In Cold weather, wet bulb temperature get reduced. Decreasing the wet bulb temperature lowers the outlet water temperature, but the approach is increased because of the curvature of the equilibrium line. Hence to get same approach with same heat load and range Cooling tower height will increase for low wet bulb temperature. Hope this will clarify the confusion regarding impact of wet bulb temperature. These concept will further cleared in subsequent videos on cooling Tower.
In summer , Air temp is higher so relative humidity will be lower means rate of evaporation of water will be more hence Cooling water outlet temperature will be lower even for small height cooling tower 😅but looks like contradictory through common sense
Most awaited video sir, I am following your videos for iocl interview and I am sure sir the kind of knowledge you have provided will take me and others to their destination. Lots of love sir ❤️❤️ You are a true inspiration ❤️❤️
in the timestamp of 12:24 you told that latent heat is taken by the water and temp gets reduced . but how can temp reduce if its latent heat because it involves only phase change. explain
Is phase change takes place and heat supplied for that then temperature won’t change. But if there is no heat supplied and phase change take place then remaining liquid temperature will go down.
Amazing video. Sir I have a question, you habe explained that if the temperature of water is less than the wet bulb temperature, evaporation still happens because of mass transfer gradient. But why air becomes saturated at its wet bulb temperature? Please clear my confusion.
I believe cooling tower in a petrochemical refinery is used for the Furfurol Extraction Unit dewaxing refrigeration plant? And FEU is part of the Lube refinery.
Because approach increases at low wet bulb temperature. To get same approach more height will be required. I will explain all these things in subsequent videos.
In Cold weather, wet bulb temperature get reduced. Decreasing the wet bulb temperature lowers the outlet water temperature, but the approach is increased because of the curvature of the equilibrium line. Hence to get same approach with same heat load and range Cooling tower height will increase for low wet bulb temperature. Hope this will clarify the confusion regarding impact of wet bulb temperature. These concept will further cleared in subsequent videos on cooling Tower.
Thank you sir.
In summer , Air temp is higher so relative humidity will be lower means rate of evaporation of water will be more hence Cooling water outlet temperature will be lower even for small height cooling tower 😅but looks like contradictory through common sense
From Pakistan a lot of love and respect, i have been following you since the start of your channel.
Thanks a ton
Most awaited video sir, I am following your videos for iocl interview and I am sure sir the kind of knowledge you have provided will take me and others to their destination. Lots of love sir ❤️❤️
You are a true inspiration ❤️❤️
Splendid awareness about working principle of cooling tower.
Thank you sir.
From Pakistan
waoo that was awesome concept. Thank you sir for this🙏🙏
amazing thank you sir from pakistan
Nice explanation sir aise he aur bhi videos bnate rhe
Very nice video Sandeep sir ❤
BAHUT ASSA GURU JI , SAHI POINT PAKRA JI
Thankyou so much sir...gajab concept tha ....feeling aa gayi padhke...love you sir😊😊
Sir class bhut achchi ....h cooling tower ...se related ak lecture series bna kr complete kr dijiy sir
THANKS SIR FOR CLEARING CONCEPTS OF WET BULB TEMPERATURE AND DEW POINT TEMPERATURE.
Thank sir for making a video on cooling tower on our request 🙏
Most welcome
S😊
in the timestamp of 12:24 you told that latent heat is taken by the water and temp gets reduced . but how can temp reduce if its latent heat because it involves only phase change. explain
Is phase change takes place and heat supplied for that then temperature won’t change. But if there is no heat supplied and phase change take place then remaining liquid temperature will go down.
Sir please nitrogen plant
Aur AHU par v videos banaeye
Sir, please explain about convective cooling.
Amazing video.
Sir I have a question, you habe explained that if the temperature of water is less than the wet bulb temperature, evaporation still happens because of mass transfer gradient. But why air becomes saturated at its wet bulb temperature?
Please clear my confusion.
Absolutely Nice Explanation of All Our Quaries Related to this Topic Thanks a lot !!!
Lots of love sir from BPCL kochi refinery
Thanks a ton
Sir, steady state par jo water ka temperature h usko wet bulb temperature bolenge ki air ke temperature ko?
Sir ek vlog colony ka bhi bana dijiye
Sir heat transfer ke nusselt number,prandtal number, reynold number ke baare me bhi video bna dijeye
Thanks alot sir for these videos
Thankyou sir🙌
What do you do dear???
Thank you so much sir
I believe cooling tower in a petrochemical refinery is used for the Furfurol Extraction Unit dewaxing refrigeration plant?
And FEU is part of the Lube refinery.
Lots of love and respect for you dear sir....I want to meet you sir once...❤️
Great
Natural draft or mechanical draft ,which is more effective?
Wet bulb temperature yeh bhi identify karta hai ki kitna water vapour air collect kar payega👌
Sire pipe isometric pe details video banao. Bahut confusion hota hai iske calculation me. Double rolling calculation.
Just want to see this type of explanation in college
Nice sir
Sulphate barne se kiya problem hota hain please reply
Thank you sir
Is their any relation between Relative humidity of ambient air and cooling tower evaporation loss??
Jab pani aur air ka temp same ho haya to vapor pressure bhi to same ho jayega dono mai water vapors ka
To further evaporation kaisan hoga sir ji?
Thank You Sir 😊 Please make videos on other topics too... We love to learn from you
Sir,
Then how normal household Air cooler cools air with the help of water... Request to please give clarity on it for better understanding ...
Thnx sir for making this video
It's my pleasure
Thankyou sir ji ❤❤
Very nice video sir
Thank you sir 🙏🙏🙏
Most welcome
Sir kis mausam mai cooling tower ki efficiency jayada hoti hai.....
Iske baare me batayenge aage
Sir, when we do hydro test then why venting is necessary.
Why this video have no views!!
Sir water is liquid why we are taking partial pressure at Tw
Air ka tem bhi hota hai usmai kya hai down hota hai
Pls share the name of the writer again
Treybal and McCabe
wet bulb temp. Very low why cooling tower hight is more
Because approach increases at low wet bulb temperature. To get same approach more height will be required. I will explain all these things in subsequent videos.
@@SandeepAcademy9thank you
Kudh confuse ho bhai
Thanks you Sir
Bahut hi achhe content h
Thank you sir a lot
Nice video sir ji
Thanks and welcome