Split air conditioner pipe icing problem (Section Pipe Ice) solve fault in Urdu/Hindi

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ส.ค. 2024
  • Split air conditioner pipe icing problem (Section Pipe Ice) solve fault in Urdu/Hindi
    How to solve AC fault easy
    How to trace Air conditioner fault
    For Sponsorship Email: Fully4world@gmail.com
    ------------------------------------------------------------------------------------------------------
    Subscribe: / fully4world
    Instagram Follow: / azamali256
    Facebook Page: / . .
    Azam ali FB ID: / smak.azam
    Website:: www.fully4worl...
    ------------------------------------------------------------------------------------------------------
    How to save Electricity bill बिल बचाओ,100% असली | 2019
    • How to save Electricit...
    Gas welding setup LPG,Oxygen cylinder Torch set Review and Function
    • Gas welding setup LPG,...
    All Gases Cylinder Important information
    • All Gases Cylinder Imp...
    Pressure gauge setting reading only 1 mint
    • Pressure gauge setting...
    Compressor pumping test with high pressure gage in urdu/hindi
    • Compressor pumping tes...
    How to clean refrigerator and fridge care tips in urdu/hindi
    • How to clean refrigera...
    Latest technology and RAC / HVAC related videos and information

ความคิดเห็น • 237

  • @learnsomething.601
    @learnsomething.601 3 ปีที่แล้ว +3

    Video ap bohat bari karty hen choti sahi h

  • @waseemahmed1470
    @waseemahmed1470 หลายเดือนก่อน +1

    زبردست

  • @shaikhaejazali4774
    @shaikhaejazali4774 26 วันที่ผ่านมา +1

    very good

  • @UsmanKhan-ff7ce
    @UsmanKhan-ff7ce 2 ปีที่แล้ว +1

    Both he achay azam bhai thanks

  • @safishaikh6737
    @safishaikh6737 4 ปีที่แล้ว

    Sir bahut accha video banaya he aapne

  • @gktech7751
    @gktech7751 5 ปีที่แล้ว

    just Awesome video sir Ak din Ap k jasa banany ka Dil karta hy bhai

  • @abdullahshah5427
    @abdullahshah5427 5 ปีที่แล้ว

    Thanks azam bro ap ka chenal very helpful hai 👍👍

    • @ArishKhan-xq3rf
      @ArishKhan-xq3rf 4 ปีที่แล้ว

      Allah paak aapko hamesha salamat rakkhe azam bhai aap ke wajah se bahot si cheez malumat ho jaati hai

  • @ShakeelAhmed-iw8zn
    @ShakeelAhmed-iw8zn 3 ปีที่แล้ว +1

    Waliqom Salam 🇵🇸🇹🇷🇵🇰🇧🇩❤️👍💯🤺✌️ labbaik ya rosol allah

  • @sallauddinshaik4524
    @sallauddinshaik4524 5 ปีที่แล้ว +1

    Thank you Bhai mera problem solved huva

  • @repairtech007
    @repairtech007 5 ปีที่แล้ว +2

    Good, nice information bro

  • @azajkhan5312
    @azajkhan5312 ปีที่แล้ว +1

    Nice Infarmesan

  • @lokeshnai7684
    @lokeshnai7684 5 ปีที่แล้ว

    Busy schedule me se time nikal ke hamare liye video banate ho thank you

  • @MohsinKhan-rt7xf
    @MohsinKhan-rt7xf 5 ปีที่แล้ว +1

    Sukriya sir

  • @sadikazmi630
    @sadikazmi630 3 ปีที่แล้ว +1

    Best job sir

  • @ahmadhusain4766
    @ahmadhusain4766 5 ปีที่แล้ว

    Azam bhai nice video

  • @shipmgr20
    @shipmgr20 3 ปีที่แล้ว +1

    Thank you sir

  • @eldoradofantasy7477
    @eldoradofantasy7477 ปีที่แล้ว +1

    Aazam bhai ager dono paipe par barf aa rhi h to kya problem ho skti h plz sir riplay me?

  • @NadeemKhan-jh8cf
    @NadeemKhan-jh8cf 5 ปีที่แล้ว +7

    Bro tell on inverter AC I have same problem in new ac which i had installed? 1ton Ac

  • @chetanchouhan7040
    @chetanchouhan7040 5 ปีที่แล้ว

    Sir j vari nice Info sir

  • @INDIAN-ys7fw
    @INDIAN-ys7fw 5 ปีที่แล้ว

    Nice video bhaii

  • @rajibahchen1490
    @rajibahchen1490 3 ปีที่แล้ว +1

    thanks

  • @waseemahmed1470
    @waseemahmed1470 2 หลายเดือนก่อน +2

    سپلٹ اسی میں گیس چارج کرتے وقت سیکشن پائپ لائن پر برف آرہی ہے کیا فالٹ ہے سر رپلائے کریں

    • @fully4world
      @fully4world  2 หลายเดือนก่อน

      pipe kahi sy bend ho skata hai

  • @IrfanKhan-jd8jg
    @IrfanKhan-jd8jg 4 ปีที่แล้ว +1

    Nice sir

  • @NoorMohammad-jb4rg
    @NoorMohammad-jb4rg 5 ปีที่แล้ว

    Nice video bhai

  • @SenthilKumar-xo9sn
    @SenthilKumar-xo9sn 3 ปีที่แล้ว +1

    Nicely Explained 👍

  • @mahiefatima5345
    @mahiefatima5345 4 ปีที่แล้ว

    Ustad Azaam Asslam Alikum is ac jo suction pe ice the is mein kya fauld tha please reply thanks

  • @tanvirhussian6885
    @tanvirhussian6885 5 ปีที่แล้ว

    Good

  • @nawabsharif8363
    @nawabsharif8363 5 ปีที่แล้ว

    Very nice

  • @food4thought.265
    @food4thought.265 5 ปีที่แล้ว +6

    110 % capillary choak issue

  • @asadmehar8918
    @asadmehar8918 5 ปีที่แล้ว

    tnx bhai

  • @alauddinanwerkhan7361
    @alauddinanwerkhan7361 4 ปีที่แล้ว +4

    Indoor chock
    Fan motor khrab
    Filtter and Bloor chock

  • @MerajAhmad-eo3gq
    @MerajAhmad-eo3gq 5 ปีที่แล้ว +1

    Aslamualaikum Azam Bhai sir ek window AC h usme bich wali pipe par ice arhi h keya problem ho Sakta h

  • @jharkhandrockstar7468
    @jharkhandrockstar7468 5 ปีที่แล้ว

    Thanks sir g 👌 👌 💗

  • @akashdeepkamboj9375
    @akashdeepkamboj9375 5 ปีที่แล้ว

    Good video sir

  • @chanchalsingh811
    @chanchalsingh811 2 ปีที่แล้ว +1

    Saks online discharge line donon per Aaye Sare yah kya problem hai

  • @sajidrehman8948
    @sajidrehman8948 4 ปีที่แล้ว

    Bhai inverter ac hy discharge pipe py starting m halki baraf aati hy oer kuch secend m khod khatM hojati hy as ka keya masala hosakta hy cooling b kam hy

  • @skK-xk3yc
    @skK-xk3yc 2 ปีที่แล้ว

    bhai technician ne discharge pipe ko 360 degree chota diameter bend kiya condenser connect karne se pahle ......kya ye sahi tarika hai cooling affect karega ?

  • @RasheedRD
    @RasheedRD 2 ปีที่แล้ว +1

    Bhai Dawlance ka LVS plus model he section pipe pe ice aati he or bar bar band b hota he indoor b bilkul saaf he blower b saaf he pipe min band b nhe he kia masla ho sakta he

  • @tecnicalguru3458
    @tecnicalguru3458 4 ปีที่แล้ว

    Agr Bhaijaan Capliray chock hai to Discharge line pr bhi ice Ayegi kya

  • @AnimationNetwork118
    @AnimationNetwork118 5 ปีที่แล้ว

    Bhai Hot & cold A.c. pr bhi video banana.

  • @merajalam7511
    @merajalam7511 4 ปีที่แล้ว

    Mene new ac liya hai but piche k unit se water gir rha hai wo v beech se jo ki pipe se jana chahiye tha
    1.5 ton ac lg split inverter ac
    Please respond

  • @mankirtsaab4483
    @mankirtsaab4483 4 ปีที่แล้ว

    thanks g

  • @shakiransari4296
    @shakiransari4296 5 ปีที่แล้ว

    Assalamualaikum bhai apse ek problem ka solution puchna tha L.G ka split ac h wo remote s off krne k bad apne ap phir start ho jata h bina remort k ese hi hota rhta h kbhi disply bhi gyb ho jaty h agr apko iska kuch solutions maloom h to please reply me

  • @saqibsaddique2572
    @saqibsaddique2572 5 ปีที่แล้ว

    Good information

  • @imrankhan-up1ih
    @imrankhan-up1ih 5 ปีที่แล้ว

    Thanks bhsi

  • @umarsiddiqui7445
    @umarsiddiqui7445 4 ปีที่แล้ว

    bhai compresser k pump khrb hta h jb sb kch thk ho to i hope you understand what did i say you

  • @appuafroz9371
    @appuafroz9371 5 ปีที่แล้ว +1

    inverter ac ka outdoor unit ke pcb me compressor or fan ka capacitor hai Kya brother

    • @mahfozalam9822
      @mahfozalam9822 5 ปีที่แล้ว +1

      ha ji dona h but fan capacitor alag h

  • @binodkumarram8568
    @binodkumarram8568 5 ปีที่แล้ว

    Nice video

  • @ibrahimbhai885
    @ibrahimbhai885 5 ปีที่แล้ว

    Azam bhai inverter model ka system par video banaeye

  • @mohdayaz6127
    @mohdayaz6127 5 ปีที่แล้ว

    Nice vedio

  • @skjeelu6484
    @skjeelu6484 5 ปีที่แล้ว

    Iske Karan ac rhuk jata Kya phirbi Jara deri baad on hota Kya plz tell me

  • @Climatecoolpoint
    @Climatecoolpoint 4 ปีที่แล้ว

    Bhai ise suction ka line bolte hai ya section reply please

  • @NajimKhan-yh2wp
    @NajimKhan-yh2wp 4 ปีที่แล้ว

    Outdoor unit ke donon wall band kar de to kya problem ho sakti hai

  • @user-sh7lm8yk6j
    @user-sh7lm8yk6j 5 ปีที่แล้ว

    Nice video but mene apko 5 ton ac ka wearing batay kiu nahi plz vai mene. Rela or kontra er cunektion batau vai

  • @TheZubairgani
    @TheZubairgani 5 ปีที่แล้ว +3

    Assalamualekum

  • @newpromovideo4867
    @newpromovideo4867 5 ปีที่แล้ว +3

    ac outdoor condenser leak hota h k ni ?

  • @sulamanimran8482
    @sulamanimran8482 5 ปีที่แล้ว

    Mera outdoor unti me ice problem a rahi hai mein gas bhi charge ki hai prasure 60psi rakh hai outdoor unit ki service bhi krli hai phr bhi patle walye pipe pa ice halki halki aa rhi hai mgr cooling thek kr rha hai me caplri tupe konsi hoti hai me us ko bhi check krlo

  • @shaikhzubair9602
    @shaikhzubair9602 4 ปีที่แล้ว +1

    Fan motor ki speed Kam ya zyada ho Jaye tab bhi ye problem aata hau

  • @muhammadwajid9515
    @muhammadwajid9515 4 ปีที่แล้ว

    Sir section line pa ice ha not working cooling line ke length bhe normal ha 10 fit then phr bhe ice ha section line pa or cooling nai ho rahy

  • @mohammadyasirkhan8890
    @mohammadyasirkhan8890 5 ปีที่แล้ว

    Assalamu Alaikum Azam bhai plz ek pcb kit wiring batao jisme relay nhi hoti balik usme sirf ek wire hota hai usko kaise trace aur pata ki output ki wire hai ...plz Azam Aap bhai batao

    • @gktech7751
      @gktech7751 5 ปีที่แล้ว

      wo Cp wire huti hy bhai wihte color ma

  • @sohailmaher3690
    @sohailmaher3690 5 ปีที่แล้ว

    Maa shaa Allah......9c

  • @bhanusingh1200
    @bhanusingh1200 2 ปีที่แล้ว +1

    Suction discharge pipe me curent aaye to Kya kre

    • @fully4world
      @fully4world  2 ปีที่แล้ว

      Compressor shortage ho ga

  • @hummahumma276
    @hummahumma276 3 ปีที่แล้ว

    useful

  • @yogitech3524
    @yogitech3524 4 ปีที่แล้ว

    hlo aajam bhai main avi Godrej ki new AC install Kiye Hain Jiske donon per hi ice jam Rahi Hai To Hum Kya Karen bataen?.. balki ye problem ak Main Nahin balki 3 4 AC Mein a rahi to aap btye hum kya kare.. pipe bhi only 25 se 30 fit h.... hume btye hum kya kre...

  • @yadavairconditioner6141
    @yadavairconditioner6141 2 ปีที่แล้ว

    Sir split AC mein Section line aur discharge line mein insulation kyo Laga hota hai lagne ka mtlab kya hai

  • @AlamKhan-vq6pg
    @AlamKhan-vq6pg 3 ปีที่แล้ว +1

    Maphlar me ice ane ka kya problem hai

  • @mshasnain8639
    @mshasnain8639 5 ปีที่แล้ว +1

    السلام علیکم آجم بھائی

  • @mudassarakbarali6511
    @mudassarakbarali6511 4 ปีที่แล้ว

    Sir ap پاکستان main kis jaga se ho

  • @karamrehman3659
    @karamrehman3659 5 ปีที่แล้ว

    Bhai g indoor unit ko utar Kar ap hamein service karna seekhayein usy kholna else or fit kese kre

  • @pravinvakatarctm7534
    @pravinvakatarctm7534 4 ปีที่แล้ว

    O general AC error check and repair

  • @shaikhzubair9602
    @shaikhzubair9602 4 ปีที่แล้ว

    Filter bhi clean hai aur condensir coil bhi ...
    Ye problem gais jayada ho Gaya fill up karte time to ye problem aati ..

  • @gmmaqsood117
    @gmmaqsood117 5 ปีที่แล้ว +1

    Aray brother indor fan motor speed check karo

  • @azhar.ma54
    @azhar.ma54 5 ปีที่แล้ว

    As Salamalaikum bhai compressor accumulator pe ice hai aur return psi 130 hai plz bole kya prblm hai

  • @pratibhasingh3764
    @pratibhasingh3764 5 ปีที่แล้ว

    Suction pipe or discharge pipe par pani aana normal hai

  • @SaadAli-mw8co
    @SaadAli-mw8co 4 ปีที่แล้ว

    AC ka chota pipe ka Safed Hona kya kharabi hai usmein

  • @sukhwindersingh-dw9gr
    @sukhwindersingh-dw9gr 4 ปีที่แล้ว

    hmare ac me gas full charge hai but section pipe thanda kam ho raha hai please is ke bare mai bataye mujhe

  • @alighafoor2344
    @alighafoor2344 4 ปีที่แล้ว

    Mera ac ma icing nahi ha lakin pani ha please es ka k jawab dein

  • @wajidrajputofficial
    @wajidrajputofficial 5 ปีที่แล้ว

    Nice

  • @mohansingh6063
    @mohansingh6063 4 ปีที่แล้ว

    sir blur star ka 1.5 ac haa oss main ketne number capliry tube lageane

  • @mdsarfarazalam9324
    @mdsarfarazalam9324 5 ปีที่แล้ว

    Chhota pipe lining dene se kya Kuchh problem bhi hota hai

  • @bharat22231
    @bharat22231 5 ปีที่แล้ว +1

    1 outdoor de 2 indoor kaise chalayen

  • @abuusmanali3855
    @abuusmanali3855 5 ปีที่แล้ว +2

    is m Capri k flat ni ho sakta

  • @ramzanpathania5821
    @ramzanpathania5821 4 ปีที่แล้ว

    Dono pr ice aae tw kia problem hai??

  • @sangeetakumarivaishnav4927
    @sangeetakumarivaishnav4927 5 ปีที่แล้ว

    Coman ka terminal ka thimabal bar bar male ka Karan

  • @aazadansari2683
    @aazadansari2683 5 ปีที่แล้ว

    Sir rotry compressor and recy compressor ka ragistans kitna hona chahiye

  • @shaikhzubair9602
    @shaikhzubair9602 4 ปีที่แล้ว

    R22 gais hai sir .. capliry 64 aur 70 ke raheti wo kabhi chock nahi hoti ..ac kabhi chock nahi hota

  • @bhuraturki9868
    @bhuraturki9868 3 ปีที่แล้ว

    Bhai mene ek ac repair kya h.. Section pr ice aa rahi thi indoor SAF kya pr gas bhi Kam thi 😇😇😇🙆‍♂️🙆‍♂️🙆‍♂️gas charging krne pr sahi ho Gaya

  • @m.nouman14
    @m.nouman14 3 ปีที่แล้ว

    Oh bhai jab ac chalta ha to suction wall se baraf ander ki taraf jati ha ye fault batao

  • @waseemahmed1470
    @waseemahmed1470 2 หลายเดือนก่อน +1

    R22 میں

  • @mokshkunjam3489
    @mokshkunjam3489 5 ปีที่แล้ว

    Ac band h to aur uska gas chek krte to pressure sahi bta rha h lekin chalu karte hi uska pressure kam ho jata h... kya plm ho sakta h ...

  • @NajimKhan-yh2wp
    @NajimKhan-yh2wp 4 ปีที่แล้ว

    Inverter AC hai gas bhi hai usmein

  • @roshandilip8009
    @roshandilip8009 5 ปีที่แล้ว

    Evoparetor pe sirf ek side cool horahai dusri tharaf cooling nahi horahahai , or discharge and sucktion line pressor sahi hai ese kiu hoatha hai

  • @anishburhan4301
    @anishburhan4301 4 ปีที่แล้ว

    Bro plz tell me 15 minit after Compressor het and off

  • @Riyaz__76
    @Riyaz__76 4 ปีที่แล้ว

    Allah hafiz bhai

  • @poornimaverma1513
    @poornimaverma1513 5 ปีที่แล้ว

    gas leakage hai bar bar outdoor exzorze band ho jata hai jiski vajah se cooling nhi ho Rahi btaeye Kya kare Abhi check bhi Karaya tha or gas bhi bharai thi 2 hafte pehle

    • @gameguru6103
      @gameguru6103 2 ปีที่แล้ว

      Bhai pipe line check kro puri aap k ghar k aas pass agr nala h to 100% problem aati h

  • @VikasThakur-ow1er
    @VikasThakur-ow1er 3 ปีที่แล้ว +1

    Section line me ice aa rhi he or indoor bilkul clean he, indoor fan motor speed bhi theek hai, pipe me bend bhi nhi hai, tou iss kase me kya krre

    • @fully4world
      @fully4world  3 ปีที่แล้ว +1

      Pipe bend to nhi khi sy ye dekho

    • @VikasThakur-ow1er
      @VikasThakur-ow1er 3 ปีที่แล้ว

      @@fully4world back pressure 60 Aa rha he

    • @VikasThakur-ow1er
      @VikasThakur-ow1er 3 ปีที่แล้ว

      iss liye bend tou ho nhi sakte

  • @yasirmustafawalana7004
    @yasirmustafawalana7004 5 ปีที่แล้ว +1

    Bhai agar dono pieps par ice ay to kea foult and ha

  • @arshadkhan-iz3vu
    @arshadkhan-iz3vu 5 ปีที่แล้ว +2

    Sir koi esa video banao jisme remote match karne ki trick ho matalb remote koi aur company ka aur ac kisi aur humko pcb repair bale se karbani padti hai to samajh nahi aata hai wo kaise match kar deta hai

  • @dipakmaheshri3505
    @dipakmaheshri3505 5 ปีที่แล้ว

    आजम भाई सलाम,मेरा सवाल हे की मेरा LG 1.5 टन के इन्वर्टर AC मे कुलिंग कम आ रही है,आउटडोअर यूनिट कट नही होता,क्युकी अंदर सेट डिग्री तक कुलिंग नही आ पाती हे ,वारन्टी पीरियड मे है,पर सर्विस सेंटर वालो को फौल्ट नही मिल रहा हे,मेने आपाके यू टयूब च्यनल लिंक को उनको भी सबस्राईब किया हे,प्लिज आप ईस कमेंट का जबाब देकर LG सर्विस सेंटर (वसीम,उमर,एव अनिस) भाई की मदत करे,उनका आपको चलेन्ज है कि आप ये सॉल्व नही कर पाओगे,इनडोर तथा आउटडोअर यूनिट साफ हो चुके हे पर वो स्टडींग एव रनीग गैस R410a चेक नही कर रहे हे,इनडोर यूनिट से पानी भी बाहर नही गिरता,जबकी लाईन खुली हे,कृपया उनके चलेन्ज का जबाब दे,मेरे AC,रेफ्रीजरेटर ट्रेनिंग गुरु,अल्ला हफिज

    • @mshasnain8639
      @mshasnain8639 5 ปีที่แล้ว +1

      Unka sensor change kar dijiye

  • @laxmiacharya1321
    @laxmiacharya1321 4 ปีที่แล้ว

    Suction (copper) pipe k yahan se water leakage ho toh kya problem hoti h