 and 20
    Please is their anything else to check

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 ปีที่แล้ว

      Dear sir,
      Please check software configuration on each channel must be the same as hardware selection.
      Thanks

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 ปีที่แล้ว

      Anyway I will create more video about how to connect Thermocouple with two wire connection for you.
      Thanks

    • @somnathwaghmare51
      @somnathwaghmare51 3 ปีที่แล้ว

      @@generaltechnologyknowledge5165 thanks for reply sir
      Actually it's running system for long time and suddenly all 3 AI module has SF fault and online diagnostic module status is ok

    • @somnathwaghmare51
      @somnathwaghmare51 3 ปีที่แล้ว +1

      @@generaltechnologyknowledge5165 it's always appreciated efforts to guide us thank I hope it's will helpful to

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 ปีที่แล้ว

      @@somnathwaghmare51 My pleasure!