Earth Clamp Tester UNI-T (UT275+)

แชร์
ฝัง
  • เผยแพร่เมื่อ 18 ต.ค. 2024

ความคิดเห็น • 21

  • @naturetruth5218
    @naturetruth5218 ปีที่แล้ว +1

    So all grounding failed? Sure can measure single grounding point without connecting two ground points to measure the resistance different between two?

    • @hazzizulghani90
      @hazzizulghani90  ปีที่แล้ว

      This is the temporary microwave and radio tower for emergency uses only and the grounding connection is used Multiple Ground Electrodes Connected. The reading value resistance measured between that electrode using Earth Clamp Tester is not a true ground resistance measurement because of the network ground. this is mainly a continuity test to verify that the site is grounded that we have an electrical connection and that the system can pass current. The Fall - of - Potential test method must be used to get the actual resistance value.

  • @nz9552
    @nz9552 2 ปีที่แล้ว +1

    Single point boleh amik reading tak bos?

    • @hazzizulghani90
      @hazzizulghani90  2 ปีที่แล้ว +1

      Boleh dengan syarat kena buat satu jumper sementara untuk rod buat selari dari tanah..

    • @nz9552
      @nz9552 ปีที่แล้ว +2

      @@hazzizulghani90 boleh buat video lebih detail pengunaan clamp ni boss, sebab ada beli tp tak faham kaedah pengunaan, model 278A.

    • @hazzizulghani90
      @hazzizulghani90  ปีที่แล้ว +1

      @@nz9552 Baik Insyallah tuan saya akan cuba buat nanti ok… Terima Kasih…

    • @nz9552
      @nz9552 ปีที่แล้ว +2

      @@hazzizulghani90 terbaikkk tuan alhamdulillah terima kasih👍👍

    • @atehwiringW.N.W
      @atehwiringW.N.W ปีที่แล้ว +1

      Sy pun nk bljr

  • @zaidinashima1984
    @zaidinashima1984 2 ปีที่แล้ว +2

    Ok kh x ohm ya u?

    • @hazzizulghani90
      @hazzizulghani90  2 ปีที่แล้ว

      Blom brani madah ok or sik u… sebab tester mesin masih dlm kitaran percubaan… 😅

  • @abangpianokey5227
    @abangpianokey5227 ปีที่แล้ว +2

    O.L not over limit but it short from words open load.

    • @hazzizulghani90
      @hazzizulghani90  ปีที่แล้ว +1

      Yes, thank you sir…👌😁

    • @shikinkassim1030
      @shikinkassim1030 ปีที่แล้ว +3

      Technically "Over Limit" is also correct, its means over than the limit range from testing value. Generally O.L stand for Open Loop if in resistance measurement, Over Loaded if you test capacitance and Over Limit If in voltage measurement.

  • @saimizirajak121
    @saimizirajak121 2 ปีที่แล้ว +1

    Meter ya ada x besi pake calibrate/ pake test nya?

  • @nasrieli7653
    @nasrieli7653 2 ปีที่แล้ว +2

    mok pake brand fluke juak kali..hehe

  • @dchungmanson
    @dchungmanson ปีที่แล้ว +1

    misleading

    • @hazzizulghani90
      @hazzizulghani90  ปีที่แล้ว

      Yup.. so many Open Loop at this telco tower… this is standby telco only..