Reset a Hunter Controller - Quick Tip

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 มิ.ย. 2010
  • If want to clear the memory on your controller and start from fresh or if your controller is not responding to your commands, this video will show you how to reset it. Most Hunter controllers are reset to factory defaults the same way. The SRC and SVC lines are the only ones that are reset a little differently.
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 80

  • @edfoster22
    @edfoster22 ปีที่แล้ว +3

    We had a power failure. Two days later, I realized my plants were dry. I tried to run the drip system, but kept getting "Err". My box looks like the one on the right in the video. Resetting fixed the problem. I live in Arizona's Sonora Desert, so lack of water is serious for plants. Thanks for the video. The reset is not intuitive, but it's easy when you follow the instructions.

  • @patriciadourans674
    @patriciadourans674 ปีที่แล้ว +1

    Thank you very much for your video and clear instructions. After several attempts to reset the controller after a power surge, despite having a power surge plug, I was not successful. I followed your instructions and it worked the first time. I was able to reprogram the controller to start irrigating again. Thank you for sharing your expertise.

  • @tobythornton2444
    @tobythornton2444 3 ปีที่แล้ว +1

    Hey this worked great. We had a power transformer blow and totally screwed up the sprinkler system. Did a reset and BAM worked perfectly. Thank you so much!

  • @shamini2811
    @shamini2811 2 ปีที่แล้ว +3

    Thank you so much for teaching us this method of re-setting🙏 Your explanation was very clear and easy to understand. I tried this about 8 times, but finally held on the re-set button for about 12 seconds before releasing my fingers. It really worked. Thank you again!

    • @Hunter_Industries
      @Hunter_Industries  2 ปีที่แล้ว

      Glad it helped!

    • @bradley.r.graham
      @bradley.r.graham ปีที่แล้ว +1

      You have to hold the "minus, right arrow, and program buttons" after you release the "reset" button. It will display your old time, and then flash, and then reset.

    • @imthetrickster1
      @imthetrickster1 15 วันที่ผ่านมา

      More specifically, hold minus, right arrow, PRG. Press reset while holding those buttons (I did for 10 seconds). Release the reset, and continue to hold minus, right and prg till it flashes.

  • @abdullaiq8610
    @abdullaiq8610 6 ปีที่แล้ว

    thank you very much. Mine was not blank, but kind of symbols and L shape things on the screen and I reset and turned back to normal. you saved me money and panic. appreciated.

  • @tmhwriter
    @tmhwriter 7 ปีที่แล้ว

    Very helpful tutorial. Thx for posting it.

  • @Mikebike68
    @Mikebike68 5 ปีที่แล้ว +1

    Wow thank you! I had a power interruption and 5 out of 6 zones stopped responding. Did this? HOLDING those three buttons, 12:00 on the display. Back to controlling all zones.

  • @PastorDavidLBrown
    @PastorDavidLBrown 4 ปีที่แล้ว

    Thank you! That was very helpful.

  • @fredvillanueva9923
    @fredvillanueva9923 4 ปีที่แล้ว +8

    You may have to hold the reset button about 10 seconds (not mentioned in the video.). Also, don’t give up. It took me about 8 tries before it worked.

    • @joiashli7929
      @joiashli7929 3 ปีที่แล้ว +1

      Same for me but it does finally work. When he says “Press Hard” he means “Press REALLY Hard”

  • @rmg180869
    @rmg180869 8 ปีที่แล้ว +1

    excelent tutorial mr

  • @RonnyK737
    @RonnyK737 4 ปีที่แล้ว

    You just saved me a lot of money! Thanks!

  • @gurpalkingra8498
    @gurpalkingra8498 ปีที่แล้ว

    Thank you so much.don’t know what we will do without TH-cam.

  • @mrpapasaun
    @mrpapasaun 8 ปีที่แล้ว

    Same question as the others, how do I reset the Hunter X-core controller?

  • @BoydJones
    @BoydJones 9 ปีที่แล้ว +1

    Thanks a lot!

  • @commieslayer8218
    @commieslayer8218 2 ปีที่แล้ว +1

    For everyone having this or similar type of irrigation controller: I just refurbished the older model of this Hunter Pro C. No chance to reset, display occasional function but no ability to control anything and set up time, zones, date, time, year, reset....
    I replaced 8 electrolytic capacitors which dried out due to sun hitting the unit directly.
    Zebra connector between display and the controller board cleaning, shimming to achieve the best I could to see all display segments. Some still do not show properly but controller works and could be set for watering. Internal battery 3 V like in a desk top PC replacement. Some mentioned here that they replaced the 9 V battery and still no memory function. This 3V battery is responsible to hold programed zones and has to be de-soldered and put new in so it is little technical skill to do. Pricing for parts is about 10 bucks plus the work someone does compare 100 - 200 bucks for new unit. Prevent, if you can the sun hitting it directly, you can place there some obstacle in front of it.

    • @Hunter_Industries
      @Hunter_Industries  2 ปีที่แล้ว

      An instructional video is linked below:
      www.hunterindustries.com/support/pro-c-clearing-controllers-memoryresetting-controller
      If you are still in need of assistance, please contact our technical support team directly at 800-733-2823 Mon thru Fri from 6am to 4pm PST to speak to a technician who can troubleshoot and address your concerns while standing at the controller.

  • @lindacook8819
    @lindacook8819 4 ปีที่แล้ว +1

    Thanks, successful re set.

  • @CodyLee8504
    @CodyLee8504 15 วันที่ผ่านมา

    What causes station surging? I replaced a module and that didn’t change anything. So I wired a couple stations together.

  • @tonygulley852
    @tonygulley852 6 ปีที่แล้ว

    What happens if you disconnect the connector ribbon with the power on? I have gone through troubleshooting and settings the program, I'm not getting water, however, the sprinkler Icon is present. Your suggestion?

    • @tonygulley852
      @tonygulley852 6 ปีที่แล้ว

      Thanks, I tried everything except checking the wiring.

  • @jamesgregorio23
    @jamesgregorio23 7 ปีที่แล้ว

    what if I don't see the water mark by itself only the circled one comes up? what do I do?

  • @culturefan
    @culturefan 10 หลายเดือนก่อน

    Thanks a lot, very helpful.

  • @sbond1963
    @sbond1963 ปีที่แล้ว

    Will any stored programs be gone? Is there a way to retrieve the program?

  • @nikolaosmavranezoulis8914
    @nikolaosmavranezoulis8914 4 ปีที่แล้ว +1

    Hi. i have a hunter pro c the newer version. some days now when the program starts the water is coming out from two zones simultaneously ( for example when it goes to zone 2 the zone 10 is also watering ). can you help me?

    • @nikolaosmavranezoulis8914
      @nikolaosmavranezoulis8914 4 ปีที่แล้ว

      @@Hunter_Industries ok i will try it and i will let you know. Thank you

    • @nikolaosmavranezoulis8914
      @nikolaosmavranezoulis8914 4 ปีที่แล้ว

      i had a problem with two valves. ichanged them and is running fine now. thank you for your help!

  • @PastorDavidLBrown
    @PastorDavidLBrown 4 ปีที่แล้ว

    After resetting my xc 600 sprinkler system I now only have zones 1 through 4. Two zones are missing zones 5 and 6. How do I get back those other two zones 5 and 6 that are not showing in the panel?

    • @commieslayer8218
      @commieslayer8218 2 ปีที่แล้ว

      If the reset didn't work, it maybe the module which is electronically controlled and has in my case the older unit 4 zones. Each zone has a semiconductor which gets energized upon command and sends 24V to the solenoid. It's possible that power outages/brownouts can damage these semiconductors, I opened my and had dried out capacitor which I replaced. Couldn't originally reset so I'm still in process checking everything and my issue may be in the controller board inside the door.
      Sun hitting the unit may dry out caps, push button conductive pads, display connector conductive pad......do your best to prevent water and bugs getting in.

  • @vmp3boys
    @vmp3boys 6 ปีที่แล้ว

    my numbers are garbled with 7 and 8 and wont allow me to work the system. tried replacing battery but did nothing. do i need an entire new box or new control panel or what do i need?

    • @commieslayer8218
      @commieslayer8218 2 ปีที่แล้ว

      If the reset didn't work, it maybe the module which is electronically controlled and has in my case the older unit 4 zones. Each zone has a semiconductor which gets energized upon command and sends 24V to the solenoid. It's possible that power outages/brownouts can damage these semiconductors, I opened my and had dried out capacitor which I replaced. Couldn't originally reset so I'm still in process checking everything and my issue may be in the controller board inside the door.
      Sun hitting the unit may dry out caps, push button conductive pads, display connector conductive pad......do your best to prevent water and bugs getting in.

  • @ricknewkirk3980
    @ricknewkirk3980 5 ปีที่แล้ว

    Good video. However I have a zone that will work when I run it manually as a single station. However in a program, it will not run. There is water running to the heads, but none of them pop up. Any suggestions?

    • @ricknewkirk3980
      @ricknewkirk3980 5 ปีที่แล้ว

      Thanks again. Hunter Pro Series. I only have Program A with start time and run times for 5 stations. The problem is when I "manually run single station" the station runs. When I "Manually run all stations", it doesn't open up even though there is water running to it.

    • @ricknewkirk3980
      @ricknewkirk3980 4 ปีที่แล้ว

      @@Hunter_Industries Yes the station running icon is flashing while running and everything starts fine in program mode. The program will continue to cycle through the trouble zone and move to the next zone when the time is completed.

  • @maxdugout9432
    @maxdugout9432 4 ปีที่แล้ว

    I used to have five zones in the control, but somehow my zone number five is missing. How do I get it back? Thank you!

    • @commieslayer8218
      @commieslayer8218 2 ปีที่แล้ว

      If the reset didn't work, it maybe the module which is electronically controlled and has in my case the older unit 4 zones. Each zone has a semiconductor which gets energized upon command and sends 24V to the solenoid. It's possible that power outages/brownouts can damage these semiconductors, I opened my and had dried out capacitor which I replaced. Couldn't originally reset so I'm still in process checking everything and my issue may be in the controller board inside the door.
      Sun hitting the unit may dry out caps, push button conductive pads, display connector conductive pad......do your best to prevent water and bugs getting in.

  • @antoinetteaiono928
    @antoinetteaiono928 6 ปีที่แล้ว

    So i have 9 zones, for some reason now it only has three zones that show up and will water. Not sure what happened to the other 6 zones. i tried to reset which it did and the zones came back but they wont set not to be watered. Not sure why can you help

    • @commieslayer8218
      @commieslayer8218 2 ปีที่แล้ว

      If it was still programmed for watering these missing zones this may be the issues:
      If the reset didn't work, it maybe the module which is electronically controlled and has in my case the older unit 4 zones. Each zone has a semiconductor which gets energized upon command and sends 24V to the solenoid. It's possible that power outages/brownouts can damage these semiconductors, I opened my and had dried out capacitor which I replaced. Couldn't originally reset so I'm still in process checking everything and my issue may be in the controller board inside the door.
      Sun hitting the unit may dry out caps, push button conductive pads, display connector conductive pad......do your best to prevent water and bugs getting in.

  • @antwiwaa1
    @antwiwaa1 9 ปีที่แล้ว

    Hi Hunter..I've tried resetting an xcore 6 station controller with the same method but it doesn't reset. What do I do?

    • @amri0718
      @amri0718 4 ปีที่แล้ว

      Hunter Irrigation the reader is not working for me, what can I do?

    • @commieslayer8218
      @commieslayer8218 2 ปีที่แล้ว

      Someone suggested to hold the reset button for 10 seconds and if nothing, try more times.
      I had a similar issue and working on it now but this is what can be related to your issues: If the reset didn't work, it maybe the module which is electronically controlled and has in my case the older unit 4 zones. Each zone has a semiconductor which gets energized upon command and sends 24V to the solenoid. It's possible that power outages/brownouts can damage these semiconductors, I opened my and had dried out capacitor which I replaced. Couldn't originally reset so I'm still in process checking everything and my issue may be in the controller board inside the door.
      Sun hitting the unit may dry out caps, push button conductive pads, display connector conductive pad......do your best to prevent water and bugs getting in.

  • @terrybagley5411
    @terrybagley5411 7 ปีที่แล้ว

    What is the problem if the display is blank or very faint, but the controls are still operating?

    • @commieslayer8218
      @commieslayer8218 2 ปีที่แล้ว

      Display connection to board is loose/dried out since it is a conductive siliconized pad sandwiched between the display and controller's board. Sun hitting the unit helps to create these issues/extreme temperatures, rain getting in, tapping on the display by finger damaging it or really old unit. Try to gently touch/puch the display if some numbers/segments come back.

  • @qamardhanani1766
    @qamardhanani1766 ปีที่แล้ว

    My problem is that I have set my system 10 minutes each station but then when it finishes it restart again from station one it does not stop can you please help me with that.

  • @claudiafederer6856
    @claudiafederer6856 8 ปีที่แล้ว

    If I just manually run a program all six of my zones water.l On setting the program set times only four zones show for each program. What happened to the other two zones???

    • @lylejb43
      @lylejb43 7 ปีที่แล้ว

      Hunter Industries k

    • @commieslayer8218
      @commieslayer8218 2 ปีที่แล้ว

      If the reset didn't work, it maybe the module which is electronically controlled and has in my case the older unit 4 zones. Each zone has a semiconductor which gets energized upon command and sends 24V to the solenoid. It's possible that power outages/brownouts can damage these semiconductors, I opened my and had dried out capacitor which I replaced. Couldn't originally reset so I'm still in process checking everything and my issue may be in the controller board inside the door.
      Sun hitting the unit may dry out caps, push button conductive pads, display connector conductive pad......do your best to prevent water and bugs getting in.

  • @user-jh8qp7mr8v
    @user-jh8qp7mr8v ปีที่แล้ว

    thank you
    you're awesome

  • @01aharley
    @01aharley 5 ปีที่แล้ว

    My system continues to go through all stations, starts back at one and goes again, over and over, how do I make it stop after one watering?

    • @01aharley
      @01aharley 5 ปีที่แล้ว

      Up and running! Thank you from a new loyal customer.

  • @rogerking276
    @rogerking276 2 ปีที่แล้ว

    I’m not sure but my older version of this will not stop cycling. It just keeps going through the 7 stations over and over again and doesn’t stop unless I go out there and physically turn the system off.

    • @Hunter_Industries
      @Hunter_Industries  2 ปีที่แล้ว

      Sounds like your programming is repeating. Use this link to learn how to troubleshoot this. www.hunterindustries.com/support/pro-c-why-does-my-system-turn-again

  • @PastorDavidLBrown
    @PastorDavidLBrown 4 ปีที่แล้ว

    After resetting X-CORE - I cannot run the ONE TOUCH MANUAL START AND ADVANCE. How can I fix this? When I press and hold the right arrow button for 2 or more seconds nothing happens. Thanks

    • @PastorDavidLBrown
      @PastorDavidLBrown 4 ปีที่แล้ว

      @@Hunter_Industries All 6 zone's run times are set for 30 min. Thanks.

    • @PastorDavidLBrown
      @PastorDavidLBrown 4 ปีที่แล้ว

      @@Hunter_Industries After resetting the system again and reprogramming everything again, I can now manually run the zones. Thanks.

  • @sarahcrosby3797
    @sarahcrosby3797 11 หลายเดือนก่อน

    We have a new Hunter ICC2 controller with 16 stations or 2 8-station modules. All the sprinklers are working fine on programs A and B. I need to add a program C (or D)for a specific area but it will not recognize any stations above 8. I've sent a note to Hunter customer service but wondered if anyone else has this problem? Thanks.

    • @Hunter_Industries
      @Hunter_Industries  5 วันที่ผ่านมา

      Great idea: contact our customer support department here: www.hunterindustries.com/hunter-technical-support-email-request

  • @DylBuilder1
    @DylBuilder1 2 ปีที่แล้ว

    hello, I have a fairly new (Blue faceplate model) hunter Pro C Controller, Installed in October 2019. it is set up for 16 stations, with the PCM 300 Then on top the PCM 900, and stations 14 15 and 16 are not being used. However The controller Reads Err 14, err 15, and err 16, then forgets everything that was programmed into the controller, even my easy retrieve memory is gone. every time I re-program The Controller, it still does the same thing. Stations 14 15 and 16 have no wires to them, they are just there for expansion. please help, Thank you for your time,
    DylBuilder1.

    • @Hunter_Industries
      @Hunter_Industries  2 ปีที่แล้ว

      This sounds like a glitch. Try removing the PCM900 and inserting it back in, and also doing a reset on the controller may help too. Use the link below to learn how to do this.
      www.hunterindustries.com/support/pro-c-clearing-controllers-memoryresetting-controller

    • @DylBuilder1
      @DylBuilder1 2 ปีที่แล้ว

      @@Hunter_Industries thanks for the info, but as soon as I put the module back in and slipped the switch to the locked power on position it started opening every valve in the system for a split second and did that until it was unplugged. We are working with our local hunter dealer to get a new controller.

  • @elenahernandez9353
    @elenahernandez9353 7 ปีที่แล้ว +1

    Im trying to reset the System to clear various times and programs and I cannot get it to to show 12:00. :(
    have tried several times and end up with different numbers or time.....not 12:00 and when i Press buttons not one of them respond to touch.....everything seems stuck!

    • @elenahernandez9353
      @elenahernandez9353 7 ปีที่แล้ว

      The reset button is on the right Side of panel but cannot find model number...
      Will try again or call ....thanks.

    • @commieslayer8218
      @commieslayer8218 2 ปีที่แล้ว

      Someone here suggested to hold the reset for 10 seconds and try to repeat, if that won't work, this may be the issues:
      If the reset didn't work, it maybe the module which is electronically controlled and has in my case the older unit 4 zones. Each zone has a semiconductor which gets energized upon command and sends 24V to the solenoid. It's possible that power outages/brownouts can damage these semiconductors, I opened my and had dried out capacitor which I replaced. Couldn't originally reset so I'm still in process checking everything and my issue may be in the controller board inside the door.
      Sun hitting the unit may dry out caps, push button conductive pads, display connector conductive pad......do your best to prevent water and bugs getting in.

  • @chessmasternater
    @chessmasternater 5 ปีที่แล้ว

    Any tips for making a remote controller work?

  • @stevegonzales3612
    @stevegonzales3612 2 ปีที่แล้ว

    I tried to reset mine numerous times but it wouldn't reset...it goes back to what is on it? So I've had it off for numerous months now. I can only assume because it won't factory reset...its broken? I've had this box for approximately 6 yrs.

    • @Hunter_Industries
      @Hunter_Industries  2 ปีที่แล้ว

      Hello,
      Below are the reset procedures. If you are unable to reset your controller the control panel will need to be replaced. NOTE: the panel for the older Pro-C (green buttons) is no longer available, you would need to replace the entire controller.
      If your Pro-C controller has blue buttons use the reset below:
      1. Press and hold the program button.
      2. Press and release and the RESET button on the back of the front panel.
      3. Wait until the display shows 12:00 am.
      4. Release the button.
      If your Pro-C controller has green buttons use the reset below:
      1. Turn the dial to the RUN position.
      2. Remove the 9V battery.
      3. Press and hold the , and program buttons simultaneously.
      4. Press and release the Reset button on the back of the front panel.
      5. Release all three buttons when you see 12:00 a.m. on the display.

  • @jorgefelix4948
    @jorgefelix4948 8 ปีที่แล้ว

    hi hunter, how do you reset an x core controller?

    • @nelsonhinojosa1521
      @nelsonhinojosa1521 7 ปีที่แล้ว

      quiero información como resetear en español

  • @PistacchioIceCreamSucks
    @PistacchioIceCreamSucks 3 ปีที่แล้ว

    I have massive amounts of BRIEF power outages where I live. These power outages are roughly 1 or 2 seconds long. Every time this happens, it resets my Sprinkler system. I changed out the battery in the Sprinkler system. Still resets. Solutions?

    • @commieslayer8218
      @commieslayer8218 2 ปีที่แล้ว

      Even if you have a good battery, the power kick/jolt is hitting the sensitive electronic components in the controller and may damage some of these semiconductors. You would need some small version of power backup supply (like for PC but really small) hooked to the main line first and then from the backup to the controller transformer/power-supply to smooth out those nasty kicks we all hate.

  • @gloriagilmore8366
    @gloriagilmore8366 2 ปีที่แล้ว

    Ok