Consertando a Falha F084 WEG AUTODIAGNOSE | EDUCADRIVES

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ต.ค. 2024
  • Quer aprender a consertar inversor de frequência?
    metododeconser...
    4 Testes com 1 multímetro - Método 4T:
    metodo4t.fun/
    Dominando 6 principais marcas de Inversor de frequência:
    guiadosdrives....
    #inversordefrequência #softstarter #educadrives #weg #abb #siemens #rockwell #danfoss #schneiderelectric
    Sigam nossas redes sociais
    TH-cam
    / educadrives
    FACEBOOK
    / educadrives-. .
    INSTAGRAM
    ....
    TELEGRAM
    t.me/educadrives
    SITE
    educadrives.com

ความคิดเห็น • 36

  • @yen7569
    @yen7569 หลายเดือนก่อน

    Tenia mal colocado el flex, gracias a este hombre le di solución saludos ..

  • @kentrols
    @kentrols 7 หลายเดือนก่อน

    I don't speak Portuguese and this video was still helpful, great job.

  • @Eaidomhouse
    @Eaidomhouse 5 หลายเดือนก่อน

    Quero agradecer ao vídeo, consegui eliminar essa falha através da explicação, simples e objetivo parabéns ao canal.

  • @paulo5012
    @paulo5012 ปีที่แล้ว

    Quero agradecer pelo vídeo, conseguimos resolver a falha 84, era o cabo flet mal conectado, retiramos, passamos limpa contato, equipamento de volta a operação. Valeu 👍👍👍👍

  • @canaldamanutencao4446
    @canaldamanutencao4446 11 หลายเดือนก่อน

    Top. Peguei um inversor aqui com essa falha fiz um limpeza com limpa contato e o cabo flat estava com mal contato. Valeu pela dica.

  • @antoniooliveira6564
    @antoniooliveira6564 2 ปีที่แล้ว +1

    Excelente, show de bola.

    • @EducaDrives
      @EducaDrives  2 ปีที่แล้ว

      Show Semana do Conserto está chegando! Participe link: educadrives.com/semana-do-conserto-inversor-de-frequencia-e-soft-starter

  • @claudiopaliosa5725
    @claudiopaliosa5725 2 ปีที่แล้ว +1

    Bom dia. Muito bom!!!!!

    • @EducaDrives
      @EducaDrives  2 ปีที่แล้ว

      Show, participe da Semana do Conserto! Faça sua inscrição! Link educadrives.com/semana-do-conserto-inversor-de-frequencia-e-soft-starter

  • @welbertealves9457
    @welbertealves9457 2 ปีที่แล้ว +1

    Boa noite Welberte da empresa FIXTRONIC Eletrônica Industrial

    • @EducaDrives
      @EducaDrives  2 ปีที่แล้ว

      Show Semana do Conserto está chegando! Participe link: educadrives.com/semana-do-conserto-inversor-de-frequencia-e-soft-starter

  • @iurymatias1299
    @iurymatias1299 7 หลายเดือนก่อน

    No CFW500 tem um jump escrito STO que foi removido com o inversor energizado, apos isso ele deu essa falha F084, será que esse jump estragou os circuitos internos?

  • @eng.gehyprado1718
    @eng.gehyprado1718 2 ปีที่แล้ว +2

    Esse 5V deve ser no emissor LED do foto, pois na saída geralmente trabalha com 18V, até porque a porta do IGBT é MOS, o que precisa de 15 a 20V mais ou menos para ligar o Transistor.

    • @EducaDrives
      @EducaDrives  2 ปีที่แล้ว +1

      Show Semana do Conserto está chegando! Participe link: educadrives.com/semana-do-conserto-inversor-de-frequencia-e-soft-starter

  • @Aldacirctba
    @Aldacirctba 6 หลายเดือนก่อน

    Quando da 1001h tem alguma ideia?

  • @paulotombolato5972
    @paulotombolato5972 5 หลายเดือนก่อน

    Estou com um CFW700 com F084 e 1001h no P642, aluguem sabe o que é este defeito?

  • @rpsstec5933
    @rpsstec5933 2 ปีที่แล้ว +1

    Boa noite. Uma dúvida, vc disse que o optoacoplador do sistema de gatilho é o HCNW 4503 mas esse não seria do circuito de sobrecorrente? A do gatilho não seria o HCPL 3120 ou 3150?

    • @italoquaglioify
      @italoquaglioify 2 ปีที่แล้ว +1

      Kkkk

    • @rpsstec5933
      @rpsstec5933 2 ปีที่แล้ว +1

      @@italoquaglioify não entendi o kkkk

    • @EducaDrives
      @EducaDrives  2 ปีที่แล้ว +3

      @@rpsstec5933 Isso mesmo só dei um exemplo de CI. O importante é você entender aonde que pode ser o problema da Falha F84!

    • @italoquaglioify
      @italoquaglioify 2 ปีที่แล้ว +1

      O foi mal eu não entendo nada

  • @jorgeburdogue4838
    @jorgeburdogue4838 ปีที่แล้ว

    Boa tarde temos um inversor com esse erro toda vez que da pico de energia ou desliga o disjuntor de força da esse erro no inversor ai vc volta inversor pra modelo de fábrica a falha sai só que tem que parametrizar tudo novamente o que pode ser

  • @eletroboava
    @eletroboava 2 หลายเดือนก่อน

    O meu não aparece o P000

  • @Diego-lx4ui
    @Diego-lx4ui 2 ปีที่แล้ว +1

    Isso tudo serve para o CFW de 400A? Sabe onde conseguir a placa de controle?

  • @roninhoamaral9512
    @roninhoamaral9512 2 ปีที่แล้ว +1

    Boa noite professor as live está sendo mais cedo

    • @EducaDrives
      @EducaDrives  2 ปีที่แล้ว +1

      Geralmente as 20 hrs horário de Brasília!

  • @evertonfernandes4603
    @evertonfernandes4603 9 หลายเดือนก่อน +1

    aqui parâmetro P0642 = 1001h
    Alguma dica?

  • @danielbarros7189
    @danielbarros7189 ปีที่แล้ว

    Cfw 500 como olhar a falha?

  • @moisesteixeira4896
    @moisesteixeira4896 2 ปีที่แล้ว +1

    Boa noite Moises Caldas novas

    • @EducaDrives
      @EducaDrives  2 ปีที่แล้ว

      Show, participe da Semana do Conserto! Faça sua inscrição! Link educadrives.com/semana-do-conserto-inversor-de-frequencia-e-soft-starter

  • @leonardofabiobustosholgu-vo7td
    @leonardofabiobustosholgu-vo7td ปีที่แล้ว

    Hola buenas tardes

  • @dmeletroassistenciatecnica1116
    @dmeletroassistenciatecnica1116 ปีที่แล้ว

    Erro 1001h

    • @Aldacirctba
      @Aldacirctba 6 หลายเดือนก่อน

      conseguiu resolver?