Bon sr thanks your are gem sr we know how useful your vedeos.. Sr if you visit india 🇮🇳pls meet us lot of my aircon friends and special me i want to meet you.. Lot's of love from 🇮🇳
Hello Thx for sharing ,please i got high pressure sensor on VRV2 R407 a ,faulty and cant find the part as it old ,is there any idea for retroffit or like puting something else instead. Many thx
hi bon i like ur videos very much... i want to know in daikin vrv-x how many eev are there ...is there 2 eev in vrv 1 in outdoor 2nd in indoor plz help...& plz gude me the suction pressure of vrv- r-410 what is the ideal suction pressure in full load thank u sir...
Hi sir I have a doubt sir DAIKIN ducted unit drain pump open but incoming fcu power have not turn off pump still running rights that time water reverse back what is the cause of problem drain pump or drain pipe
Bon sir is an indoor which is master wired remote is not getting any error in it and its fan motor is not running and running without direct pcb then have ordered new pcb yet same problem is coming plz help sir
Even after installing a new PCB, the same problem is coming, if you run the fan motor without a PCB, then it is running fine and this problem is coming only in the master indoor, reset the outside door and has also done test mode
@@cantran5730 Normally VRV4 one of the indoor faulty or miss communication, you try to reset(push the return button more than 10 second)and wait untill the led off.
sir bon swiching from phillipines thank you for shar your skill ..
Welcome!
I enjoyed very much this clip. Short and to the point. Exactly what i need. Thank you.
Welcome
GOD bless Mr. Bon. From philippens thank you for sharing knowledge.
Welcome bro
Very experienced technician.
Thanks
Bon sir we are eagerly waiting for your video the way you explain it is very good thank you very much
Welcome 🙏
Sir good you teaching ❤and your video very useful help teaction vrv good 💯 information
👍👍
Thank you 🙏 for sharing AC knowledge Mr.Bon MJ
Welcome
Sir...your all videos easily learn Aircon
Thanks
الله بنور على يا هندسه على الفن الجميل يا ليت كل الفيديوهات مترجمه لغه العربيه
Bon sr thanks your are gem sr we know how useful your vedeos.. Sr if you visit india 🇮🇳pls meet us lot of my aircon friends and special me i want to meet you.. Lot's of love from 🇮🇳
Thanks bro🙏🙏
Thanks sir, I am from india
Welcome. Thanks 🙏
Good teaching 谢谢bon
谢谢你。
Good job.. today you had a hard job without your team...
Yes.Thanks 🙏🙏
Thank you sir for this informative video❤
Welcome 🙏
Thank you sir helpful your video 😍🙏
Welcome 🙏🙏
tq mr bon ,
Welcome 🙏
So did you say the body needs to be replaced as well when there is an issue? I assume you can braze in a new one?
Thanks for useful video.
Welcome
Thank for sharing your experience bon, i also want to join your team how to join
thanks sir Bon
👍
Terbaik Boss.ku
Terima Kasih🙏
More videos master bon God bless 🙏
Thanks bro
Thnxx 👌💕
Welcome
Thanks
Welcome
Thank you sir
Welcome 🙏
Boss how to check cu fan motor reading and fcu fan motor reading for Daikin type
very good
Thanks
Hello Thx for sharing ,please i got high pressure sensor on VRV2 R407 a ,faulty and cant find the part as it old ,is there any idea for retroffit or like puting something else instead.
Many thx
Vrv 2 R 407c
Vrv2 407c
good day mr bon ,if mr bon has free time, there is a video about troubleshooting floor standing 5 hp, you can share it, thanks mr bon
Hi sir
Thanks for your update the video sir
I have one doubt sir ,why could not check gas liquid side one to one system. May i know sir
I got check actually,but not in the video.
@@BonMj this one need to check or not sir
@@peramaraj2763 better check.
High pressure service port is on top.
@@BonMj i check gas liquid side sir but gas lower than suction side
@@peramaraj2763 may insufficient gas
hi bon i like ur videos very much... i want to know in daikin vrv-x how many eev are there ...is there 2 eev in vrv 1 in outdoor 2nd in indoor plz help...& plz gude me the suction pressure of vrv- r-410 what is the ideal suction pressure in full load thank u sir...
New VRV-X got 3 EEV(main,injection and auto charge)
Every indoor got 1 EEV
Pressure depending on the system
i highly appreciated u...sir thank you for replying@@BonMj
Nice ❤
Thanks
Hi sir
I have a doubt sir DAIKIN ducted unit drain pump open but incoming fcu power have not turn off pump still running rights that time water reverse back what is the cause of problem drain pump or drain pipe
Hi sir
How to check linear expansion valve resistance reading in Mitsubishi indoor FCU.
Good lecture! Sir, please advise how to test run with outdoor push button switch, as i find the BS4 is for pump down?
Vrv?
@@BonMj Super inverter, your model RZR71
@@mymusic-tp1bh just long press test button.
@@BonMj BS1-Mode, BS2-Set, BS3-Return, BS4-Pumpdown, find no test button on outdoor pcb
@@mymusic-tp1bh th-cam.com/video/RleCvum-bEQ/w-d-xo.html
Hi Mr Bon may i know your digital multimeter brand and model, thank you in advance.
No more this type meter, i also thinking to change new once, cant find anymore, i use it more than 12yrs.very good brand.
🧿
Thanks
Sir daikin vrv 3 inverter compressor is dc or ac
DC
@@BonMj thanku sir
Sir, what is the cause of error E5 on the Daikin RZR140LVVM(4) floor standing AC? please explain how to handle it
Inverter compressor lock
sir the anothere indoor not cooling but athere indoor cooling good vrf mitsubishi what possible causes sir
Check LEV
sir thanks but if icheck i use computer or there are anyway to how unit to indentify where unit defective indoor
i dont have computer or laptop to check the unit there are anyway to check LEV defective
Hello bon sir mistibushi error code 7113 who to slove sir video apply your channel
Check Pcb incoming
Pcb setting
Or wrong model Pcb
Bon sir is an indoor which is master wired remote is not getting any error in it and its fan motor is not running and running without direct pcb then have ordered new pcb yet same problem is coming plz help sir
May be pcb
Sir, I have asked for a new one, still the problem is coming in the same mode number FXMQ50ARV16
PCB model FXMQ-NVE6
EB16046(c)
Even after installing a new PCB, the same problem is coming, if you run the fan motor without a PCB, then it is running fine and this problem is coming only in the master indoor, reset the outside door and has also done test mode
Pls help me: when turning off the cb to clean the daikin vrv indoor unit, how can the system not report an error? Tks
VRV3?
Vrv 4
does it have to mode 2.90?
@@cantran5730 Normally VRV4 one of the indoor faulty or miss communication, you try to reset(push the return button more than 10 second)and wait untill the led off.
@@cantran5730 this is for emergency use, like say one of the indoor miss communication ,but this mode only for 24hrs
Hello bong air con dailkin inverter compresor not working fan not work .out door not work .in door working normal. No show error cord
Check outdoor thermistor
@@BonMj l checked oready bong .
I change PCB out door and indoor also not working.
Hello bon
Hi
@@BonMj on problem mitsubishi electric vrf .but run colling not properly only 5 Ampere teck
✋👍🤳🛠️🇹🇷
Thanks bro
Hi sir
Hi master BON
can help Daikin inverter error code H6 H8 and H9
THANK
DAIKIN INVERTER outdoor model
3MKS71ESG
Check thermistor
Noted thanks
Eev problem
Yes
Daikin error e1
Check outdoor pcb