Back At That HIU, Did I Fix It This Time? - A Day In The Life Of A Gas Engineer 177

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ม.ค. 2025

ความคิดเห็น • 31

  • @cputilitysolutions
    @cputilitysolutions  4 หลายเดือนก่อน +2

    What do you think of the first person view on this one? I'm starting to do more like this so I hope you enjoy it! Please don't forget to LIKE & SUBSCRIBE 🙏🏾

  • @bluebulldog_uk
    @bluebulldog_uk 4 หลายเดือนก่อน

    The Main boiler brings back some memories…at BG we would replace everything, seals, burner, gaskets, flue seals…even the air box if they was under contract 😢😅. On The HIU mate I could feel your disappointment! Hopefully get to the bottom of it 👊👍

  • @happybunny7490
    @happybunny7490 4 หลายเดือนก่อน +2

    That leaking inside the boiler is a heat exchanger leaking wet side not the dry ( Co ) side , very common on those boilers mate , also boiler could have been kept on as plenty have historic signs on leakage but stop on there own . But the boiler needed replacing anyway.

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +1

      @@happybunny7490 gotcha mate appreciate the advice 👊🏾

    • @joncoke8208
      @joncoke8208 4 หลายเดือนก่อน +1

      Theres also a way to check flue integrity on that boiler too

  • @russellbaldry5095
    @russellbaldry5095 4 หลายเดือนก่อน +1

    I dropped my 3 to primary school everyday and it means a lot to your kids to not put them before work 👍🏼👊🏼 was a bit tricky getting 3 on the 2 seat passenger side and wrap the seat belt over🤦🏼‍♂️😂

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +2

      I can imagine mate, defo won't get these times back 🙏🏾

  • @colin4685
    @colin4685 4 หลายเดือนก่อน +1

    Good old potterton SL. Burner tray cracked and melted a hole in the back? 😂

  • @mattygeepph4115
    @mattygeepph4115 4 หลายเดือนก่อน +1

    Hi bud top work as always had this on and it turned to be the pressure differential valve there's a diaphragm that fails inside it 👍 😊

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +1

      Thanks mate, is that the PM valve you're referring to?

    • @mattygeepph4115
      @mattygeepph4115 4 หลายเดือนก่อน

      Yes mate it's the proportional flow controller is it made by melbiec or oventrop bud 😉 👍😎👍😎👍😎👍😎👍

  • @joncoke8208
    @joncoke8208 4 หลายเดือนก่อน +1

    Looking jacked in the vest mate

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +1

      @@joncoke8208 haha cheers mate, was pumped from the hot weather! 😄

  • @stovesellers
    @stovesellers 4 หลายเดือนก่อน +2

    FPV worked well on this one. Everything in view. As for the video it's another cliffhanger!

  • @seanmcgee5060
    @seanmcgee5060 4 หลายเดือนก่อน +1

    It's gotta be a simple blockage somewhere, surely.... 🤔

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +1

      Definitely contained within the unit, just need to pinpoint it

  • @b1h2u3p4
    @b1h2u3p4 4 หลายเดือนก่อน +1

    What was wrong with the first boiler in the video was it the heat exchanger leaking

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +2

      Yeah mate and POCs spilling out the back

  • @Heatking
    @Heatking 4 หลายเดือนก่อน +1

    Feel for you on that HIU mate :(

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +2

      Lucky the customer was very understanding and could see I was trying to eliminate things step by step

  • @cliveramsbotty6077
    @cliveramsbotty6077 4 หลายเดือนก่อน +1

    get your commercial ticket mate you've got the brain for it

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +1

      Thanks mate, been told to do it by a few others too!

  • @TARSoda
    @TARSoda 4 หลายเดือนก่อน +1

    Know it may sound like I'm trying to teach you how to suck eggs here but have you ruled out the iso valve? Had a few fail on Elson HIU's, which made me feel a right tit after I'd already changed a couple parts.

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +2

      Not at all mate, sometimes it's the simplest things that catch us out. So the reason I know it's something within the unit itself is because when I turn that blending valve to all the way cold, the water pressure comes out perfect, but as soon as I wind it back to hot the pressure diminishes. That's why I thought it might be the blending valve, but it's gotta be that PM valve now. There's nothing else left between the cold in and hot outlet 🤔

    • @TARSoda
      @TARSoda 4 หลายเดือนก่อน +1

      @@cputilitysolutions Is there a strainer valve on this HIU? And if so have you cleaned it out? Know they can wreak havoc on both flow and temperature in combi HIU's lad. Some days you wonder you ended up in such an easy job and others you're up at night in cold sweats 😂

    • @cputilitysolutions
      @cputilitysolutions  4 หลายเดือนก่อน +2

      @@TARSoda there wasn't a strainer on the domestic circuit on this one, only on the primaries. But yeah it was getting to that point, but luckily the customer was on my side and he said he only wants me to deal with it so that took the pressure off a bit