haier inverter ac outdoor fan motor 40 watt ki hoti hai kia issay 60 watt ascon say replace karsaktay hai haier ki motor faulty hogi thi, replace karnay say fan ki speed kafi fast hogi hai kia iskay koi nuksanat bhi hosaktay hai pcb ya circuit main.
@@SJTechnicalSupport ak aur hai youtube pe sir ji unka kahna hai digit aye tu koi masla nahi hai samajh nahi aa raha kya kiya jaye any way thanks sir ji
6 number speed ka wear band may nahi batayga,lakin chalu mai black or 6 per 0-6 v dc batay ga speed ka hisab sai,or 7 number fidback ka usper nahi batay ga ,pcb to motor cominecet karnay kay liya,7 number ko FG boltay hai(fiquenc genarator)
Time waste mat karo. Tumko wires ginke bataneki zarurat nahi hai, humko dikhta hai. 1 aur 4 ne open bataya to motor sahi hai ye to bakwas hai, arey under se bhi open ho sakti hai.
4 core ka wire ke saath out door to indoor wiring pe video bna dijiye aap ka video ek no hai
Apka samghame ka tarika bahut badiya h
Thanks sir
Naice sar
Very helpful video sir ji thankyou sir ji
Super
Very good l understand you are very intelligent
Thanks for sharing such a good technical video
Nice video sir
Adura gyan he sir
Aap se aasha next video Pura Gyan milega
Resistance kitna ayegi? Asa na ho ki coil disconnected?
Nice
Agar wire break hun gi to clamp meter yahi show karay ga
The first fan motor spoil
Second fan motor good
Correct?
Thanks bro
Nice video bhai
Three heck wire Hitachi inverter AC
Out door fan motor AC or DC how check please tell
Bahut achhabhai
SK ji out door fan motor how check
Thank you sir ji
Thank bhai
Welcome sir thanks
Good joop
Carrier inverter AC blower motor speed slow please tell
मल्टीमीटर से कन्फर्म नहीं किया जा सकता है भाई साहब
Hello
Sameer Bhai Kay hal hay
Thankyou sir
What about 5th and 6th wire
V nice
DC motor ohms value
haier inverter ac outdoor fan motor 40 watt ki hoti hai kia issay 60 watt ascon say replace karsaktay hai haier ki motor faulty hogi thi, replace karnay say fan ki speed kafi fast hogi hai kia iskay koi nuksanat bhi hosaktay hai pcb ya circuit main.
Nahi koi problem nahi hogi
Motor dc hoga to pcb may jow capacitor hai o jaldi kharap hoga,
@@jahirtechnical jahir bhai aap yaha 🙋♂️
@@jahirtechnical इंवेटर ac me कोई capicter nhi आता
Bhai ise direct start nahi kar sakte hh
Agar kar sakte h to upay bataye
Nahi ho payga bhai
ON beep 😂 NO beep
Bhaiya ji agar jakk change hua to 1aor 4 kaise pta karege
नहीं hoga bhai आप bilkul paresan मत ho
@@SJTechnicalSupport ok
Kya ye dayrect chal jayegi
Yeah 6 number or 7 number wala q check nahi kia
Agar digit aye tu sir g
To be kharab h
@@SJTechnicalSupport ak aur hai youtube pe sir ji unka kahna hai digit aye tu koi masla nahi hai samajh nahi aa raha kya kiya jaye any way thanks sir ji
@@SJTechnicalSupport uska name hai jahir technical please check video sir g
Video me prof ke sat h AP aache se Dekho ge video to apko samajh me aaye ga Kya sahi h kya Galat h ok
Hlo
6 aur 7 number ko check karna hai ki nahi
Band pe nahi
chalu pe sapli chek hote h 6 our 7 ok
Chalu pe continuty check karna hai ki voltage
bhai band pe apko continuti chek karna h isse apke motar chek hote h ok
6 or 7 chalte pe chek karne par kya aana chahiye sir
6 number speed ka wear band may nahi batayga,lakin chalu mai black or 6 per 0-6 v dc batay ga speed ka hisab sai,or 7 number fidback ka usper nahi batay ga ,pcb to motor cominecet karnay kay liya,7 number ko FG boltay hai(fiquenc genarator)
Fid back check Nahi hota
Motar open rahi to batayega nahi
Time waste mat karo. Tumko wires ginke bataneki zarurat nahi hai, humko dikhta hai.
1 aur 4 ne open bataya to motor sahi hai ye to bakwas hai, arey under se bhi open ho sakti hai.
Bilkul galat tarika. Aap barober khud Sikh lo aur fir video banao
Supper
Thank you bhai