WHY Chilled Water Pipe Pressure Test failed? क्यों ठंडा पानी पाइप दबाव परीक्षण विफल रहा MEP Tech Tip

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 ต.ค. 2024
  • In this video, We will try to find out why the chilled water pipe pressure test failed.
    Am waiting for your comments on this video what is the reason behind this failure.
    We need your support to continue our journey
    For other related videos please check the below links
    How to Install fire fighting sprinkler system in Hindi! फायर स्प्रिंकलर सिस्टम कैसे स्थापित करें - Part-1
    www.youtube.co....
    How to Install the Fan Coil Unit (FCU)
    www.youtube.co....
    How to install fire rated Ductwork in basement | Smoke Control ductwork
    www.youtube.co....
    Fire Damper Installation or How to install a Fire Damper
    www.youtube.co....
    Fire Fighting Red paintwork Step by Step
    www.youtube.co....
    Join or follow us on Social Media
    Twitter:- @Mohamme52311467
    FaceBook:- @MEPtechtipsforyou
    Instagram:- meptechtips
    Whats Group link:- chat.whatsapp.....
    Thanks for watching
    MEP Tech Tips
    MEPTECHTIPS
    Be sure to click the 👍 button and subscribe for more content!

ความคิดเห็น • 33

  • @mirzaumarBaig
    @mirzaumarBaig 5 ปีที่แล้ว +7

    there is a lot of air in your lines... please perform venting in your system b4 starting your test.

  • @mohdmehfooz72
    @mohdmehfooz72 2 ปีที่แล้ว

    Or Kitna tr Ka unit connect Ker sakte h please give me reply plz

  • @SaddamHussain-hn1ny
    @SaddamHussain-hn1ny ปีที่แล้ว

    FCU ka in aur aut upar hota hai ya nice bataye

  • @mohdmehfooz72
    @mohdmehfooz72 2 ปีที่แล้ว

    Sir ek office area me ek chiller pipe as raha h usme kese pata lagaye ke us chiller pipe se Kitna unit connect Ker sakte h

  • @GovindPatel-nj5bc
    @GovindPatel-nj5bc 3 ปีที่แล้ว

    Heme bataiye presser testing me kya kya lagata hai interview me pucha Jaya hai

  • @asrar121
    @asrar121 3 ปีที่แล้ว +1

    Kiyu me ajkal fire and chillerd ka testing kara rha hun mujhe is ka acche se idia he second time pump karne se ruk jata hai or bahtar he ke ham hamd pump us kar nake nashin

  • @asifhussainasifhussain6455
    @asifhussainasifhussain6455 4 ปีที่แล้ว

    Sir ji pump selection kesy karty h bataye furmula

  • @asrar121
    @asrar121 3 ปีที่แล้ว +1

    I ting in side hawa ka problem hai

  • @qumartanweer6589
    @qumartanweer6589 ปีที่แล้ว

    Why we need to remove air from Pipe and how can i remove air in pipe

  • @shaikhjafar3817
    @shaikhjafar3817 11 หลายเดือนก่อน

    Becoz of air

  • @nandansingh2037
    @nandansingh2037 3 ปีที่แล้ว

    how to pressure drop to leak test ratio to

  • @muhammedali8787
    @muhammedali8787 4 ปีที่แล้ว

    Thanks for the detailed video... Keep it up. 👍👍

    • @MEPTECHTIPS
      @MEPTECHTIPS  4 ปีที่แล้ว

      Thanks and Your welcome

  • @ZeeshanKhan-fg7ry
    @ZeeshanKhan-fg7ry 5 ปีที่แล้ว +1

    Supply and return pressure aur temp kitna hona chahiye???
    Pipe size ke hisab se operating pressure kitna hona chahiye??

    • @MEPTECHTIPS
      @MEPTECHTIPS  5 ปีที่แล้ว

      Brother Zeehsan, While ur doing pressure test for chw pipe is depend upon ur system design basically
      And Temperature nothing to do in Chw Pipe pressure test because ur checking and observing leakage in ur pipeline for a certain time

    • @ZeeshanKhan-fg7ry
      @ZeeshanKhan-fg7ry 5 ปีที่แล้ว

      @@MEPTECHTIPS suppose u r doing test for 50 mm chw line ..how much pressure requaired for testing...it means reading of tested pressure. What are the normal /avg values of chws and chwr line that can bear ??

    • @MEPTECHTIPS
      @MEPTECHTIPS  5 ปีที่แล้ว

      Brother Zeshan,1. Any size of pipe not only 50mm less then this exm: 20mm also u have to do pressure test as per system design for the respective project, Again its also depend upon sch of pipe which ur using at site for exm: if u have sch-40 pipe its has some certain limit lets say 20bar, if u have sch-80 it has more strength then sch-40.

  • @sajeebsheikh2806
    @sajeebsheikh2806 3 ปีที่แล้ว

    Where can I get this machine? How much does it cost?

    • @MEPTECHTIPS
      @MEPTECHTIPS  3 ปีที่แล้ว

      Just chk on google you will get it on your local area

  • @abdulsattar-zg8hw
    @abdulsattar-zg8hw 3 ปีที่แล้ว

    Automatic Air vent is not provided. Pressure will increase where the pipe is exposed without insulation, here pipe is not exposed hence issue of Air vent.

  • @mohdhashim7129
    @mohdhashim7129 5 ปีที่แล้ว

    Reason samjh nhi aya ye .. plz tell jow pressure goes up frm 12 to 17 bar

  • @engineersingulf6968
    @engineersingulf6968 5 ปีที่แล้ว

    Why pressure goes high???

    • @MEPTECHTIPS
      @MEPTECHTIPS  5 ปีที่แล้ว

      The answer in this video link th-cam.com/video/ySldsYAl_Os/w-d-xo.html

  • @mansoorimohammad4595
    @mansoorimohammad4595 4 ปีที่แล้ว

    May be the main reason of increasing pressure is secondary pump .....