  • 316 Stainless, or SA 240 API 653 internal inspection. Tank have just over two years of service at the time of being removed from service and the inspection. Corrosion with pitting of 15 to 40 mils (0.040") deep.

ความคิดเห็น • 13

  • @jparrales86
    @jparrales86 2 ปีที่แล้ว +1

    Very nice video, very interesting to see this type of corrosion on stainless. Similarly I've seen brand new stainless floors with MIC corrosion all throughout the HAZ of the floor plates. Come to find out the tank had about 8 feet fire water just sitting stagnant in there for 3 months which resulted in the MIC corrosion. Please keep these videos coming 👍

    • @MrEric_API
      @MrEric_API  2 ปีที่แล้ว +1

      Thanks, glad you liked the video. Mr.Eric

  • @okaguacharles2943
    @okaguacharles2943 3 ปีที่แล้ว +1

    Nice to see this.

    • @MrEric_API
      @MrEric_API  2 ปีที่แล้ว

      Glad you enjoyed it. More like this to come.

  • @mclarenmclaren2010
    @mclarenmclaren2010 2 ปีที่แล้ว +1

    Wow. Just imagine the cost to build this tank. To find out it’s being corroded in such a small time frame And then having it removed. It’s Pennie’s to the process plant but still though. Money down the drain. Which sucks because I know welders took pride in building such a large tank. We’ll hopefully they did.

    • @MrEric_API
      @MrEric_API  2 ปีที่แล้ว +1

      Glad you liked the video, it's an unusual example that I thought people would like to observe.
      Yes. The cost of this AST was in the millions of dollars when it was built just a few short years ago.
      This is a classic example of several things, spending money on the wrong thing is the greatest point, and not spending money on other portions of the project is another.
      MrEric

    • @scottieb6442
      @scottieb6442 ปีที่แล้ว

      Our last 3 million gallon field install was hidden from my office but you could definitely hear it!

  • @raserbacal7098
    @raserbacal7098 3 ปีที่แล้ว +1

    Interested to find out what was the repair recommendation before putting the tank back in service?

    • @MrEric_API
      @MrEric_API  3 ปีที่แล้ว +2

      The client had committed to removing from service in two years.

  • @imchris5000
    @imchris5000 3 ปีที่แล้ว +1

    I wonder if they used the wrong filler metal when welding the tank

    • @MrEric_API
      @MrEric_API  2 ปีที่แล้ว +1

      Chris, I dont think so. I am scheduled to inspect this AST again next year. I have recommended that I have a PMI unit to be able to test the welds and HAZ while I perform internals on the next couple of ASTs.

  • @imchris5000
    @imchris5000 3 ปีที่แล้ว +1

    sludge build up maybe means theres a water leak

    • @MrEric_API
      @MrEric_API  3 ปีที่แล้ว +1

      Lots of floculent in the water, they are chemically treating to get it to settle out.