1. CISCO WS-C4500X-32 03.09.00.E.152-5.E VSS Basic Configuration
ฝัง
- เผยแพร่เมื่อ 8 ก.ย. 2024
- community.cisc...
10G Interface, Supervisor, Same IOS, License
1. Version Check and Configuration Register
boot system bootflash:/cat4500e-universalk9.SPA.03.09.00.E.152-5.E.bin
if version is mismatch, VSS is not established
2. License must be Same Level
3. Configure VSS
#switch 1
switch virtual domain 2
switch 1 priority 110
int port-channel 250
switchport
switch virtual link 1
!interface get turned into trunk mode and nonegotiated
int range t1/31 - 32
channel-group 250 mode on
!LACP PAGP are not accepted
switch convert mode virtual
!it took almost 10 minutes
#switch 2
switch virtual domain 2
switch 2
int port-channel 251
switchport
switch virtual link 2
int range t1/31 - 32
channel-group 251 mode on
switch convert mode virtual
!it took about 1 minutes
#Caution
While Secondary boots up, if it doesn't detect Primary by VSS link, it becomes Active
When they are active-active, MAC addresses are same, so duplication happens 0008.e3ff.fc08
If Secondary becomes standby from primary, "redundancy reload shelf"
License must be same level
If IOS version is mismatch, it will also reboot like license mismatch
different by Sup720 VSS
1. switch virtual link must be Layer 2
2. switch set switch_num 1 local is not used
virtual domain must be different if VSS are in same subnet