Schematic of a septic tank - Septic Tank P1

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 พ.ย. 2019
  • Structure of sump 3 compartments properly technical, Common sump 3 compartments are compartments, Sediment 1, Sediment 2 or filter compartment. Height of placing pipes Order inlet, outlet pipes, pipes from compartment to settling compartment. The minimum height of the water in the tank is 1.3m..
    A septic tank consists of one or more concrete or plastic tanks of between 4000 and 7500 litres (1,000 and 2,000 gallons); one end is connected to an inlet wastewater pipe and the other to a septic drain field. Generally these pipe connections are made with a T pipe, allowing liquid to enter and exit without disturbing any crust on the surface. Today, the design of the tank usually incorporates two chambers, each equipped with a manhole cover, and separated by a dividing wall with openings located about midway between the floor and roof of the tank.
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 450

  • @phuongnhinguyen5969
    @phuongnhinguyen5969 4 ปีที่แล้ว +11

    Anh ơi.ống ra cao bằng ống vào cũng được hả anh. Nếu từ bể 1sang bể 2không thông đáy có sao k ạ. Mong a trả lời giúp ạ ☺️

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว +9

      Ống ra cao bằng ống vào vẫn được, lưu ý độ dốc ống vào càng dốc càng tốt. Trường hợp độ dốc không đủ có thể hạ độ cao ống vào thấp hơn ống ra để tăng độ dốc cho ống vào, độ dốc nên để tối thiểu 3%. Đẹp nhất thì ống vào cao hơn ống ra 10cm. Đáy không thông thì cặn chỉ nằm ở bể 1, có thông đáy thì cặn sẽ nằm ở 2 bể, bể 1 khi đầy sẽ tràn một phần sang bể 2 như vậy thể tích chứa cặn sẽ tăng lên.

    • @phuongnhinguyen5969
      @phuongnhinguyen5969 4 ปีที่แล้ว +2

      @@S-HOME vậy là k thông đáy vẫn k sao đúng k ạ. Bởi vì nhà e đang làm thợ họ k cho thông đáy. Em thấy mình hướng dẫn như vậy nên hơi lo k biết có sao k

    • @thanhsotv9019
      @thanhsotv9019 3 ปีที่แล้ว

      @@phuongnhinguyen5969 thông đáy có cái lợi là tiết diện chứa cặn bã dc nhiều hơn, cặn nó sẽ tràn sang ngăn số 2 » thời gian sử dụng dc lâu hơn cho đến khi bạn phải gọi đội hút hầm cầu tới hút.

    • @Tuan_anh_dark_hunter_99
      @Tuan_anh_dark_hunter_99 3 ปีที่แล้ว

      @@S-HOME p0

    • @tanhleg3739
      @tanhleg3739 2 ปีที่แล้ว

      @@S-HOME êêêel

  • @leductho9230
    @leductho9230 3 ปีที่แล้ว +27

    Các ống thông chữ T thông bể phản tác dụng, với nhà dân kích thước bể, đặc biệt chiều cao rất hạn chế không thể mang mấy công thức máy móc ra mà làm, xin góp ý kiến như sau:
    1. Đầu T mà cao qua màng phân thì sẽ thoát mùi qua lỗ thải ra ga.
    2. Thấp hơn mặt nước thì lúc đó nước qua ống thông có 2 hướng thu trên và dưới, quỹ đạo của dòng nước nó sẽ khác nó sẽ ra cả bã .
    3. vị trí các lỗ thông các ngăn bạn cần bố trí zic zắc, sao cho đường đi của nước trong bể sẽ có hành trình dài nhất. Hiệu suất tăng. Cao độ ống thông ngăn 1 sang 2 lấy ở dưới cách đáy 40cm với nhà dân . ngăn 2 sang 3 lấy phía trên cách mặt nước bể cõ 50 cm, Đầu phía bể 3 quay co, nối ống xuống cách đáy bể 30cm. Lúc này bể 3 có thể cho vật liệu lọc hoặc thành bể lắng 2 cũng đc. ( ống vị trí này là ống fi110, nối với 1 cút, cao độ đặt ống tính là mép dưới của co do bể nhà dân mực nước trong hồ không tiêu chuẩn)
    4. Ống thoát ra ga có mặt đáy ống cách đáy tấm đan mặt bể từ 20 đến 30cm, đầu co quay xuống 20cm để ngăn mùi ra ga.
    Nếu thực hiện đúng kỹ thuật với thể tích bể từ 300 đến 500 lít/ nười các bạn hoàn toàn yên tâm không nghĩ đến việc hút bã làm gì cho mêt.
    Chúc cả nhà vui vẻ thành công!

    • @nonguoc1510
      @nonguoc1510 2 ปีที่แล้ว +1

      chính xác theo ý kiến của mình thì lắp ống chữ t chẳng có tác dụng dụng gì cả nó còn gây thêm tác hại hơn là nó sẽ hút cả lớp màng cạn bã của phân ở bên trên khi nó chưa kịp phân hủy nó sẽ sang bể lọc thứ ngay

    • @hoangquangtrung73
      @hoangquangtrung73 ปีที่แล้ว

      cái số 1 mình thấy phía trên các ngăn có trừa lổ thông hơi thì hơi nó vẫn qua bể số 3 thôi. và nếu thay t thì nên làm bằng co 90 đục lổ hay sao . mong bạn giải đáp hoặc có bản vẽ cụ thể để mọi người tham khảo

    • @HoangTran-fe5nd
      @HoangTran-fe5nd หลายเดือนก่อน

      bạn cho mình sdt mình cần tư vấn

  •  4 ปีที่แล้ว +2

    Chia sẻ rất chi tiết . chúc bạn cuối tuần vui vẻ

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว +1

      Cám ơn bạn

  • @ExploreVancouverCanada
    @ExploreVancouverCanada 4 ปีที่แล้ว +4

    Very good knowledge and ideas because in Vietnam sewage systems are bad specifically in small cities

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว

      Thank you.

  • @AcademieCôBa
    @AcademieCôBa 4 ปีที่แล้ว +3

    Bể phốt nhiều ngăn như vày tránh phải bị đầy hút hoài, rất tiện lợi.

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว

      Cám ơn Cô

  • @LuanNguyen-wl6wi
    @LuanNguyen-wl6wi 5 หลายเดือนก่อน +1

    Tôi đã tham khảo thực tế rất nhiều tại các công trình xây dựng nhà ở riêng lẻ . Hầu hết họ đặt các cút từ bể 1 sang bể 2 . Bể 2 sang bể 2 theo chiều ngược lại như bạn đặt ( đầu ống nước ra cao nhất ) . Riêng nhà tôi làm như Bạn làm . Tôi đã góp ts kiến với họ nhưng không ai làm theo ( một mình nhà tôi làm 1 kiểu giống Bạn làm ) còn tất cả các gia đình xung quang nhà tôi họ đều làm ngược lại , ống thoát nước ở bể 3 cao nhất

  • @chanhdao3136
    @chanhdao3136 2 ปีที่แล้ว +1

    Cam on anh, anh giai thich rat ro rang.

  • @hoanghieu3358
    @hoanghieu3358 3 ปีที่แล้ว +12

    Thứ nhất ống ra lên thấp hơn ống vào 10 đên 15cm. Thứ 2 các ống thông ngăn làm chữ T như kia không tác dụng. T chỉ làm ở đầu vào để tránh bị e.

    • @minhtungvu1045
      @minhtungvu1045 2 ปีที่แล้ว

      Ong thong ngan phải lam ntn vậy bác. Xin chỉ với

  • @dongluong3642
    @dongluong3642 2 ปีที่แล้ว

    cam on anh, qua hay va rat huu ich

  • @vuhoanguyen1622
    @vuhoanguyen1622 2 ปีที่แล้ว

    Bạn để ống kích thước từ mặt thành xuống là ống với tầm mức nước là 400 và khoảng 45cũng ok vì nếu bể pot để ống thoát bể 3cao quá thì mức nước sẽ bị đựng nhiều còn tầm nước nếu để cao quá thì nhiều nước đầy ắp khi ống thoát bồn xả xuống không có thoát ly được khi xả bồn càu không có không khí ở dưới và hay có tình trạng thoát chậm và phân nhanh đầy sử dụng nhiều khi hay bị tắc nghẽn bồn càu do để mức nước ở trong bể pot quá đầy dẫn đến độ chứa pân không có thông thoáng của trên mặt phán sẽ nổi nên và đóng mảng váng hiện tượng phân khi đầy nên có thể sát nắp bể và có thể nén xuống vậy thì ống nước phi 114có co và ống ta có thể đặt thấp nữa ở ô chứa 1thì cũng tốt bạn vẽ hay quá 👍

  • @DungLe-ne3vg
    @DungLe-ne3vg 2 ปีที่แล้ว +7

    Ống dầu vào "có thể thấp hoặc cao ..."nghe tới đây đã thấy huyên thuyên rồi !Theo tôi mỗi chi tiết nằm trong tổng thể chỉ có một phương án tối ưu !!!

    • @anbuivan3702
      @anbuivan3702 2 หลายเดือนก่อน

      Nghe rất hợp lý cho đến câu này

  • @VUBAOANGlobal
    @VUBAOANGlobal 4 ปีที่แล้ว +4

    cấu tạo bể phốt rất hoàn hảo

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว

      Cám ơn bạn

    • @lenguyetnguyenthi3122
      @lenguyetnguyenthi3122 7 หลายเดือนก่อน

      ​@@S-HOMEcho mình hỏi tí được không bạn

  • @cuongcorone5913
    @cuongcorone5913 2 ปีที่แล้ว +1

    A cho e hỏi xây bằng gạch bloc có ảnh hưởng j k a và bể mới xây thì nên bơm đầy nước cả 3 ngăn hay bơm như nào thì tốt nhất ạ.thanks

  • @canhduy9548
    @canhduy9548 3 ปีที่แล้ว

    Cảm ơn anh

  • @ThaoNguyen-ze2zl
    @ThaoNguyen-ze2zl 3 ปีที่แล้ว

    Tuyệt vời

  • @thaihoang5094
    @thaihoang5094 3 ปีที่แล้ว +2

    Hướng dẫn không nên “rê chuột vi tính “ chớp nháy, chớp nháy , chuyển động liên tục nhanh quá làm cho người xem khó nắm bắt kỹ thuật làm .

  • @Duongtangsuphu
    @Duongtangsuphu หลายเดือนก่อน

    Bạn ơi đặt ống chữ T như vậy thì ống từ 1-2 sẽ bị bã vào làm tịt còn cửa thông cặn dùng một thời gian sẽ bị đầy tịt lúc đó bể phốt VÔ DỤNG

  • @HaiHoang-vt2mh
    @HaiHoang-vt2mh 3 ปีที่แล้ว +2

    2006 tôi có làm như thế này, lúc đó toàn là co đất thôi. Hầm chưa hút lần nào

  • @phapuc7088
    @phapuc7088 3 ปีที่แล้ว

    Rất hữu ích, thanks

  • @HangKhach-hn9qt
    @HangKhach-hn9qt 4 ปีที่แล้ว

    Xin hoi o noi khong co duong thoat nuoc co nen xay be tong va tham nuoc khong a cam on

  • @thinnguyen6931
    @thinnguyen6931 4 ปีที่แล้ว +1

    Rat bo ich cho n ai can tham khao .cam on ban

  • @trungnguyen9290
    @trungnguyen9290 2 ปีที่แล้ว

    A cho hỏi ống bồn cầu đặt ngay trên bể chứa một đường thẳng vậy khoản cách từ mặt nước trở lên ta có nên khoan một lỗ trên thân ống được ko a,

  • @lylytran1685
    @lylytran1685 2 ปีที่แล้ว +2

    Anh nói " Ống vào có thể đặt cao hơn hoặc thấp hơn ống ra" .Nếu ống vào mà cao hơn ống ra thì nước có chân leo từ thấp lên cao à!

  • @THIENCO-hs3dn
    @THIENCO-hs3dn 4 ปีที่แล้ว +4

    bản vẽ thì rất hay song người thuyết minh thì làm hỏng hết .Lúng ba lúng búng như ngậm hột thị thậm chí có chõ còn chua hiểu hết .Thật đáng buồn cho những người hoc không đến nơi đến chốn

  • @huuhanguyen522
    @huuhanguyen522 2 ปีที่แล้ว

    ống thông từ bể 2 sang bể 3 có cần phải đặt ống như vậy ko và đặt khoảng cách như nào

  • @THIENCO-hs3dn
    @THIENCO-hs3dn 4 ปีที่แล้ว +10

    cách đăt ống cũng sai từ bể 1 sang bể 2. bẩn vẽ quá đep song do trình độ có hạn nên làm hỏng cả

    • @cuongphan559
      @cuongphan559 3 ปีที่แล้ว

      Đặt tnao thì mới đúng b

  •  3 ปีที่แล้ว

    Bạn cho hỏi làm thế này thì tính thể tích hiệu dụng bể là tổng thể tích 3 ô ạ? Chiều cao bể muốn cao bao nhiêu cũng được ạ?Nhà 11 người thì nên để bể thể thích bao nhiêu ạ? Sau này hút bể thì hút ở lỗ nào ạ, có thể thiết kế thêm lỗ hút bể không ạ? Em cảm ơn ạ!

  • @user-kz3de9kf4m
    @user-kz3de9kf4m 9 หลายเดือนก่อน

    Đường phân vào lắp T như vậy thì sau này phân sẽ nổi ở chỗ T và sẽ bị tắc.nên dùng L thôi

  • @nguyenbatuoc9906
    @nguyenbatuoc9906 4 ปีที่แล้ว +2

    Mh chuẩn bị l As làm bể phớt .theo cách của bạn ....kỷ thuật như bạn dã huống dẫn .Thanh you ..

    • @ngocha886.2
      @ngocha886.2 4 ปีที่แล้ว +1

      Tiêu chuẩn thiết kế bể tự hoại 3 ngăn đạt chuẩn TCVN 10334:2014

  • @kkkhungk
    @kkkhungk 3 ปีที่แล้ว +1

    lẩn thẩn rồi cu ơi

  • @nguyendinhhuy9690
    @nguyendinhhuy9690 4 ปีที่แล้ว +3

    Đầu vào đặt chữ T vậy liệu khí hôi của bể phốt theo đó lên cầu xí không bạn,mong bạn trả lời giúp.. cảm ơn.

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว +2

      Nếu bạn để ý kĩ bồn cầu nào cũng có đọng nước ở đáy. Họ thiết kế như vậy để ngăn mùi, khí không tràn vào phòng vệ sinh được

    • @nguyendinhhuy9690
      @nguyendinhhuy9690 4 ปีที่แล้ว

      @@S-HOME
      👍👍👍😁

  • @khanhthunguyen4650
    @khanhthunguyen4650 2 ปีที่แล้ว

    Ban tự vấn dup mình nếu lắp bề chứa nằm trong nhà vệ sinh xã trực tiếp xuống bề chứa thì se ko co tê và lo thông hơi thi có ảnh hưởng gì về mùi hoi hay tắc khi ko ?

  • @1989s_Official
    @1989s_Official 2 ปีที่แล้ว

    Tác dụng của ống T từ bể 1 sang bể 2 để làm gì vậy b.

  • @ngocha886.2
    @ngocha886.2 4 ปีที่แล้ว +9

    Bể nước hay bể tự hoại vậy bạn?! Bạn nên nghiên cứu kỹ quy định của Bộ Xây dựng về lĩnh vực chuyên môn trước khi làm clip, đừng chỉ vì kiếm tiền mà tư vấn chưa đúng cho mọi người, khổ cho người thợ và người dân không biết và làm theo.
    Tiêu chuẩn thiết kế bể tự hoại 3 ngăn đạt chuẩn TCVN 10334:2014

    • @TrinhTran-pm4dn
      @TrinhTran-pm4dn 4 ปีที่แล้ว +1

      Không đọc tiêu đề à .đâu mà cmc ngu thế

    • @donghien5133
      @donghien5133 3 ปีที่แล้ว

      Mình cũng thấy bạn này ko hiểu gì về tự hoại mà lại đi tư vấn

    • @nhuintarnet5296
      @nhuintarnet5296 3 ปีที่แล้ว

      Bạn có tài liệu chuẩn cho mình xem với ..

  • @Dotobaclieu
    @Dotobaclieu 3 ปีที่แล้ว +1

    Ống chữ t có cần bích đầu lại không anh

  • @trongphuong15A
    @trongphuong15A 3 ปีที่แล้ว +2

    Căn cứ hình vẽ ad đặt sai cữ bể chứa và bể lắng. Vì bã nổi sẽ vào ống sang bể lắng

    • @S-HOME
      @S-HOME  3 ปีที่แล้ว +3

      Về lý thuyết thì phân sẽ nổi lên trên dần tan rã tuy nhiên trên thực tế thì phân có thể nổi, chìm, hoặc lơ lửng nó phụ thuộc vào nguồn thức ăn chúng ta ăn vào, tình trạng phân lỏng, chặt hoặc chặt vừa, vì vậy dù bạn có đặt chữ T hay cút... thì cũng không ngăn được phân sang bể 2. Thực chất nước thải có mùi hôi hay không phụ thuộc rất lớn vào nguồn vi khuẩn sống trong bể phốt hoạt động có hiệu quả hay không? Các nguyên nhân chính làm cho vi khuẩn chết: nước tẩy rửa bồn cầu, lượng ô xi nạp vào bồn sẽ làm chết vi khuẩn kị khí, các chất kháng sinh có trong người đang uống thuốc. Khi các vi khuẩn hoạt động mạnh mẽ thì bả có nằm bên bể lắng thì cũng bị phân giải thành nước hết

  • @doiphung5709
    @doiphung5709 4 ปีที่แล้ว +3

    Bể 2 ngăn. Vì từ ngăn thứ 2 họ ko thoát đi ra cống rãnh như việt nam. Mà họ thoát đến 1 khu sử lí nước thải. Đạt chuẩn mới thoát ra cống rãnh của thành phố.

  • @thuphuongnguyen407
    @thuphuongnguyen407 ปีที่แล้ว

    Bạn ơi hầm nhà mình cứ bị dội nước lại , khó xuống là sao vậy, bạn tư vấn dùm mình cách khắc phục được không

  • @phamducnguyen9721
    @phamducnguyen9721 3 ปีที่แล้ว +1

    Ae nào biết khi xây hầm thì thấp hơn cos mặt nền là bao nhiêu là tốt k vậy ae.. Mong ae nào rành xây dựng giúp đỡ mình..

  • @TonyDuyen
    @TonyDuyen 4 ปีที่แล้ว +1

    Ống nước ra ngoài bể 3 để T làm gì

  • @kietanh9167
    @kietanh9167 2 ปีที่แล้ว

    Anh cho e hoi ,minh mua Bi nguoi ta đúc sẳn về xài co dc ko anh.minh khoi xay bể phôt

  • @cuocsongvungcao5507
    @cuocsongvungcao5507 3 ปีที่แล้ว +1

    Bn cũng có ít mô phỏng dk.
    Nhưng nói thật là bn k hiểu về nguyên lý bể cho lắm.

  • @kientrucquangthang6416
    @kientrucquangthang6416 4 ปีที่แล้ว

    Lam dung ky thuat qua

  • @HanhTran-en1zs
    @HanhTran-en1zs 3 ปีที่แล้ว

    Lớp khối đất tuy theo khu vực tuy theo diện tich

  • @uckhoi2570
    @uckhoi2570 2 ปีที่แล้ว

    Ông thông hoi co nên lap Ong T Ko a

  • @ophamhung9768
    @ophamhung9768 2 ปีที่แล้ว

    Ok hơp ly

  • @DungNguyen-rh2rf
    @DungNguyen-rh2rf 4 ปีที่แล้ว +1

    A cho e hỏi.khi đặt ông thải cảm ơn video a làm rất dễ hiểu.e muốn hỏi thêm a khó lắm ông xả thì có cho đầu ông ngập xuống dưới nước ko.vì e thấy bảo để ngập nước sẽ thoát chậm

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว +1

      Đầu vào đặt T để giảm áp suất khiến nước chảy nhanh hơn rồi

    • @huantrinh6033
      @huantrinh6033 3 ปีที่แล้ว +1

      Lúc nào cũng phải cao hơn mực nước tĩnh chứ nhiều người không biết để thấp hơn lúc xã thì xuống chậm do bị cản

    • @dangcuong686
      @dangcuong686 2 ปีที่แล้ว

      @@huantrinh6033 ok

    • @cuongcorone5913
      @cuongcorone5913 2 ปีที่แล้ว

      @@S-HOME để ngập nước bao nhiêu cm là ok ạ

  • @QuynhLe-te1mn
    @QuynhLe-te1mn 2 ปีที่แล้ว

    2 cái ống ở ngăn giữa đặt thế đúng ko ad

  • @anhgio2990
    @anhgio2990 3 ปีที่แล้ว +1

    cho em hỏi bể 1 và 2 có thông cặn với nhau thì sau này đầy hút chỉ được phần cặn bể 1, cặn ở bể 2 thì làm sao hút ra a

    • @LuanNguyen-wl6wi
      @LuanNguyen-wl6wi 5 หลายเดือนก่อน

      Bạn không được thông đáy từ bể 1 sang bể 2 , vì nếu làm như vậy bể phốt chảu bạn chỉ còn 2 bể . Khi bể phốt đầy chỉ đầy Bể 1 . Bể 2 và bể 3 rất ít bã ( nhà tôi kho sửa nhà có phá bể phốt dai khi sử dụng 10 năm : bể 1 có 10 cm cặn phân

  • @thualangthi6109
    @thualangthi6109 3 ปีที่แล้ว

    Dat ong rua rang phan vo dc anh

  • @dinhnhatnguyen3034
    @dinhnhatnguyen3034 4 ปีที่แล้ว

    A cho hỏi chiều cao của các ống

  • @ChienNguyen-pm1tw
    @ChienNguyen-pm1tw 2 ปีที่แล้ว

    ngăn 3 có cần đổ đấy bê tông ko a ơi

  • @hoaibuixuan4400
    @hoaibuixuan4400 3 ปีที่แล้ว +2

    Bể nhà em cũng làm như vậy , sao nó ko rút đc anh ơi anh giải thích hộ em với ah

    • @kientrung1477
      @kientrung1477 3 ปีที่แล้ว

      Nó nừa đấy , đặt ống vào ra sai bét

  • @hhsjsj7693
    @hhsjsj7693 3 ปีที่แล้ว +1

    Bác cho hỏi nhà vệ sinh xây trên bể phốt thì bồn cầu lắp trên tấm đan bê tông vậy có cần lắp thêm ống pvc nối sâu xuống dưới mặt nước để chánh phá màng phân trên mặt nước ko. Mong bác trả lời em cảm ơn bác

    • @S-HOME
      @S-HOME  3 ปีที่แล้ว

      Vẫn phải đi ngập vào nước bể nhé

    • @cuongcorone5913
      @cuongcorone5913 2 ปีที่แล้ว

      @@S-HOME để ngập bao nhiêu cm là hợp lý ạ

  • @batueanh6798
    @batueanh6798 4 ปีที่แล้ว +1

    Thiếu ống chờ hút

  • @manhkien1675
    @manhkien1675 4 ปีที่แล้ว +1

    Cho mình hỏi ống dẫn từ nhà vệ sinh ra bể phốt hơi xa và ống dẫn bị nối và gấp có sợ bị tắc k ạ?

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว +2

      Trường hợp phải nối thì nối chếch 135 độ không nên nối cút 90 độ

  • @ngochavnhi6893
    @ngochavnhi6893 4 ปีที่แล้ว +1

    Máy móc lô dích nhưng sai bét

  • @nanghanangha6288
    @nanghanangha6288 3 ปีที่แล้ว +1

    Anh ơi mình xây bể phốt xong bơm nước vào luôn hay như nào vậy.tv giúp em với

    • @S-HOME
      @S-HOME  3 ปีที่แล้ว

      Lấy ít cây chuối cho vào bể, bơm nước ngâm 3÷4 ngày ( càng lâu càng tốt) để cho sạch nước xi măng, sau đó bơm nước ra rồi mới đậy nắp bể. Mục đích tạo môi trường thích hợp cho các vi sinh vật sau này phát triển dễ dàng

  • @LongNguyen-bv9wx
    @LongNguyen-bv9wx 4 ปีที่แล้ว +2

    Đã ko biết thì đừng nói

  • @taitri7737
    @taitri7737 3 ปีที่แล้ว +1

    A cho e hỏi. E dự ₫ịnh làm Hầm to, nhưg vì diện tích ₫ất hk có. Nên e xây hầm ₫ộ sâu ₫ến 3m, (cả 3 ngăn thì mỗi ngăn e chia ra chiều ngan 1m, chiều dài 3)... E thấy ₫ộ sâu nó hơi sâu.. Vậy thì có ổn cho việc thấm rút nứơc ₫i không ạ?

    • @S-HOME
      @S-HOME  3 ปีที่แล้ว

      Nhà dân Không nên làm sâu quá 2m nhé. Càng sâu áp lên thành bể càng lớn dễ thấm nước, nứt bể, hơn nữa đào sâu quá cũng dễ bị sập hố móng

  • @trankhanhly1508
    @trankhanhly1508 3 ปีที่แล้ว

    Bỏ lỗ thông đáy và hạ thấp cao trình lỗ từ lắng sang lọc 20cm là chuẩn bài.

  • @thaithientv3313
    @thaithientv3313 4 ปีที่แล้ว +1

    Anh cho e hỏi. Truoc khi đẩy nắp hầm. Mình có cần bơm nuoc vào truoc kg

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว

      Tốt nhất là bơm nước để kiểm tra thấm

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว

      Tốt nhất là bơm nước để kiểm tra thấm ạ

  • @LinhNguyen-xc5wx
    @LinhNguyen-xc5wx 3 ปีที่แล้ว +2

    Ông làm xây dựng mà ông cứ bảo "người ta khuyên..." . Đã làm xây dựng khi nói đến vấn đề kỹ thuật thì phải căn cứ theo các tiêu chuẩn, quy trình, quy phạm rõ ràng.

    • @hautran8319
      @hautran8319 2 ปีที่แล้ว

      ông thì hay r, tính hộ mình hệ số poison theo tiêu chuẩn nào :))

  • @viethai7183
    @viethai7183 3 ปีที่แล้ว +3

    Cho mih hỏi sao mih xem 1 số hướng dẫn khác lại nói ống T thông sang ngăn 2 và 3 phần T trên phải nhô lên trên khí mà của bạn mô hình lại nằm chìm dưới nước vậy??

    • @S-HOME
      @S-HOME  3 ปีที่แล้ว +2

      Từ ngăn 2÷3 có thể đặt T hoặc cút 90°, đều được nhé. Trong này mình để T mục đích chính là trường hợp bể đầy cặn bịt mất đầu dưới của T thì vẫn có lỗ dự phòng phía trên hay hơn là cút chỉ 1 đầu vào

    • @viethai7183
      @viethai7183 3 ปีที่แล้ว +1

      Vậy là T sag ngăn 2 và 3 chìm dưới nước sẽ ko ảnh hưởng j đúng ko ạ!! Mình cũng dang xây 1 bể phốt 7 khối 2 và đang đặt ống như hướng dẫn của ad??

    • @chuoicu4617
      @chuoicu4617 2 ปีที่แล้ว

      @@S-HOME làm cái lỗ thông nước ấy 150x150 hoặc 200x200 và đặt ở cao độ dưới mực nước 400mm

  • @duonginh1445
    @duonginh1445 4 ปีที่แล้ว +1

    Kính thước ko có. Chán chết

  • @HungYenEnglishClub
    @HungYenEnglishClub 8 หลายเดือนก่อน

    Ống vào thấp hơn ống ra thì nước chảy ngược à

  • @tinhthai7979
    @tinhthai7979 4 ปีที่แล้ว +2

    Xem kỹ thuật hơi thắc mắc, tại sao? Từ số 1 sang số 2 chừa phía dưới thông cặn qua lại, theo tôi đừng xây tấm tường ngăn , cho cặn sang 1-2 như 1, thì sao cho là lắng, ống sang dưới sang, vậy sao lắng được

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว +3

      Bản chất bể 3 ngăn mà ngăn 3 không có lớp vật liệu lọc thì cũng giống như bể 2 ngăn, tuy nhiên bể 3 ngăn thì phân có nhiều thời gian trong bể hơn , nên nước ra từ bể 3 ngăn sẽ trong hơn nước ra từ bể 2 ngăn

  • @HungTran-ne4mq
    @HungTran-ne4mq 4 ปีที่แล้ว +1

    Nhà mình bể phốt cách bồn cầu khoảng 15m, trước có thợ làm đường phân vào bể phốt là co 90 úp xuống, nước chảy ra rất chậm và lờ đờ rồi xuống không dứt khoát, phân vẫn còn trong bồn cầu, rất khó chịu, phải giật nước 2 lần mới hết. Giờ mình muốn sửa lại, bỏ cái co thành ống thẳng vào bể phốt được không bác, hay bắt buộc phải làm chữ T, mong bác phản hồi giúp mình

    • @thuynguyetothi2719
      @thuynguyetothi2719 4 ปีที่แล้ว

      thoát chậm 1 phần chính là do mất khí vì co cụp xuống. bác có thể dùng tê cong để lấy nhờ khí của bể thoát mới nhanh được. còn cẩn thận nữa trong phạm vi 15m mà xử lý được bác chích ra 1 đường thông hơi đảm bảo thoát êm ru

  • @minhdung7069
    @minhdung7069 2 ปีที่แล้ว +1

    cho hỏi tại sao khi mưa nhiều bồn cầu lai đầy nước và cách khắc phục ntn ạ

    • @nguyendan3768
      @nguyendan3768 2 ปีที่แล้ว

      Tại vì bể bị rò .ngấm nước vào trong hầm

  • @user-er6sw9yk2v
    @user-er6sw9yk2v 9 หลายเดือนก่อน +1

    A ơi cho e hỏi ống lap cho cho xí lap ông 90 đc k AK ,với lại ông thoát nước bể với ông thoát sàn có đi chung nhau 1ong đc k vậy a

    • @S-HOME
      @S-HOME  9 หลายเดือนก่อน

      Ống thoát xí và thoát sàn đi 2 ống khác nhau nhé. Ống thoát sàn không đi vào bể phốt nhé. Ống vào nên đi T là tốt nhất nhé.

    • @user-er6sw9yk2v
      @user-er6sw9yk2v 9 หลายเดือนก่อน

      @@S-HOME thoát sàn e k cho vào bể đau y e là e dân 2ống đi đc 1doan cho 2ong thành 1ong có đc k vì e dân nước thoát sàn và ông thoát be phốt xã

  • @xuanduongnguyen5302
    @xuanduongnguyen5302 4 ปีที่แล้ว +2

    Sao ko nói 3 lỗ vào , ra cụ thể cao thấp với nhau thế nào

  • @chuoicu4617
    @chuoicu4617 2 ปีที่แล้ว +3

    Cảm ơn bạn chia sẻ Video hữu ích này, và mình xin có vài ý kiến về việc thiết kế và thi công bể phốt 1 cách chính xác hơn.
    + Nếu bạn làm lỗ thông cặn giữa ngăn 1 và ngăn thì ngăn 2 sau một thời gian sử dụng sẽ bị đầy cặn trước ngăn số 1 vì sự xáo động và dịch chuyển cặn từ ngăn 1 sang.
    + Bạn phải có lỗ thăm trên các nắp đan (thường là đường kính 150 hoặc150x150 hoặc 200x200 ) cho việc hút cặn ở ngăn chứa cặn hoặc các ngăn còn lại để kiểm tra khi cần.
    + Nước từ ngăn 1 sang ngăn 2 nó có dòng hướng từ dưới lên do đó nó nên đặt ống thông ở dưới cao độ 400mm so với mực nước và ko cần chữ T như bạn vẽ. Vì chữ T như bạn vẽ ở cao độ của cặn nổi thì cặn nổi sẽ đi vào ống thông này và đọng tại đó và dần dần sẽ bị tắc.
    Mong rằng MN đóng góp thêm ý kiến

    • @dangcuong686
      @dangcuong686 2 ปีที่แล้ว

      Chuẩn đó bạn

  • @hoanthaitv9093
    @hoanthaitv9093 3 ปีที่แล้ว

    A cho em hỏi, nhà có 6 người nên xây bể kích thước bao nhiêu cho phù hợp vậy anh , cảm ơn

  • @qlee9229
    @qlee9229 3 ปีที่แล้ว

    Sai bét. Đặt T kiểu đấy mùi lại thổi ngược lên bồn cầu. Chỗ đấy chỉ Đặt cút nối.. thông hơi từ bể này qua bể khác cũng không đi thông từ 1 sang 3 thế..

    • @tuannguyentrung6522
      @tuannguyentrung6522 3 ปีที่แล้ว

      Cái lỗ thông hơi trên mặt bể kia k nhìn thấy à mà còn thổi ngược lên bồn cầu. Ngu vl

  • @duonginh1445
    @duonginh1445 4 ปีที่แล้ว +5

    Mực nước sao cao hơn cái T từ 1 sang 2 dc. Vì nước luôn chảy chỗ thấp. Nó từ dưới đã tràn qua bên kia. Sao ngập dc như hình vẽ

    • @TuanAnh-lt9ms
      @TuanAnh-lt9ms 4 ปีที่แล้ว

      Bạn để ý ống ra cuối cùng nó cao hơn ống từ 1 qua 2 và từ 2 qua 3 nên mức nước sẽ bằng nhau và thấp hơn ống cuối cùng.

    • @lamtran5629
      @lamtran5629 3 ปีที่แล้ว

      Thực ra ông này trình bày hình vẽ sai, và trình bày cũng ko đúng. Như bạn nói là đúng, cái mặt xanh đó đúng ra phải là độ dày của váng, váng này có thể ngang ông hoặc xấp xỉ cao hơn ống sang bể 2, điều này giải thích cho việc vì sao phải dùng ống hình chữ T, có độ dày 400 cao hơn lớp dày của lớp vàng kia để váng này ko thể che bít mất lổ ống. Dưới váng mới là mực nước, mức nước phải luôn thấp hơn hoặc khi xấp xỉ nó đả có thể chày vào bể 2 theo đòi hỏi nguyên lý kỷ thuật của bể phốt. Tương tự như vậy, bể 2 và bể 3 ông dẫn luôn có tỷ lệ thấp dần để nước có thể chảy sang và cuối cùng thoát ra ngoài khi đả được quá trình lọc.

  • @huuhanguyen522
    @huuhanguyen522 2 ปีที่แล้ว +2

    cho tôi hỏi tý: khoảng không từ mặt nước tĩnh đến mặt sàn bê tông là bao nhiêu, cái này rất quan trọng đấy vì lâu ngày váng sẽ dày lên và sẽ che mất ống thông hơi

    • @S-HOME
      @S-HOME  2 ปีที่แล้ว

      Từ 20-30cm là được

    • @huuhanguyen522
      @huuhanguyen522 2 ปีที่แล้ว

      cám ơn

  • @quachnghiem1246
    @quachnghiem1246 4 ปีที่แล้ว +1

    Cho em hỏi để chữ T đầu vào của bể số 1 vậy, nếu như nhiều người dùng liên tục nó có bị ngộp ko, tại vì theo em biết mới thì phân nó nổi mà

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว +4

      Khi có phân vào bể, quá trình phân hủy bắt đầu, lúc đó trên mặt nước sẽ hình thành 1 màng váng ngăn giữa nước và không khí, nếu không đặt cút hoặc T mà làm ống thẳng thì phân vào sẽ nằm trên lớp váng, quá trình phân hủy sẽ không được diễn ra, bể sẽ đầy

    • @ngocha886.2
      @ngocha886.2 4 ปีที่แล้ว

      Tiêu chuẩn thiết kế bể tự hoại 3 ngăn đạt chuẩn TCVN 10334:2014

    • @nhonnguyen2707
      @nhonnguyen2707 3 ปีที่แล้ว

      @@S-HOME ở quê bọn đi bắc thuê cho dội thẳng từ trên xuống không co cút chi cả --ống từ bể 1 sang bể 2 và từ bể 2 sang bể 3 ống nào cao hơn và cao hơn bao nhiêu là tốt anh

    • @cuongcorone5913
      @cuongcorone5913 2 ปีที่แล้ว

      @@S-HOME nên để ngập nước bao nhiêu cm thì k nói

  • @TranNguyen-do8wu
    @TranNguyen-do8wu 4 ปีที่แล้ว +2

    Xả thẳng từ mặt bê tông xuống thì đặt ống như nào ad ơi. Help gấp với ạ

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว

      Nên đi ngang đặt chữ T như trong clip sẽ tốt hơn, còn bắt buộc phải đi thẳng thì nên cho ống ngập trong mực nước tĩnh, lắp chữ T để nước chảy nhanh hơn

    • @khosihanhhoang4802
      @khosihanhhoang4802 4 ปีที่แล้ว

      @@S-HOME là bao nhiêu cm bạn?

  • @nguyencuong9262
    @nguyencuong9262 4 ปีที่แล้ว +1

    cái quan trọng là tính toán bể phốt thì không thấy nói

  • @TamPham-sg9ke
    @TamPham-sg9ke 2 ปีที่แล้ว

    Ngứa tay hay sao mà rê chuột lên tục ko để người xem quan sát về các con số và chữ trên bản vẽ đc Ko cần nghe thuyết trình Chỉ nhìn bản vẽ là hiểu

  • @khoanguyen-ww9nr
    @khoanguyen-ww9nr 4 ปีที่แล้ว

    dạ cho hỏi mình muốn đặt thêm dưới đáy cách đáy 200 đưa ra ngoài sân vườn mục đích để hút hầm phân sau nay hầm có đầy (không đục nền nhà trong vì hầm phân nhà mình ko đặt dưới toilet mà đặt trong nhà dưới cầu thang), vậy cho hỏi mình có cần đặt co ngay từ hầm đi ra không, và ống dài tầm 3,5m có hút nổi hay không. Thanks

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว +1

      3,5m hút được bình thường, nên đi chếch cho dễ hút

    • @tuanhung849
      @tuanhung849 ปีที่แล้ว

      @@S-HOME cho e hỏi thường thì ống hút hầm cầu phi bao nhiêu ak.và đặt ống chờ để hút phi bao nhiêu ak.cảm ơn a ❤️❤️

  • @baongocdang1616
    @baongocdang1616 3 ปีที่แล้ว

    Da deo biet thi dung dua len day nhe

  • @ManhTran-wh2tx
    @ManhTran-wh2tx 2 ปีที่แล้ว +1

    Anh ơi, bể phốt nhà em ống nước ra thường xuyên bị ngập dưới nước dẫn đến nước cứ chảy ngược vào ống thông hơi thì có cách nào khắc phục được không ah.

    • @S-HOME
      @S-HOME  2 ปีที่แล้ว

      Kiểm tra độ dốc cao độ giữa ống ra và rãnh thoát nước khu vực nhé

    • @ManhTran-wh2tx
      @ManhTran-wh2tx 2 ปีที่แล้ว

      Cảm ơn anh nhiều nha.

  • @PhuongNguyen-yn6zr
    @PhuongNguyen-yn6zr 2 ปีที่แล้ว +1

    Ống thải vào có cần đặt thêm tai thỏ để ngăn mùi ko anh

    • @S-HOME
      @S-HOME  2 ปีที่แล้ว

      Ống ra nên đặt xi phong ngăn mùi, hoặc hố ga ngăn mùi

  • @NhungNguyen-hu9pu
    @NhungNguyen-hu9pu 3 ปีที่แล้ว +1

    the lap dat cai cut tu be 1 sang be 2 cach lap đay la bao nhiêu thi đung tiêu chuân.

    • @S-HOME
      @S-HOME  3 ปีที่แล้ว

      Nằm giữa mực nước nhé

  • @phungthiet7485
    @phungthiet7485 ปีที่แล้ว

    Mực nước tĩnh phải ở dưới ống từ bể 1 sang 2 chứ

  • @quanglinhnguyen8913
    @quanglinhnguyen8913 2 ปีที่แล้ว

    Tư vấn giúp em với ạ. Em có để một ống chờ bên trên nắp bể phốt. Do thiết kế lại nhà vệ sinh nên em muốn để bồn cầu trực tiếp phía trên mặt của bể phốt liệu có được không ạ. Có ảnh hưởng gì không ạ

    • @LuanNguyen-wl6wi
      @LuanNguyen-wl6wi 5 หลายเดือนก่อน +1

      Được nhưng cần có ống sâu xuống dưới mặt nước của bể phổt khoảng 20 cm

    • @quanglinhnguyen8913
      @quanglinhnguyen8913 5 หลายเดือนก่อน

      @@LuanNguyen-wl6wi vâng. E cảm ơn ạ

  •  3 ปีที่แล้ว

    😍

  • @truongphungquoc4397
    @truongphungquoc4397 4 ปีที่แล้ว +1

    Cho mình hỏi nếu quên k để ống thông khí nên mái nhà thì có sao k? Và cách khắc phục như nào ah.

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว +2

      Không để ống thông hơi thì quá trình phân hủy sinh ra khí, áp suất lớn đến 1 lúc nào đó khi đi vệ sinh, giật nước, khí sẽ thoát ra ngoài làm mùi phòng vệ sinh

    • @DuongPham-ke7jx
      @DuongPham-ke7jx 4 ปีที่แล้ว +2

      Quên thì có việc đào lên mà xử lý lại , k thì sống k yên vs nó đâu kkk

    • @rungxanhtv1762
      @rungxanhtv1762 3 ปีที่แล้ว

      Có trường hợp bị nổ bể phốt đấy vì không có ống thông khí.

  • @gianghinghi569
    @gianghinghi569 2 ปีที่แล้ว

    Tui chưa thấy bạn nào chỉ măt cắt đứng cho dễ nhìn và hình dung.

  •  3 ปีที่แล้ว

    Ok

  • @duykhanhduong5941
    @duykhanhduong5941 4 ปีที่แล้ว +2

    cho mình xin hỏi , đáy của các ngăn có xây chống thấm không? cám ơn bạn

    • @S-HOME
      @S-HOME  4 ปีที่แล้ว

      Tường ngăn các bể không cần trát chống thấm, chỉ chống thấm tường bao.

  • @lenguyetnguyenthi3122
    @lenguyetnguyenthi3122 7 หลายเดือนก่อน

    Nhà mình mới xây sử dụng 1 tháng mà bốc mùi khí cay cay nồng là bị sao vậy bạn nhờ tư vấn giúp

    • @S-HOME
      @S-HOME  7 หลายเดือนก่อน

      Bể phốt thì thoát khí ra sẽ mùi hôi nhé, quan trọng bố trí ống thông hơi hợp lý để dẫn khí ra khỏi khu vực sinh hoạt để không ảnh hưởng nhé

  • @sonisat4008
    @sonisat4008 2 ปีที่แล้ว

    Sự dụng nước thải bon cây luon

  • @HoaNguyen-if1mg
    @HoaNguyen-if1mg ปีที่แล้ว

    Kéo tới keis lui chống mặt quá

  • @raintam759
    @raintam759 3 ปีที่แล้ว +1

    Ống vào đặt thẳng xuống từ tấm đan có đc k,(từ mặt sàn xuống) nông thôn thấy toàn làm vậy

    • @S-HOME
      @S-HOME  3 ปีที่แล้ว +1

      Ống đặt thẳng xuống thì nước chảy vào bể sẽ chậm hơn, và không khí trộn vào nước trong bể sẽ không tốt

    • @phat.phapnhiemmau
      @phat.phapnhiemmau 3 ปีที่แล้ว

      Được bạn nhé, ko ảnh hưởng gì mà còn xả rất thoáng là khác, bạn nên đặt ống dài từ lắp bể xuống khoảng 50cm để phân xả đi qua lớp váng phía trên vào phần nước của bể chứa nhé

  • @Namminh1212
    @Namminh1212 2 หลายเดือนก่อน +1

    Nước tắm giặt chảy vào đâu a?.trường hợp nhà ở quê

    • @S-HOME
      @S-HOME  2 หลายเดือนก่อน

      Nước tắm giặt chảy ra ngoài nhé, tuyệt đối không có chảy vào bể

    • @Namminh1212
      @Namminh1212 2 หลายเดือนก่อน

      Tại sao ống thoát từ 1 sang 2 ,phần ống trên cùng lại bằng lớp ván.như vậy thì ván lại chạy dc qua b2 hà a

  • @MrBao1983
    @MrBao1983 4 ปีที่แล้ว

    Cách trình bày hơi khó hiểu quá..

  • @manhnguyenhoang1116
    @manhnguyenhoang1116 3 ปีที่แล้ว +2

    Ống ra mà cao hơn đường vào thì hỏng.

    • @duykhanhtran9002
      @duykhanhtran9002 2 ปีที่แล้ว

      Dễ đọng lại phân trong ống vào

  • @thuphaichiecla8128
    @thuphaichiecla8128 3 ปีที่แล้ว +1

    Chỉ có là thuyết trình hướng dẫn làm bể phốt, nhưng kỷ sư gì mà nói cứ lập và lập bập, nghe thật khó hiểu !