आपका vdo बहुत ही बढ़िया और सरल है, चाहे time लगे अप एकदम जीरो से पूरा एक एक components के बारे में details मैं बताते हैं जो समझ ने में आसानी होता है 🙏🙏
Great video, kindly also make a video of the same connections with L & T MK1 contactor, GIC under/over relay and GIC liquid level controller along with Auto and Manual changeover switch.
Hello Sir, Please let me know which contactor will be best to use if i have to connect my household electricity load like Air conditioner, submersible pump, washing machine, geyser, TV, fans, etc. In my locality, power fluctuation is very frequent so I want to use VMR with contactor as you showed in the video.
Very good informative video Can you please tell me company name and model name of each component and there capacity 1)MCB Model name company name and capacity 16A , 20A, 25A ,32A etc 2) power contacor company name model name and capacity 3) Voltage controller company name model name capacity 4) single MCB Company name capacity 16A,20A,25A,32A Also I am not getting use of that last single MCB Pl. Provide details on above 4 points Thanks
Mera ek panel mai this relay mai upper side mai 3 phase or nutreal arehai niche 15 or 16 phase arehai lekin relay kha power led on nahi hai age line bhi ja nahire kya problem ho sakthe
Thanks a lot sir🙏🙏🙏 is topic pe video la ne ke liye sir muje app ke help chaiye mera ek 62kva three phase genset hai or me live sound reinforcement karta hu to muje ek 62kva power distributor banana hai jisme over voltage and under voltage protector,over and under frequency protection,over power factor and under power factor and phase sequence protection,and phase failure,neutral protector and surge protector chaiye to kya app please mera help karoge 🙏🙏🙏. Yeah mjue or mere jaise bahot logo ko helpful rahega🙂
Thanks sir, can you make controlling of 3 input contractors with single output? I have i EB main power anf have 2 DG sets. Need to make controling ckt when EB fails master DG start automatically and if DG 1 fails to start due to any reason, then DG 2 automatically start after some defined time delay. Once EB restore, DG automatically shutndown and power goes from EB contactor. Please make 1 video on this.
Maine same cnnection GIC 800 DMS 120 ke liye apply kiya... Lekin pahile 5second ke liye on hota hai lekin uske bad trip ho jata hai aur red fault ka light on ho jata hai... Kya fault ho sakta hai
Dear Sir, aap ye bataye ki contractor k coil A1 per aap B phase add kia hai .yadi B phase UV hota hai to coil ko off ker dega relay. aap ye bataye yadi R phase UV hota hai to us time kya react Karega relay.?? kya us time off Karega coil ko ? R phase to add nhi hai coil ko. I am waiting ur valuable feedback.
hello sir ..hame GlC - Cat ID- ND21DF Series SM175 ke bare me ek video banke hame connection ke bare me details samjai .. Ye ham aapki request karate he..
Mene reley ke NC me se contactor ko power diya but contactor on nahi ho raha he ,NO me se contactor ko power de raha hu tab contactor on ho raha he,aisa kyu ho raha he ?
Hello Sir, Maine yahi circuit follow karte hue connection kiya hai. VMR hai GIC SM800 DMA 220. But ye circuit trip nahi ho raha hai jab kisi ek phase mein voltage 200V se niche drop kar raha hai...main Under voltage 200V set kiya hai but VMR trip nahi ho raha hai. Plz mujhe help kijiye. Kya VMR mein kuch defect hai ya circuit mein.
आपका vdo बहुत ही बढ़िया और सरल है, चाहे time लगे अप एकदम जीरो से पूरा एक एक components के बारे में details मैं बताते हैं जो समझ ने में आसानी होता है 🙏🙏
बहुत अच्छा, जितने प्रसंसा की जाए कम है आपने इतने सरल भाषा का उपयोग किया है कि सभी Doubt Video को देख के ही clear हो जाती है....👌👍
Thanks
Han ji Sar trip kaise kiya jata hai
9525918336
Sar ji apna number send kar dijiye
Badi hi sehjta se aap ne samhjya...nice way of explaining things
Great video, kindly also make a video of the same connections with L & T MK1 contactor, GIC under/over relay and GIC liquid level controller along with Auto and Manual changeover switch.
Bahut accha samjhaya hai sirji, please ELR connection with MCCB bhi sikhao 🙏
Very knowledgeable video sir
Very nice video sir. I really like it. thanks you so much. God bless you
Well knowledgeable video thanks you sir
Very good explanation,
Excellent sir,
I live in UK and your way of explanation , videos very helpful... So I subscribe your channel now for future video...👌👌
Hello Sir,
Please let me know which contactor will be best to use if i have to connect my household electricity load like Air conditioner, submersible pump, washing machine, geyser, TV, fans, etc.
In my locality, power fluctuation is very frequent so I want to use VMR with contactor as you showed in the video.
Excellent explanation 👌
Well explained... Thq u
I learnt. Well explained. 🙏🏻🙏🏻
Please subtitle in English.
Nice video. Many thanks.
Very useful video
Very good informative video
Can you please tell me company name and model name of each component and there capacity
1)MCB Model name company name and capacity 16A , 20A, 25A ,32A etc
2) power contacor company name model name and capacity
3) Voltage controller company name model name capacity
4) single MCB
Company name capacity 16A,20A,25A,32A
Also I am not getting use of that last single MCB
Pl. Provide details on above 4 points
Thanks
Nice sir
Dear sir nice explanation useful kindly arrange to add 3 phase surge suppressor to get perfect and quick response
Bhai ghar ke liye aisa circuit use kar sakte hai?
good
Good video sir
Great explain
Very nice information
Good explanation
Zabardast g
Great videos... pl. highlight the connection points with some pointer/highlighter when mentioning the name.
Thanks sir ji
Super thank you sir thank you
very very nice
Thank you sir ❤
Very good sir iski comments se wiring diagram batayen
Sir cold room pe video banaye
Ye realay 3 phase power milega tabhi sens karega??
is aik rely pr kitni 3ph motor apply kr sakty hain?
Good ! VERY INFORMATIVE
Very Nice
Is relay ko 240v single phase monitoring kar skte h plz reply...
Mera ek panel mai this relay mai upper side mai 3 phase or nutreal arehai niche 15 or 16 phase arehai lekin relay kha power led on nahi hai age line bhi ja nahire kya problem ho sakthe
Dear I am use this relay for house wiring is it ok
very Good
Thanks👍
Relay ko single phase connection monitoring kar sakte hai...?
Thank you bhaia
Thank you
Thank u sir
Device ka internal circuit digram mil payega kya sir
❤
Sir single phase motor me ye device use carsakta he?
Last main indication light lagana zaroori hai kya ,qk already 3 phase k leay indication lights hain phr aesa q ,,,plz batana
Sir hi mera 63 amp Ka load hai
To main contecter kon sa lagana hoga pls batana Thanks in advance
Thanks sir
Nutul cut ka problem bhi solve ho jayega na sir
Han.
Kya ham ya cercit house MN istmal kr saktan han
great video single phase motor me ye device use kaise carsakta he?
Ye 3 phase ke liye hai.
Sir mcb tp &s.p kitne amp ki he & cotectar kunsa he batai
Thanks a lot sir🙏🙏🙏 is topic pe video la ne ke liye sir muje app ke help chaiye mera ek 62kva three phase genset hai or me live sound reinforcement karta hu to muje ek 62kva power distributor banana hai jisme over voltage and under voltage protector,over and under frequency protection,over power factor and under power factor and phase sequence protection,and phase failure,neutral protector and surge protector chaiye to kya app please mera help karoge 🙏🙏🙏. Yeah mjue or mere jaise bahot logo ko helpful rahega🙂
Sir Pata kaise lagaen ki rectifier LG Kom ka hai yah delta ka
Ham same wiring connection sm 800 ke liye kar sakte hai kya
If Nuetral Break down from main supply, it's stop main line contactor?
Bhai soft stater kai bare main videos banayein
काॕन्ट्याक्टरका काॕईल व्होल्टेज देना जरुरी है.
ON DELAY ke bare me bataya hi nahi
Can this circuit is useful for nitural faliury circuit
Sir,
If we want to connect vmr sensing phases from out put of power contactor.
Then is it work properly or not.
Not working.
Bypass mcb set karni ho to wiring kese karte he
Safe voltage motor ? UV, OV, single and 3 phase motor.
I went to know that vmr setting points.
सर यह कितने मोटर पर लग सकता है
3 phase VMR ko single phase mein kise connection Karen
Sir 3 phase uvr connection kese korna hai.?
I am looking for similar device to limit high voltage DC current. Any ideas?
Sir push botton se on of kese hoga
Sir water chiller three face wiring kaise karen
اس کو اٹو اور مینول میں چلانے کے لیے کیا استعمال کریں
सिंगल फेस 32 एम्पियर तक करना होगा तो क्या करे।
Thanks sir, can you make controlling of 3 input contractors with single output? I have i EB main power anf have 2 DG sets. Need to make controling ckt when EB fails master DG start automatically and if DG 1 fails to start due to any reason, then DG 2 automatically start after some defined time delay. Once EB restore, DG automatically shutndown and power goes from EB contactor. Please make 1 video on this.
This circuit will PLC based.
Sir ager single phase hai to kis tara connection karein
Hii sir
Maine same cnnection GIC 800 DMS 120 ke liye apply kiya... Lekin pahile 5second ke liye on hota hai lekin uske bad trip ho jata hai aur red fault ka light on ho jata hai... Kya fault ho sakta hai
Singal mcb kyu lagaya he ? Uska kam kya he ?
Hallo sir,,,can you apply it with manual COS please?
Any different betwee GIC MG73BH SM500 AND GIC MAC04D0100 SM500
How about time response for over/under voltage ? < 200ms ?
Dear Sir, aap ye bataye ki contractor k coil A1 per aap B phase add kia hai .yadi B phase UV hota hai to coil ko off ker dega relay. aap ye bataye yadi R phase UV hota hai to us time kya react Karega relay.?? kya us time off Karega coil ko ? R phase to add nhi hai coil ko. I am waiting ur valuable feedback.
Tino phase me se kisi ka UV hone par yah Circuit output nahi dega.
Sir mere me MMR relay Kam nahi kar Raha hai hog ka
Will it work in 400c/s
Ghar mae Kaise canaction korae 3 phase over voltage
Sir aap panel ke Saath bata sakte hai video ko
हेलो सर टाइमर लेवल शंशर ओर। फेशाफेलर रिले का सीरीज वायरिग बतव
Sir fault hone se reset kese hoga
Phase sequence ultah ho jaye to kya kare iskeliye koyi device Hi kya
Sir ji he software konsa ahe
Sir preventre nc point coil connection wright
Sir ov को 110 परसेंट के ऊपर set करने पर nc no चेंज हो जाते हैं ऐसा क्यों हो रहा है
Please explain
sir, is it possible protect the load when neutral failure 3 phase 4 wire system
Yes.
@@ElectricalHome kindly make a video sir
hello sir ..hame GlC - Cat ID- ND21DF Series SM175 ke bare me ek video banke hame connection ke bare me details samjai .. Ye ham aapki request karate he..
Mene reley ke NC me se contactor ko power diya but contactor on nahi ho raha he ,NO me se contactor ko power de raha hu tab contactor on ho raha he,aisa kyu ho raha he ?
No sería posible. Verlo en español
Hello Sir,
Maine yahi circuit follow karte hue connection kiya hai. VMR hai GIC SM800 DMA 220. But ye circuit trip nahi ho raha hai jab kisi ek phase mein voltage 200V se niche drop kar raha hai...main Under voltage 200V set kiya hai but VMR trip nahi ho raha hai. Plz mujhe help kijiye. Kya VMR mein kuch defect hai ya circuit mein.
Check your relay settings.
Sir kya aap ye relay Ka company name bata sakte hai?
Gic