Great sir g, में आपके सभी विडियो देखता हूं ओर इससे मुझे काफी जानकारी मिलती है , बहुत बहुत आभार ,आशा है आगे भी आप हमेशा एसे ही ज्ञानवर्धक विडियो बनाते रहेंगे
Sir, bahut badhia. But ekk doubt hai. Jab MP ko 0 sai N pai rakh thhai hai ammeter current nahi show karthha hai. But jab N+ lai thhain hai thho show karthha but as per diagram MP at N, line contactor pick up hai, thho current dikhana chahiye
MP ko N par rakhne se keval Line Contactor close hua hai ..na ki TFP charge hua hai...jab MP ko N+ par kakh ke notch lete hai to TFP charge hota hai aur TM me supply Jane se Ammeter show karta hai...
Sir, MP ko N pai rakhnai pai line cont pick hotti hai, but current load meter mai show nahi hotta as N ko + pai lene pai TFP charge hotta hai.isliye current show hotta hai.but inMU if MP N pai in leading rakh nai pai bhi trailing loco mai current kyun show hotta hai.as par guideline MP ko 0 par rakhna hai .pls explain
Nahi.. bilkul bhi nahi....but agar kisi ne kar Diya to ...for extra safety DJ ka NOI Diya hai ......Jisse ki Line Contactor DJ close hone ke baad apni closing conditions full fill hone ke baad hi close ho..
ऐसे भी गाड़ी मूव नहीं होगी क्योंकि प्राइमरी वाइंडिंग से म्युचुअल इंडक्शन एमपी 0 पर रहने के कारण नहीं होगा । तथा CGR 3 के माध्यम से करंट TFP के मेंनहीं पहुंचेगा.
Bohot achcha explain kiye sir.
बहुत अच्छा प्रयास 👌
Great sir g, में आपके सभी विडियो देखता हूं ओर इससे मुझे काफी जानकारी मिलती है , बहुत बहुत आभार ,आशा है आगे भी आप हमेशा एसे ही ज्ञानवर्धक विडियो बनाते रहेंगे
Thanks 😊
Excellent lecture sirjee, 🙏🙏🙏
bahut sahi sir ji❤
Thanks for excellent explanation
Very nice video sir, jai hind🙏🙏🙏🙏
Thank you sir ji
Exillant sir
❤ nice
❤
Sir, bahut badhia. But ekk doubt hai. Jab MP ko 0 sai N pai rakh thhai hai ammeter current nahi show karthha hai. But jab N+ lai thhain hai thho show karthha but as per diagram MP at N, line contactor pick up hai, thho current dikhana chahiye
Like our likes motivate u, ur reply creates interest to watch videos
MP ko N par rakhne se keval Line Contactor close hua hai ..na ki TFP charge hua hai...jab MP ko N+ par kakh ke notch lete hai to TFP charge hota hai aur TM me supply Jane se Ammeter show karta hai...
Sir, MP ko N pai rakhnai pai line cont pick hotti hai, but current load meter mai show nahi hotta as N ko + pai lene pai TFP charge hotta hai.isliye current show hotta hai.but inMU if MP N pai in leading rakh nai pai bhi trailing loco mai current kyun show hotta hai.as par guideline MP ko 0 par rakhna hai .pls explain
Sir vs3 kya hia
Diode hai
Agar GR kisi notch par atak gya to kya Q45 ka manual karke DJ close kar sakte hai
Nahi.. bilkul bhi nahi....but agar kisi ne kar Diya to ...for extra safety DJ ka NOI Diya hai ......Jisse ki Line Contactor DJ close hone ke baad apni closing conditions full fill hone ke baad hi close ho..
ऐसे भी गाड़ी मूव नहीं होगी क्योंकि प्राइमरी वाइंडिंग से म्युचुअल इंडक्शन एमपी 0 पर रहने के कारण नहीं होगा । तथा CGR 3 के माध्यम से करंट TFP के मेंनहीं पहुंचेगा.
Thank u sir ji