Run your own SQL query directly from Rockwell PLC

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ต.ค. 2024

ความคิดเห็น • 29

  • @alexnelson1687
    @alexnelson1687 2 ปีที่แล้ว

    Thanks for this video! Do you have to use a transaction manager for this, or does the library you're using directly communicate to a SQL database due to some robust AOIs you have installed? I'm trying to communicate direct from a PLC to a DB. So far, Omron N series can do it, Keyence KV8000s can do it, but AB appears to require a transaction manager - which means I might as well just use an edge PC w/ a transaction manager built-in. For my scenario, we're trying to eliminate the edge PC by using direct PLC to DB comms, so this will knock out AB as a contender.

    • @arcautomationconsultingltd6951
      @arcautomationconsultingltd6951  2 ปีที่แล้ว +1

      Thank you Alex for your watching this video. Using the SQL Library for AB PLC I developed will eliminate the need of the middleware/software between your AB PLC and DB, its that simple. And from your brief description and if your PLC is AB then this library will do the trick. Here is my email if you would like to discuss further -younes.faraj@arc-acl.ca

  • @ebiukulath5891
    @ebiukulath5891 2 ปีที่แล้ว

    Hey Younes, these are great tips to transact data directly to/from Logix PLC and MSSQL. Would you also share the logic in at least one Add-On Instruction? Excellent work!

    • @arcautomationconsultingltd6951
      @arcautomationconsultingltd6951  2 ปีที่แล้ว

      Ebiuku, thank you for watching. Unfortunately this library is not free. If you are interested in an AOI you can purchase it.

    • @ebiukulath5891
      @ebiukulath5891 2 ปีที่แล้ว

      @@arcautomationconsultingltd6951 Thanks Younes. How much do you charge and do you accept credit or debit card payments?

    • @arcautomationconsultingltd6951
      @arcautomationconsultingltd6951  2 ปีที่แล้ว

      @@ebiukulath5891 you’re welcome. Please send email to younes.faraj@arc-acl.ca and I will send you all the details. Thanks

  • @deepkhanderia5270
    @deepkhanderia5270 2 ปีที่แล้ว +1

    Hi I want these Logic Libraries, how can i get this? I can pay but whats the method for getting this?

  • @krlosdeath666
    @krlosdeath666 8 หลายเดือนก่อน

    Hello ARC, good video and in fact I am interested in this type of solution, my only question is if it is necessary to use the AOIs that you developed or do I need something else (I have a controllogix L72s and EN2T card in my rack), if I only need the AOIs; How I can contact you?

  • @utsavtrivedi9107
    @utsavtrivedi9107 2 ปีที่แล้ว

    Studio 5000 string has 82 characters limit so sql query should be with in 82 characters. Thanks for sharing this kind of video series. May we can get in future as well.👍

    • @arcautomationconsultingltd6951
      @arcautomationconsultingltd6951  2 ปีที่แล้ว

      Thank you for watching. 82 is only the default ..you can have more characters if you would like.

  • @imrichmorvay2227
    @imrichmorvay2227 2 ปีที่แล้ว

    Is very nice i already know that just i dont know how to set up PLC logic? any help?

  • @SCADAExperts
    @SCADAExperts 2 ปีที่แล้ว

    Read write from SQL possible?

  • @petertiagunov5666
    @petertiagunov5666 3 ปีที่แล้ว

    Stored procedures support?

  • @shuaimr1538
    @shuaimr1538 3 ปีที่แล้ว +1

    Hello, can you post the source code, can you learn it?

  • @jatindersingh1229
    @jatindersingh1229 2 ปีที่แล้ว

    hello,please share sample plc logic

  • @OvershotTV
    @OvershotTV ปีที่แล้ว

    Hello ARC, how can I contact you by email? Im very interested on it.