Heat pump tumble dryer finding faults and error codes Aeg, Electrolux, John lewis, Zanussi

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 พ.ย. 2024

ความคิดเห็น • 108

  • @paulcrankshaw2712
    @paulcrankshaw2712 4 ปีที่แล้ว +10

    The videos on this channel and the content on the website really helped me to tackle investigation of my machine. I got an "E32 - Conductimetricsensing oscillation frequency too low" error code, which according to the Electrolux manual is an Electrical / Main Board fault. After finding no obvious wiring faults, I spent £160 on a new board but this didn't fix the fault. Whilst banging my head on the closed door in desperation I heard a microswitch clicking when I applied some pressure to the door. I investigated further and found that the little plastic tongue in the top of the door wasn't going far enough into the body of the machine to activate the switch. I found that extending the plastic tongue by about 2mm using a piece of tape fixed the problem!

    • @reptilel
      @reptilel 2 ปีที่แล้ว

      hi i have error 31 and 32, have very long drying time, i dont know what can i do.

    • @dannywood6842
      @dannywood6842 2 หลายเดือนก่อน

      @@reptilel Probably a bit later but for anyone reading this:
      Error 31 and 32 relate to the moisture sensor just inside the drum. Clean it with some vinegar (as it says to do in the user manual).

  • @monzarace
    @monzarace 27 วันที่ผ่านมา

    The E32 on my T86580IH is a dirty NTC sensor. Easy to unplug and clean and reinstall.
    Then you clear the error code.
    Job done.
    Remember to clean the whole machine anyway, also the heater and condenser. Just take it apart and undo the top lid. Use some mild detergent like Mucoff (pink), and spray lightly with water. Cover the compressor side with a couple of towels before spraying anything. Takes 3 hours max in total from start to reassembly done.
    Kind regards,
    Redfox.

  • @monzarace
    @monzarace 27 วันที่ผ่านมา

    How to clear error codes:
    1: Go in service mode by turning on, then press the two most right side extra buttons at the same time for a few seconds.
    2: Turn the dial to program 8.
    3: read out the code, say E32.
    4: again press the two right most extra buttons (as in going into service mode), at the same time, for a few seconds.
    5: display no changes from your error code, to E00 - which means codes are cleared.
    6: turn off and turn on machine. This will go in another test mode.
    7: turn off directly, with out anything else.
    8: next time you turn it on, it's normal operation.
    9: if you re-enter testmode, and go to test program 8, you will see E00 - no errors.
    10: job done.
    Takes ½ a minute. This works for several older AEG machines. like for example T86580IH and more.
    Kind regards,
    Redfox.

  • @jontelling
    @jontelling ปีที่แล้ว

    Thank you for the video. I knew my motor cap needed replacing (bump start test after the hum started) and this helped me get to the right place. To note, my dryer has a cap for the motor above the cap in the video, part of the white cable tray in front of the spring. Thought I'd help anyone else who has a similar dryer. :)

    • @How-to-repair
      @How-to-repair  ปีที่แล้ว

      Glad it helped you with your tumble dryer glad we could help you @jontelling this is for you th-cam.com/users/shortse432SAb2g08 please remember to subscribe as that's what keeps this channel going. Thanks 👍

  • @berjvarjabedian2207
    @berjvarjabedian2207 ปีที่แล้ว +6

    The David Attenborough of appliance repair

  • @green-crocs-fixes1520
    @green-crocs-fixes1520 2 ปีที่แล้ว

    Thanks How-2,
    this video was extremely instrumental whilst repairing a AEG LAVATHERM 59800 I was asked to have a look @. 😀😀.

    • @How-to-repair
      @How-to-repair  ปีที่แล้ว +1

      Really glad the video assisted you. We're always here to help. Have a great Christmas and a happy New Year. Thank you very much for subscribing to the channel

  • @followyoursoul498
    @followyoursoul498 12 วันที่ผ่านมา

    Excellently explained, thank you.

    • @How-to-repair
      @How-to-repair  9 วันที่ผ่านมา

      You are welcome mate! Since we work very hard in our warehouse making free video guides for you all on appliances, we always appreciate a beer, offering a choice of single or round beer. www.how-to-repair.com/help/buy-paul-a-beer/

  • @matsh9062
    @matsh9062 3 ปีที่แล้ว

    Our float / sensor (13.08 in the video) was clogged so that it constantly indicated that the machine had to be emptied.
    Needs to be cleaned once a year.
    Thanks for a helpful video!

    • @xosambbb
      @xosambbb ปีที่แล้ว

      How do you do this? What part of the machine is this please I’m having the same problem

  • @alan4178
    @alan4178 3 ปีที่แล้ว

    Hi Paul, from your video I was able to figure out either the float switch or the pump was not working, removed the pump and applied 240v, it turned so had a look at the float switch, I removed it and it all looked good so think it may have stuck down stopping the pump coming on. Cleaned out the reservoir put it back together and filled it with water as the machine was drying, it pumped the water out as the level got near the top. Hope it stays fixed. I very much appreciated your advice.

  • @davidfenollosa5715
    @davidfenollosa5715 2 ปีที่แล้ว

    Hi Paul, very informative video. Thanks a lot. It's very rare, but another test that can be done on the compressor is to measure resistance between each of the terminals, common, run, start, and the compressor chasis, to check for current leaking. Greetings from Spain.

  • @pedropiernas3616
    @pedropiernas3616 ปีที่แล้ว

    you are good and clear in your explanations: good professional

  • @tombartels6761
    @tombartels6761 3 ปีที่แล้ว

    Dear Paul, thanks for the good explanation, great help, saved a lot of money

  • @wpaulgp1
    @wpaulgp1 3 หลายเดือนก่อน +1

    Can you tell me how to get into test mode on Grundig GTN39250GCW? Many thanks

  • @asbjorn.mejlvang
    @asbjorn.mejlvang ปีที่แล้ว

    Very nicely produced video - thanks!

    • @How-to-repair
      @How-to-repair  ปีที่แล้ว

      I'm glad that you found the video useful. Please remember to subscribe to the channel as that helps us. Hope you had a good New Year
      glad we could help you @asbjorn.mejlvang this is for you th-cam.com/users/shortse432SAb2g08 please remember to subscribe as that's what keeps this channel going. Thanks 👍

  • @giedriusv833
    @giedriusv833 ปีที่แล้ว

    Hello.Nice video.I have same model.Dryer working but after ~ 40min I get error code EHO. The fan near compresor not working,i did not chek the fan but I check voltage it is not come 220V from the board.

  • @reptilel
    @reptilel 2 ปีที่แล้ว +1

    hi, i have very long drying time , all test done and have e31 and e32 errors, but everything i think working, what the problem can be?

  • @MrRichard57000
    @MrRichard57000 3 ปีที่แล้ว

    intresting,very cool info....didn t know i was subbed,but i can see why,good channel!!!!

  • @paulheyes653
    @paulheyes653 2 ปีที่แล้ว

    Great video really good breakdown. I've bought a recon heat pump dryer that's B rated, I was after an a++ one. Could I open it up and upgrade some components from a more efficient model to get to A++ or am I dreaming ?

    • @How-to-repair
      @How-to-repair  2 ปีที่แล้ว

      I'm not a great fan of heat pump dryers in my opinion they are not cost-effective. Thanks please remember to subscribe as that's is was keeps this channel going. Thanks 👍

    • @andreiportal2951
      @andreiportal2951 2 ปีที่แล้ว

      @@How-to-repair First of all thanks for finding time to share all this knowledge with us, i need your opinion on my AEG Lavatherm Exclusiv Protex, it over drying the clothes, what can be the problem? Thanks in Advance.

  • @rama.nh.flowerharb
    @rama.nh.flowerharb ปีที่แล้ว

    i have siemens heat pump dryer everything is working great but no heating what to test or replace please

  • @mikenolan7524
    @mikenolan7524 4 ปีที่แล้ว

    Thanks for your awesome videos, using these I was able to confirm the condenser pump is working fine, but water is pooling at the front of the machine. I have removed the filters and all seems clean, but water isn't passing front the front to the back to be pumped out. Any suggestions? Cheers, Mike.

  • @solarblue72
    @solarblue72 2 ปีที่แล้ว

    Hi Paul,
    I need to replace the belt on this machine, how do you gain access to fitting the belt? Do you remove the front panel or the rear panel to fit new belt?

    • @How-to-repair
      @How-to-repair  2 ปีที่แล้ว

      I would need to know the full model number to help
      Thank you for leaving a comment, I would love you to leave your opinion on our poll about manufactures building in obsolescence to appliances. th-cam.com/users/postUgkxygHomnUySd_bYjaJBdEHPO6T4dYo9Ahm
      and this is for you th-cam.com/users/shortse432SAb2g08 please remember to subscribe as that's is what keeps this channel going. Thanks 👍

    • @solarblue72
      @solarblue72 2 ปีที่แล้ว

      @@How-to-repair the model number is an AEG T96699IH heat pump dryer, similar to the one in video Paul, any help would be appreciated 👍

  • @cal87249
    @cal87249 ปีที่แล้ว

    i have a perfect care 900 electrolux heat pump dryer, i complain that heat to much and shrinkage the clothes, i called the service mo error codes founded but they changed the mother board, after that the fan was doing on and off every 2 minutes like it should be, but unfortunately only for the first cycle, in the second one the fan switched on only to 2 randomly and thn never more like before changing mother board, but now in the cooling phase last 10 minutes the fan work, but the way it still heating to much and shrink my clothes, what i can check on it?

  • @1111vip1111
    @1111vip1111 2 ปีที่แล้ว

    I have a Samsung dryer with a heat pump 9kg compressor, it takes 3 to 4 hours to dry if I put two towels after they come out of the washing machine, is this normal or is there a weakness in the dryer? The temperature of the internal drum is approximately 45 degrees Celsius, while the LG dryer reaches 90, how can I increase the drying efficiency and temperature by changing the capacitor?

  • @Lacie...___111
    @Lacie...___111 5 หลายเดือนก่อน

    I have error code E63 on C5, C6, and C7, and then error code E32 on C8, C9 and C10. I have replaced the heater element and thermostat but still have the same error codes. Can you suggest anything please

  • @reniecrosslandmusic5545
    @reniecrosslandmusic5545 5 ปีที่แล้ว +1

    I have this model and often it seems to stop before the clothes are properly dry. Does this indicate a problem with a sensor and, if so, how do I find out and clean/repair it? Thanks.

    • @hassenmohammedsaid4559
      @hassenmohammedsaid4559 4 ปีที่แล้ว

      Renie Crossland Music i have the same problem? Keep stop (switch off ) it seems finish but it doesn’t dry. Can you help me? Please

  • @julebek
    @julebek 5 ปีที่แล้ว +1

    Thanks for your nice video(s)!. A question about my 65370AH3 (somewhat simpler, no display), does it have a TEST MODE too? Any hint for entering into that mode?

    • @Antagram
      @Antagram 5 ปีที่แล้ว

      I used the method in the following video and it worked with your model. "Aeg lavaterm protex condenser dryer model number t65270ac putting into test mode and reading error" from tim 100 channel. th-cam.com/video/aysjDpZuK5c/w-d-xo.html

  • @globalste
    @globalste 8 หลายเดือนก่อน

    Is there a video for changing the belt on this machine?

    • @monzarace
      @monzarace 27 วันที่ผ่านมา

      No, but it's very easy to do:
      1: take off the top and the two sides.
      2: take off the upper screws and a few lower down of the meatal back plate itself. Some have a plastic back plate.
      3: on the right side, take off the spring that loads the belt.
      4: take out the old belt, for example by cutting it.
      5: this will loosen the back enough, so that pulling the back out a bit, you can sneak down a new belt, for example PH7 1971 on my T86580IH.
      6: once you sneaked in a new belt, and because of loosening the back panel, you will not damage the support wheels and the big felt gasket for the drum, roll the new belt over the plastic pully and under the motor axle.
      7: reinstall the spring and test machine.
      8: the belt is good on apprx. half out on the motor axle, so place the belt accordingly around the drum.
      10: job done.
      Takes ½ hour and belt is 15 euro for and original AEG.
      Kind regards,
      Redfox

  • @steveh6054
    @steveh6054 ปีที่แล้ว

    Champion 😊

  • @milano-hb6hc
    @milano-hb6hc 3 ปีที่แล้ว

    With this test all working de pomp motor fan compressor but when i start the machine de fan compressor doe nothing and also i get not water in the reservoir under de pomp is dry i wait for your reaction thanks

    • @How-to-repair
      @How-to-repair  3 ปีที่แล้ว

      this may be a sensor or it could be the start relay on the compressor you need to check if they have power

  • @Golo1949
    @Golo1949 ปีที่แล้ว

    Hi, we have a JLTDH21 that doesn't dry any more, it doesn't show any fault codes so I tried your trick of pressing the buttons to get it into test mode but it doesn't work? I have tried lots of time but I cannot get into test mode, any hints?

    • @Golo1949
      @Golo1949 ปีที่แล้ว

      BTW its been cleaned thoroughly.

  • @ΙΩΑΝΝΗΣΛΥΓΕΡΟΣ
    @ΙΩΑΝΝΗΣΛΥΓΕΡΟΣ 5 ปีที่แล้ว +1

    hi i have the same machine and the same problem.the dryer works perfectly except 2 things.a)after drying i found only 1/3 of water to the collector on a full cloth drying and b)after drying i found returned water under the filters.Normaly this area it should be dry.i think the route from the front to the pump was closed.any idea to clean this route? thank you.(the pump works correctly).

    • @mikenolan7524
      @mikenolan7524 4 ปีที่แล้ว

      I have the same problem, did you find a solution?

    • @tamtakosxxx
      @tamtakosxxx 2 ปีที่แล้ว

      Do you still have the machine? I am about to take it apart in order to clean the condenser/evaporator unit. I am confident there is so much buildup there that no water can pass through and exit out the back for it to be pumped.

    • @tamtakosxxx
      @tamtakosxxx 2 ปีที่แล้ว

      Just finished taking apart the machine and at the end the case where the condenser/evaporator are housed in the bottom. Not a fast job. A good 2 hours work to get there. Opened it up and cleaned it thoroughly. You cannot imagine the built up inside the fins and the "mud" on the bottom. All clean now. Waiting for it to dry up so I can put it back together. It will function as good as new, and dry clothes faster too. Lets see. For the record, it is impossible to clean the unit if you do not take it apart. If you ask me, there is a pretty bad design there. Lint will build up eventually and it will clog up. If there was a side door you would be able to do the job without tearing the entire machine down.

    • @randyrattan5171
      @randyrattan5171 2 ปีที่แล้ว

      @@tamtakosxxx I am having the exact same problem. It is 6 years old , so I assume the build up of lint is the problem. Just wondering if it helped to clean it out?

    • @martinfitzpatrick4703
      @martinfitzpatrick4703 9 หลายเดือนก่อน

      There maybe an internal blockage between the front and back of the machine. On mine this was the case. I took the pump housing off to discover sludge which I sucked out with a silicone tube. To check if you pour water in the front at the small water filter area you should see the rear pump housing fill up.

  • @davedebang-bang6168
    @davedebang-bang6168 6 ปีที่แล้ว

    Hi I have AEG T856801H. It’s one of the early protex models. There is water flooding out the bottom of my dryer and no water in recovery tank. My filters are immaculate and so is front of condenser. Could it just be my pump needs cleaning. It was moved recently and unfortunately laid on its back would this cause a problem Please help

  • @arpir97
    @arpir97 3 ปีที่แล้ว

    what kind of lubricant is used between the belt ruler and the rod, please

  • @colinrimmer5620
    @colinrimmer5620 6 ปีที่แล้ว

    Having problem trying to get into test mode on the John Lewis heat pump dryer you are using
    Have tried loads of times as u have shown with no joy
    JimmyR

  • @JamesHacman
    @JamesHacman 5 ปีที่แล้ว

    I'm looking to buy a heat pump dryer in the U.S. ; which make and model would you recommend???

  • @nikoslagis
    @nikoslagis 4 ปีที่แล้ว

    Hello , great videos, thank you alot for the know how. Is the front fan supposed to suck air or blow out ? Thank you in advance

    • @How-to-repair
      @How-to-repair  4 ปีที่แล้ว

      Can you do us a favour and please share this video on your timeline Facebook twitter etc .
      This will help other people who can’t get engineers out to help them.
      th-cam.com/video/rFyGAHVFUW8/w-d-xo.html&t
      facebook.com/how.to.repair.appliances/
      Stay safe

  • @sergiucaciu2286
    @sergiucaciu2286 3 ปีที่แล้ว

    Hi how can I fix the problem for same model is working 5-10min and stop ?

  • @ingejeppesen1358
    @ingejeppesen1358 2 ปีที่แล้ว

    Have a fault on out electrolux dryer. I can hear the relays clicking but the tumbler isnt turning. E5e in the display. Also e32. What tests should I perform?

    • @How-to-repair
      @How-to-repair  2 ปีที่แล้ว

      hearing the relays click does not necessarily mean it is working correctly. without having the machine in front of me I might be giving you false information. I'm sorry I'm unable to help with this one
      please remember to subscribe to the Channel as that's what keeps us going and able to make videos for you

    • @How-to-repair
      @How-to-repair  2 ปีที่แล้ว

      th-cam.com/video/7KmnizwuUEM/w-d-xo.html&t this might have helped

    • @Lacie...___111
      @Lacie...___111 5 หลายเดือนก่อน

      I have error code E63 on C5, C6, and C7, and then error code E32 on C8, C9 and C10. I have replaced the heater element and thermostat but still have the same error codes. Can you suggest anything please

  • @mfloh2484
    @mfloh2484 4 ปีที่แล้ว

    hello can replace the compressor in the Hoover dryer ?

  • @MrJbrackley
    @MrJbrackley ปีที่แล้ว

    Very useful tutorials, thank you. Our John Lewis 7Kg heat pump tumble dryer is stopping before the indicated time and not drying the clothes fully. I have cleaned the bottom matrix which was pretty clogged. I put it in test mode and the individual functions appeared to work. At C9 it shows an E32 error code. I see what that is in your list of error codes, but do not know if that is something that may be fixed by me or would require a service engineer?

    • @How-to-repair
      @How-to-repair  ปีที่แล้ว

      John Lewis heat pump tumble dryers are usually manufactured by the Electrolux group without the full model number. I am unable to point you in any direction, but if you contact us through the website I would be happy to try and assist you

  • @giuseppemagazzu4920
    @giuseppemagazzu4920 4 ปีที่แล้ว

    Excellent video thank you. What about error E73, any suggestion?

    • @How-to-repair
      @How-to-repair  4 ปีที่แล้ว

      Iam Glad we could help you.
      My Ebay Shop rover.ebay.com/rover/1/710-53481-19255-0/1?mpre=https%3A%2F%2Fwww.ebay.co.uk%2Fstr%2Fhowtorepair&campid=5338676951&toolid=20008
      If you ever need help please use our site for 24 hour response www.how-to-repair.com/help/contact-us/
      If have a question please use our site for 24 hour response www.how-to-repair.com/help/contact-us/
      Please remember to subscribe to our channel
      th-cam.com/users/Apart4u
      Remember to Shop with www.how-to-repair.com and it would help us by posting the video or
      website on your timeline. This helps us a lot and if we really helped you can
      always buy us a beer how-to-repair.com/help/buy-paul-a-beer/
      Please remember to mark us to your favourites also I would be grateful if you would
      subscribe to our channels social media as this really helps my site and keeps
      us going.
      TH-cam. th-cam.com/users/Apart4u
      Facebook. facebook.com/how.to.repair.appliances

  • @amsk2839
    @amsk2839 6 ปีที่แล้ว +1

    hello
    wat about to enter test mod in AEG LAVATHERM T56740

  • @reptilel
    @reptilel 2 ปีที่แล้ว

    can you show how clean buttom part ? how remove belt ?

  • @רוניבשרטי
    @רוניבשרטי ปีที่แล้ว

    Hi I'm replacing the motor
    And it's still don't work
    Maybe is the capacity ?

    • @How-to-repair
      @How-to-repair  ปีที่แล้ว

      If you can have a humming noise, then there's a good chance, it may be the capacitor @user-ts5ds7td1f please remember to subscribe to our channel as that really helps us th-cam.com/users/shortse432SAb2g08 Thanks, Paul 👍

  • @frurad
    @frurad 4 ปีที่แล้ว +1

    I have the European version of AEG. Unfortunately, the pipe has copper + aluminum :(

  • @bitsnbobs1969
    @bitsnbobs1969 4 ปีที่แล้ว

    hi paul can them heat pump dryers be regassed

    • @How-to-repair
      @How-to-repair  4 ปีที่แล้ว

      yes but only with right equipment
      Can you do us a favour and please share this video on your timeline Facebook twitter etc .
      This will help other people who can’t get engineers out to help them.
      th-cam.com/video/rFyGAHVFUW8/w-d-xo.html&t
      facebook.com/how.to.repair.appliances/
      Stay safe

  • @bogdandudchenko4017
    @bogdandudchenko4017 ปีที่แล้ว

    But where is heating source on this one ? I still don't get where air becomes warm

  • @engmech337
    @engmech337 3 ปีที่แล้ว

    Hi electrolux dryer showing error R32 what is the reson

  • @ab-mr6gz
    @ab-mr6gz ปีที่แล้ว

    Where’s the best uk element as I have E60 error code

  • @bonelyjibajaromero60
    @bonelyjibajaromero60 5 ปีที่แล้ว

    Hola alguien me puede ayudar mi lavadora AEG me sale EHO en la pantalla como solucionarlo ya q en mi pais no hay servicio tecnico de esa marca

  • @matt313131313
    @matt313131313 5 ปีที่แล้ว +1

    When I run the pump it doesn't completely empty the reservoir at the back. When the water gets to a bout 1cm depth the pump doesn't seem capable of pumping it up. Is this normal or do I need a new pump?

  • @wisamali1540
    @wisamali1540 5 ปีที่แล้ว

    Hello I have the AEG and the error code is EH0! ! ! HELP! ! ! ! THANKS

  • @blackpanther078
    @blackpanther078 5 ปีที่แล้ว

    I miss some information on how to change the drive-belt.
    Anyone here who have experience on how to change the trumble-belt?
    I have an Electrolux model EDH3478RDW.

  • @zvonkogudelj5785
    @zvonkogudelj5785 4 ปีที่แล้ว

    my tumble dryer doesnt show anything on displey

  • @teesrunner1498
    @teesrunner1498 5 ปีที่แล้ว

    You didn't cover the heat pump or thermal switches? I'm trying to diagnose a Bosch dryer that has lost heat. Can't work out which component provides the heat

    • @masj
      @masj 2 ปีที่แล้ว

      The compressor itself. The first radiator is the condenser and second one the evaporator. This one gets hot and warm the air, about 45-50 degrees

  • @riomaririoma2167
    @riomaririoma2167 5 ปีที่แล้ว

    My electrolux dryer died board after 5 years. Rust all around, realy poor quality.

  • @andrewszekely6547
    @andrewszekely6547 6 ปีที่แล้ว +1

    We have an AEG LAVATHERM 86590IH3 dryer. (Type TC12H6BHP). After normal operation we found lots of water under the dryer, on the floor!!!! When I opened the filter door, there were lots of water in that area. I have started investigating the pump area at the back of the machine. I have determined with a digital multimeter that the resistance of the pump was about 750 ohm. In one of the videos the repairman mentioned that according to the service manual it should be about 750 ohm. So at this moment I assume that the pump is OK....... Next I will try to check the float sensor/switch which turns on/off the pump. Am I on the right path? Has anyone ever experienced this problem before? (I have not put the machine into diagnostics mode, yet).

    • @jenskluwer-ulrich5875
      @jenskluwer-ulrich5875 6 ปีที่แล้ว +1

      I have similar problem. Pump is working and so is micro switch. In test mode i can empty the reservoir where the pump is pumping water from. But the water flow between the water filter in front and the reservoir in the back seems to be blocked so water flows too slow for the pump to be able to work effectively. I think the passages needs to be rinsed but am currently unsure how to proceed.

    • @davedebang-bang6168
      @davedebang-bang6168 6 ปีที่แล้ว

      Andrew Szekely I’ve got same issue

    • @serveloyson8831
      @serveloyson8831 6 ปีที่แล้ว +1

      To Andrew Szekely and Jens Klüwer-Ulrich
      I have the same problem. Did you find the solution for this problem?

    • @grahamf72
      @grahamf72 5 ปีที่แล้ว +1

      I have the same problem, water isn't going from the heat pump area at the front to the pump area at the back. Pump system works fine, but there seems to be a blockage between the front and the pump assembly. Did you have any luck with finding a solution.

    • @grahamfountain2218
      @grahamfountain2218 5 ปีที่แล้ว +1

      @@jenskluwer-ulrich5875 I have the same problem. Water build up at the front of the machine, and not going to the back where the pump is. The pump works fine if I pour water into that area, but water doesn't get there. Not sure how to fix this problem.

  • @kishorkerai263
    @kishorkerai263 6 ปีที่แล้ว

    Kishor

  • @Drakon9
    @Drakon9 5 ปีที่แล้ว

    Спасибо. Filter+ ixbt.photo/?id=album:63795 Capron/porolon/viskoze

  • @claeyer3866
    @claeyer3866 10 หลายเดือนก่อน

    Hi , does the compressor only work when the elektro motor is turns on ? My circuit breaker shuts off the moment when i start a program .
    When i unplug the motor , the breaker stays on , when i plug in back the motor and unplug the compressor , the breaker also stays on . I ve tried the service mode till my fingers hurt butt it won’t work with me , please help , thank you