Click to Click PLC Communication

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 ธ.ค. 2024

ความคิดเห็น • 6

  • @ACCautomation
    @ACCautomation  2 ปีที่แล้ว +1

    More information can be obtained at our website. This includes all of the links mentioned in this video.
    accautomation.ca/click-to-click-plc-communication-remote-io/
    CLICK PLCs were designed with simplicity, providing reliable control at a low cost and with little to no learning curve.
    This simplicity makes CLICK a perfect solution for small machines, home automation projects, pneumatic applications, or anywhere a simple system needs a budget-saving control solution.
    Building on the original CLICK’s simple design, the new CLICK PLUS PLCs offer the same practical control but with some surprising bells and whistles. Using the same FREE, streamlined PLC programming software as its predecessor, the CLICK PLUS PLCs provide no-headache programming combined with advanced capabilities like Wi-Fi communication and data logging.
    The Click and Click PLUS PLC series can be found at this URL:
    accautomation.ca/series/click-plc/
    Features of the new Click PLUS PLC (C2-0xCPU) include the following:
    • Micro USB
    • DHCP support
    • DNS support
    • Wi-Fi (programming and Modbus TCP)
    • Bluetooth (Wi-Fi) provisioning
    • SD Card (Data Logging)
    • Data Logger
    • Network Time Service
    • MQTT (Publish/Subscribe)
    • Required PLC Password
    • Disable Ports
    • Strong Password Support
    • Disable Ping Response
    • Encrypted Password Transfer
    We are using the Click and Click PLUS PLCs for several reasons. Here are just a few.
    - Investment is low for the hardware, and the software is free
    - Standalone PLC with built-in I/O
    - Communication ability - Ethernet Port, RS232, RS485 - support for protocols such as Modbus RTU, Modbus TCP, etc.
    - Ability to directly expand the system with various modules, including RTD and Thermocouple inputs.
    ACC Automation
    www.accautomation.ca

  • @osseo9947
    @osseo9947 2 ปีที่แล้ว +1

    I don't have a second click plc yet but this will come in handy when the time comes! Thank you!

    • @ACCautomation
      @ACCautomation  2 ปีที่แล้ว +1

      Hi Osseo,
      Thanks for the comment. It is surprisingly easy to implement this logic.
      Garry

  • @parelectricengineeringllc1816
    @parelectricengineeringllc1816 2 ปีที่แล้ว +1

    You always have great tech videos. Keep up the good work

    • @ACCautomation
      @ACCautomation  2 ปีที่แล้ว +2

      Thank you for the comment. I appreciate it.
      Garry

  • @willteachey7457
    @willteachey7457 6 หลายเดือนก่อน

    Thanks for the great video Garry.
    I'm setting up two Send and two Receive functions for bits and ints between two devices. I can Send bits (Y201-Y206) and Receive ints (DS1-DS8), but I cannot Receive bits (Y101-Y116) or Send ints (DS17-DS20). I'm getting an ErrCode of 2 from the Receive function.
    Does anyone know where to find the documentation for the Send and Receive ErrCodes?