LP Bypass | HP Bypass | Purpose of LP Bypass and HP Bypass in Power Plant |
ฝัง
- เผยแพร่เมื่อ 13 เม.ย. 2023
- Hello friends,
"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
Email
powerplantdiscussion@gmail.com
Website
/ @powerplantdiscussion (Company Website)
LinkedIn
/ power-plant-discussion...
#powerplantdiscussion
#lpbypass
#turbine
Thanks to all of you for connecting me.
Aap ka samjhane ka tarika bahut accha h
👍
Very Nice Sir
Nice 👍
Very good.
Thanks for clarifying my concept sir 🎉🎉
Very impressive session sir
Nyc video guru
Thanks boss
Mai ntpc plant me operation department me kam karta hu operator ka mujhe achha laga apka vdo
👍👍👍
Very good video
Make a video for interview preparation for 7 years of experienced engineer in NTPC in operation and maintenance.
Sure
Super video
Please make video on steam leakage calculation in plant kg/hr
Sir please make a vedio on Turbine forced cooling process
Startup vent kis purpose k lie hote hain koi video hay kia?
More about centerifugal compressor operating system and parts
Make a video on RLA
Sir what about vacuum . It may cause vacuum dropage from LP bypass??
Sir aap boiler opretor interview ke bare me ve batae
Time to come on shorts sir
Sir Please make a seperate Video on Emergency Handling.. For Boiler and Turbine Both Side..
Blackout condition me kya karna hai, Sudden trip of Boiler/Sudden trip of Tdbfp aise karke video bnaiye Sir
Sir what is lube oil accumlator????why it is needed?
Hp by pass to samjh aaya ki high pressure ko bypass kr rhe h, but lp by pass me 29 kg bataya to lp by pass kaise, ip tubine ke liye kitna pressure hona chahiye
Dead weight safely valve ....why?and how it works
Please make video my PA bearing broken very fast
MS line pressure bypass 150kg/cm2 ,CRH 30 kg/cm2 , HRH kaise Kam hoga ??
pressure loss due to steam travelling/friction
सर नमस्कार! Drum लेवल 1 , 50%और Drum लेवल 2 52% है और एवरेज लेवल 50%है अगर इनमें से किसी एक की वैल्यू दिखाई ना दे तब बॉयलर पर क्या इफेक्ट पड़ेगा कृपया मार्गदर्शन कीजिए प्लीज प्लीज प्लीज
Alternater bearing broken very fast make video for control
Interview ke update kaha se le
Sir BPE ka full form kya h
i wish i can find sort of content in english😢
What if HPbypass opens but not LP bypass?
Boiler Trips on Re-hetaer Protection
👍