Contactor me mostly two problem hote hai ek contactor hold na karna second problem contactor thik se input aur output point contact apas me na cotact ho pana .aisa problem jaydatar kisi ek phase me hi hota hai but kisi khas situation me hi tino point contact nahi ho pata hai to ham ise bypass kar dete hai .ye problem jaydatar low voltage ki wajhon se hoti hai bar bar cotntact hold karna chhorne ki wajah se load k karN spark create hota jisse contactor jal jata ya kharab ho jata hai .side ko minimum 180 v tak operate kar sakte hai isse kam hone pe contator ko jalna rectifier kharab hona etc problem ho sakti hai.
Bahut achhe se samjhaye sir
आदरणीय सर जी एक वीडियो SMPS मे लगने वाली सभी कार्ड एवम उनकी वर्किंग के बारे मे बनाने की कृपा करे जी
Good very shot solution
Delta sps ka videos b bna dijiye sir🙏
Great video 👍👍
Bhut achchhe
Sir HPS ka pin configaration bare me eak video dijiye
Hello ...me atc me hun ...odisha atc se...amararaja battery delta 4000 SMPS se garam kyu ho rahare ..savi cell
Ok SMPS ki charging setting check karo
Ap sabhi ko float voltage , boost votage and battery ah chek kare smps me kitna pe setting kiya hua hai
भाई जी आप से बात करना था कुछ जानकारी लेना hain नंबर देंगे @@TelecomKnowledge1989
Sir ya jo lvd hai konse type ke hai.. No,Nc,luch ??
Ryt sir
Nice
Nice videos by you......
Dada Mera ek site main view B lvb Kam nahi karrahai key karu Thora boliye delta 4000
Lvd change video daliye
But controlar kharab hene k bad Blvd kase kam karega
Psc3 configuration awaited fault a rha hai sir kya karein?
How we know lvd is faulty not lvd card
great
Thanks
Sir app autometion ki full settings and calibration pe video banao
Mains available all 3 phase available but mains contractor not working by doing bypass it's working where to check please make a video
Contactor me mostly two problem hote hai ek contactor hold na karna second problem contactor thik se input aur output point contact apas me na cotact ho pana .aisa problem jaydatar kisi ek phase me hi hota hai but kisi khas situation me hi tino point contact nahi ho pata hai to ham ise bypass kar dete hai .ye problem jaydatar low voltage ki wajhon se hoti hai bar bar cotntact hold karna chhorne ki wajah se load k karN spark create hota jisse contactor jal jata ya kharab ho jata hai .side ko minimum 180 v tak operate kar sakte hai isse kam hone pe contator ko jalna rectifier kharab hona etc problem ho sakti hai.
Hi
Kindly send delta dcem password
Sir apka number degey
Galat bol raha hai
Pls Provide number boss
Nice