ขนาดวิดีโอ: 1280 X 720853 X 480640 X 360
แสดงแผงควบคุมโปรแกรมเล่น
เล่นอัตโนมัติ
เล่นใหม่
Bahut hi shaandar video
Thanks
Very good
👍
Thanks for sharing, a very informative video...
Please give cellphone iam Ashokkumar.A
Informative video...
Very nice , informative video 👍
Sir thora is acb par aur video banaaiye, aur iska macanisim par bhi
जबरजस्त सर, thank you
Thank
Okay
Sir thora isme macanism par bhi ek video bana dijiye, aapke video se hme bahoot help hota hai,
Thank you sir. 🙏🙏🙏. Sir uv coil & tripping coil & closing coil stranded resistance value & present residence value how much sir? Plz explain sir .
🙏🙏 well explained sir thanks
Nice video sir....🙏👍
Please share video link your friends
Great video sir
Thanks Vinod ji
Nice video is good
Shunt Coil generally 24 Vdc pe kaam karta hai na Sir ji.
Sant release AC aur DC do no supply per kam karti hai voltage 24v, 110v, 230v, 415 v AC& DC ho sakti hai
Okay, yane manufacturers apane hisab se decide karte honge. Got your point. Thank you.
@@Sooohannn manufacturer nhi customer demand krta h apne hisab se
How can I come to get training from you
Kese lagate he vo btaye step by step
Nice video
Dear sir.How to bypass under voltage and shunt relay?Kyoki jab kabhi bypass karni ho to kaise kare Sir.Pls make a video that topic.Regards
राजू जी, shant और अंडर वोल्टेज रिलीज को बाईपास करना हो तो उसके कनेक्शन खोल दें लेकिन अगर ब्रेकर इंटरलॉक तो ऐसा करना रिस्की हो सकता है
इस पर मैं एक वीडियो बनाऊंगा
@@electrogyan6240 thankyou sir
@@electrogyan6240 yes please make one video on this topic.
UV coil ka wire ACB ke kis point PE jata h sir
Potential free contact per
Sir यही मॉडल 3500aps का है दोनों कॉयल सही है होल्ड नहीं होती
3500 A ka ACB L&T ka nahi aata hai L&T me 3200A ke bad 4000A ka ACB aata hai agar ACB hold Nahin ho raha hai to closing coil check Karen , UV release bhi chec kare
Sir karab hai ya sahi hai husse kaise check kare
Release ki coil ko kuchh second ke liye supply se connect Karen agar coil operate Hoti hai to theek hai Varna nahin
Ap multimeter se check kr skte ha
Shunt coil 24vdc pr work krta haii
Aap kehna kya chahte ho
Wo customer pe depend krta h
Sir coi testing kese kartehe kharab/thick patakese chalega
Given rated voltage supply to the coil if coil is operated then coil is ok and if does not operate then coil is faulty.
Ap multimeter se v check kr skte hai
Sir l & t ka acb me wring kise kare
Please explain which type of wiring in ACB
There is a manual come with every ACB, in that manual the details of the control circuit is already present.
@@electrogyan6240 ACB पुरानी है और वायरिग चूहे ने काट दिया तो
CNCS ka meaning and full form bataye
CNCS basically ACB type for example c power, CNCS, Omega this is l&t make ACB type
Bahut hi shaandar video
Thanks
Very good
👍
Thanks
Thanks for sharing, a very informative video...
Thanks
Please give cellphone iam Ashokkumar.A
Informative video...
Very nice , informative video 👍
Sir thora is acb par aur video banaaiye, aur iska macanisim par bhi
जबरजस्त सर, thank you
Thank
Okay
Sir thora isme macanism par bhi ek video bana dijiye, aapke video se hme bahoot help hota hai,
Thank you sir. 🙏🙏🙏. Sir uv coil & tripping coil & closing coil stranded resistance value & present residence value how much sir? Plz explain sir .
🙏🙏 well explained sir thanks
Nice video sir....🙏👍
Thanks
Please share video link your friends
Great video sir
Thanks Vinod ji
Nice video is good
Shunt Coil generally 24 Vdc pe kaam karta hai na Sir ji.
Sant release AC aur DC do no supply per kam karti hai voltage 24v, 110v, 230v, 415 v AC& DC ho sakti hai
Okay, yane manufacturers apane hisab se decide karte honge. Got your point. Thank you.
@@Sooohannn manufacturer nhi customer demand krta h apne hisab se
How can I come to get training from you
Kese lagate he vo btaye step by step
Nice video
Dear sir.
How to bypass under voltage and shunt relay?
Kyoki jab kabhi bypass karni ho to kaise kare Sir.
Pls make a video that topic.
Regards
राजू जी, shant और अंडर वोल्टेज रिलीज को बाईपास करना हो तो उसके कनेक्शन खोल दें लेकिन अगर ब्रेकर इंटरलॉक तो ऐसा करना रिस्की हो सकता है
इस पर मैं एक वीडियो बनाऊंगा
@@electrogyan6240 thankyou sir
@@electrogyan6240 yes please make one video on this topic.
UV coil ka wire ACB ke kis point PE jata h sir
Potential free contact per
Sir यही मॉडल 3500aps का है दोनों कॉयल सही है होल्ड नहीं होती
3500 A ka ACB L&T ka nahi aata hai L&T me 3200A ke bad 4000A ka ACB aata hai agar ACB hold Nahin ho raha hai to closing coil check Karen , UV release bhi chec kare
Sir karab hai ya sahi hai husse kaise check kare
Release ki coil ko kuchh second ke liye supply se connect Karen agar coil operate Hoti hai to theek hai Varna nahin
Ap multimeter se check kr skte ha
Shunt coil 24vdc pr work krta haii
Aap kehna kya chahte ho
Wo customer pe depend krta h
Sir coi testing kese kartehe kharab/thick patakese chalega
Given rated voltage supply to the coil if coil is operated then coil is ok and if does not operate then coil is faulty.
Ap multimeter se v check kr skte hai
Sir l & t ka acb me wring kise kare
Please explain which type of wiring in ACB
There is a manual come with every ACB, in that manual the details of the control circuit is already present.
@@electrogyan6240 ACB पुरानी है और वायरिग चूहे ने काट दिया तो
CNCS ka meaning and full form bataye
CNCS basically ACB type for example c power, CNCS, Omega this is l&t make ACB type