Bathroom Remodel Electrical Rough in | How much?

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ธ.ค. 2024

ความคิดเห็น • 13

  • @PhillyFixed
    @PhillyFixed 10 หลายเดือนก่อน +4

    Great vid as always, Steve! It's worth mentioning that, starting with the 2020 NEC, 406.9(C) requires receptacles to be at least 36" horizontally from the bathtub rim or shower base threshold. Receptacles for bidets or other toilet type accessories can fall within that 36" but have to be a *single* receptacle (not a duplex).
    If the bathroom is such that you cant achieve 36", then receptacles have to be on the wall opposite the tub/shower.
    In PA we're still on the 2017 NEC but many states have adopted either 2020 or 2023.

    • @tedmcdonald3377
      @tedmcdonald3377 10 หลายเดือนก่อน

      Look at the brains on Jim 😂🤣😂

  • @Shad0wC0mpany2
    @Shad0wC0mpany2 10 หลายเดือนก่อน +2

    Thank you for the upload!

  • @poli21
    @poli21 10 หลายเดือนก่อน +2

    A tip for the DIYers out there, if yr gonna do electrical, get yrself a pair of romex strippers and strip the wire before you put it in the box. Don't go in there hacking away with a knife. You will cut the wire.

  • @Sean-Aviation
    @Sean-Aviation 6 หลายเดือนก่อน

    cool! do you have a link to the fan timer used on this video?

  • @poli21
    @poli21 10 หลายเดือนก่อน

    48" top is standard, a lot of older homes are higher lol. Bathrooms 46" top. ADA asks for max 48" top or those who need to comply.

  • @johnmorrison1050
    @johnmorrison1050 10 หลายเดือนก่อน

    Hi Steve are you a licensed plumber and a licensed electrition?

    • @BathroomRemodelingTeacher
      @BathroomRemodelingTeacher  10 หลายเดือนก่อน

      Thanks for watching video. You’d have the answer if you did 👍

  • @ZachJoyce-g4j
    @ZachJoyce-g4j 10 หลายเดือนก่อน

    Just installed a clarion tub and caulked it with ge advanced white silicon and sprayed it with winder with vinegar. Now my silicone is yellowing everywhere the winded with vinegar was sprayed. Terrible tip. Please let your followers know to use something different.

    • @BathroomRemodelingTeacher
      @BathroomRemodelingTeacher  10 หลายเดือนก่อน +1

      Really? Sorry to hear that
      What the hell does this have to do with electrical? Did GE tell you this?

  • @tedmcdonald3377
    @tedmcdonald3377 10 หลายเดือนก่อน +1

    😎⚒️😎⚒️😎

    • @PhillyFixed
      @PhillyFixed 10 หลายเดือนก่อน +1

      Stop following me around, Ted! 😅

    • @tedmcdonald3377
      @tedmcdonald3377 10 หลายเดือนก่อน

      @@PhillyFixed 😂🤣😂🤣😂