How to set up a ferroli boiler

แชร์
ฝัง
  • เผยแพร่เมื่อ 31 ม.ค. 2025

ความคิดเห็น • 63

  • @jenniferedmunds572
    @jenniferedmunds572 4 ปีที่แล้ว +2

    I have come to you on several occasions and you have always given me the answer, thanks

  • @colettereilly5589
    @colettereilly5589 ปีที่แล้ว

    6:23 the fuse on the wall next to the boiler stopped working. We replaced it with a new fuse but our boiler won’t light up. It’s a farolli boiler.

  • @neddipa3904
    @neddipa3904 ปีที่แล้ว

    Hi there, do you have the parameters list for a HE Plus 31C. I know they are factory set but it would be good to check the parameters . Many thanks

  • @mp2172
    @mp2172 5 ปีที่แล้ว +1

    Is there a reset to default on this? I think I may have adjusted other parameters by not knowing what I'm doing. If not, I think P01 would be the most likely to have been adjusted, could you provide the setting for that please?

    • @Narcobranco
      @Narcobranco ปีที่แล้ว

      Did you figure out a way? I ve made the same mistake and now mine will go to 3 bar when turning on hot water and the heat will be on nonstop

  • @DaleMarriott1337
    @DaleMarriott1337 11 หลายเดือนก่อน

    Hi do you know what causes A41 and how to fix it. I have it servived and they go in the boiler and all time I have problems when they done the service. I brought the flow sensor which seems to be a magnetic switch. however looked in the boiler the connection looks good. its a optimax he31c is parameters same for that boiler?

    • @theferroliman2067
      @theferroliman2067  11 หลายเดือนก่อน

      F41 is poor circulation..first check the sensor on the left hand side of heatexchanger it's black and white it could be loose and not sitting on the pipe correctly.

    • @DaleMarriott1337
      @DaleMarriott1337 11 หลายเดือนก่อน

      @@theferroliman2067 do you have a part code and can i get to this by just removing the white cover? I checked the bottom sensor on the flow switch and a blue wire came out of that i have taped it back in to the connector but it still trips so im thinking its this sensor your talking about. Oh by the way its A41 not F41

  • @levelont5560
    @levelont5560 6 ปีที่แล้ว +1

    Is there a document where all menus and options are described? Haven't been able to find one at their home page!

    • @theferroliman2067
      @theferroliman2067  6 ปีที่แล้ว +1

      You won't find one ...only the ferroli engineers have them .As homeowners have a tendency to fiddle around .Hence why I've shown the key parameters thats really any use anyone to actually change ...

  • @Itisfinished.
    @Itisfinished. 4 ปีที่แล้ว

    Great help bro,,thank you

  • @nareshpalsingh1236
    @nareshpalsingh1236 4 ปีที่แล้ว

    Heating is working fine

  • @mohammedelibrahymy2524
    @mohammedelibrahymy2524 2 ปีที่แล้ว

    اليجزيك بالخير شكرا نوريد مزيد الشرح

  • @cineymatic
    @cineymatic 5 ปีที่แล้ว

    How to resolve A01 error. Other gas appliances are working fine.

  • @ricknotnorris
    @ricknotnorris 4 ปีที่แล้ว

    Hi is it the same set up for ferroli optimax he plus 38c .please

  • @السباكةالحرفين
    @السباكةالحرفين 2 ปีที่แล้ว

    شكرا جزيلا لك أستاذ
    من فضلك كيف يتم معالجة المشكل f07

  • @ivanrely1158
    @ivanrely1158 ปีที่แล้ว

    👍(A03 - Feroli BLUEHELIX PRO 25C)

  • @nareshpalsingh1236
    @nareshpalsingh1236 4 ปีที่แล้ว

    Hi I have ferolli f24 Combi , we have no hot water coming from the boiler please help

    • @theferroliman2067
      @theferroliman2067  4 ปีที่แล้ว

      You may need an engineer to repair this ...it could be anything . Sensors ,fan parts , stuck flowmeter if u have heating then u need to see if the tap light illuminates when the tap is turned on that'll answer a few questions if it does or doesn't

    • @nareshpalsingh1236
      @nareshpalsingh1236 4 ปีที่แล้ว

      @@theferroliman2067 thanks

  • @bellifanazim5857
    @bellifanazim5857 3 ปีที่แล้ว

    Please how to resolve F05 problem thank's

    • @theferroliman2067
      @theferroliman2067  3 ปีที่แล้ว

      This fault needs an engineer visit ...it could be expensive guessing as it could be at least 4 different parts or adjustments

    • @bellifanazim5857
      @bellifanazim5857 3 ปีที่แล้ว

      @@theferroliman2067 thank you for your help please which part can be changed

    • @theferroliman2067
      @theferroliman2067  3 ปีที่แล้ว

      @@bellifanazim5857 it could be a circuit board, fan ,air pressure switch (if it has one) , a fan Venturi adjustment .

  • @robertt6430
    @robertt6430 5 ปีที่แล้ว

    When I select parameter 6 I can only choose between one and three can you help.

  • @ghebby46gheb7
    @ghebby46gheb7 3 ปีที่แล้ว

    hi. I need to put the boiler in stand-by mode (as requested in the manual to change between natural gas to LPG) but I don't know how to do that. can you help me? thanks

    • @theferroliman2067
      @theferroliman2067  3 ปีที่แล้ว

      You'll need to tell me what boiler u have as there's different ways of setting up the LPG in the parameters. Plus some need injectors replacing aswell .

    • @ryanhall4083
      @ryanhall4083 3 ปีที่แล้ว

      Same question mine is a sky eco 11l

    • @theferroliman2067
      @theferroliman2067  3 ปีที่แล้ว +1

      @@ryanhall4083 if you bought you water heater as a natural gas type then u need someone gas safe registered to convert it as the injectors aren't LPG.And set up the circuit board for LPG aswell .

    • @ryanhall4083
      @ryanhall4083 3 ปีที่แล้ว

      @@theferroliman2067 Thank you, I guess that will cost a fortune! Thanks for the help

    • @ryanhall4083
      @ryanhall4083 3 ปีที่แล้ว

      @@theferroliman2067 I just double checked, this was the description Ferroli 11L LPG Room Sealed Water Heater & Flue Replace Morco F11

  • @zakariazizou1639
    @zakariazizou1639 4 ปีที่แล้ว

    Please help me Unother problème a 15 chaudières ferroli diva

  • @theferroliman2067
    @theferroliman2067  6 ปีที่แล้ว +1

    More information is in the description if you press the arrow/triangle button rhs

    • @claudiasantos8905
      @claudiasantos8905 6 ปีที่แล้ว

      Dave Allum boilers
      Hi
      I have a ferroli f24
      It's showing A01 fault
      Do you know what to do?

  • @mikeb-hn2xu
    @mikeb-hn2xu 6 ปีที่แล้ว

    when i select parameter 6 on mynodena 27c he i do not get a percentage of up to 100% i can only select between 1 and 7

    • @theferroliman2067
      @theferroliman2067  6 ปีที่แล้ว

      This one doesn't cover the MODENA he ... You shouldn't need to adjust the output on a MODENA . Bit if you do, it's parameter 13 .

    • @robertt6430
      @robertt6430 5 ปีที่แล้ว

      When I select parameter 6 I can only choose between one and three.
      This is a demicondes f28 can you help .
      Cheers.

    • @tablireparationchaudiere9551
      @tablireparationchaudiere9551 5 ปีที่แล้ว

      F7 érror f7 érror

    • @tablireparationchaudiere9551
      @tablireparationchaudiere9551 5 ปีที่แล้ว

      Bravo do you give me paramaitre ferrolli 😰😰😰😰

  • @jjohnson_horse_rider_soulitons
    @jjohnson_horse_rider_soulitons 5 ปีที่แล้ว

    Hi how do I raise the temperature on my boiler too more than 50??

  • @enerikkanani1074
    @enerikkanani1074 19 วันที่ผ่านมา

    Error a3 ferroli?

  • @aliraheem9872
    @aliraheem9872 6 ปีที่แล้ว

    my boiler display - - what to do ?

  • @dyll3r
    @dyll3r 5 ปีที่แล้ว

    hi , i want all default parametrii on nr 1..to16 please

  • @mahmoudbenahmed6404
    @mahmoudbenahmed6404 5 ปีที่แล้ว

    Nice

  • @frankalexander6629
    @frankalexander6629 2 ปีที่แล้ว

    Doesn’t work on the HE 31c! P6 & P12 you can’t set up the % for number of radiators and P12 you can’t adjust the temperature of the hot water. I have HW but no CH and thought I would try and tell it how many radiators (2) it works to. As I found out, this doesn’t work!

    • @theferroliman2067
      @theferroliman2067  2 ปีที่แล้ว

      This video isn't for that boiler...it's for other models domicondens, he 26c , íboiler, eurotherm
      If you listen from the start it tells you what boiler model it's for

    • @aleksandarprashkov
      @aleksandarprashkov 2 ปีที่แล้ว

      @@theferroliman2067 can you share which are the parameters for range rating the power on the HE PLUS 31c?

    • @abdoudouarna2563
      @abdoudouarna2563 ปีที่แล้ว

      Have error f05.

  • @robertt6430
    @robertt6430 5 ปีที่แล้ว

    Domicondens f28

  • @zakariazizou1639
    @zakariazizou1639 4 ปีที่แล้ว

    Stp problème f 05 ferroli diva

    • @theferroliman2067
      @theferroliman2067  4 ปีที่แล้ว +1

      This fault is normally a circuit board fault

    • @zakariazizou1639
      @zakariazizou1639 4 ปีที่แล้ว

      @@theferroliman2067 It turns on and off, but most of the time is off

    • @zakariazizou1639
      @zakariazizou1639 4 ปีที่แล้ว

      When placing the cover, it stops forever

    • @theferroliman2067
      @theferroliman2067  4 ปีที่แล้ว

      @@zakariazizou1639 F05 will depend on which boiler model u have ... Pcb , fan , air pressure switch, clean fan or adjust fan Venturi ..are the possible problems

    • @zakariazizou1639
      @zakariazizou1639 4 ปีที่แล้ว

      @@theferroliman2067 thanks very match gys ❤❤

  • @علآءالدينبسمةأمل
    @علآءالدينبسمةأمل 2 ปีที่แล้ว

    Paramètres ferroli diva c32