hello, there is already icon indicator to show the abnormal status, you want the on off button to show another color when the output is cut off by abnormal status?
hello, we have the output cables link, they are not free, you can choose it or order them in other shop, as long as the cable can support the big current, it is ok
hello, you can check the manual, just press up arrow button at main page, it can switch to 12A range, press down arrow button, it will switch to 6A range
hello, the product itself already have the filter 1.we use this capacity in parallel to eliminate the other influence so that customers can also test the same result at their device 2.and it is much easier to connect the olliscope(if you do not use the capacitor, you can use shielded wire to test the signal, the result is similar)
@@rdtech9153 Ok che è già filtrato, ma per un risultato superiore, è più pratico saldare all'interno questo condensatore in polietilene sui terminali così le interferenze sono sempre meglio filtrate , giusto?
@@niwivan3793 I mean there is already fliter inside, it is just to eliminate the error from the cables you connect, you can use shielded wire to test the signal, the result is similar
I was very happy that they already answered my request to have at least 3 decimal zeros in the 6006p version (which actually comes up to 4), in this one I believed that by having 5 digits, 2 would be 2 for the whole part of the number and the rest for fractional, but again positively surprise me with a so-to-speak "flexible" mode that up to 6A has 4 digits, which makes sense because if we want to see in the consumption range in mhA it doesn't need to have many amps and after 6A to 12A with 3 digits
In practice, there's no application where you might need 3 decimals for currents over 1-2A, yet alone 4 decimals. So, I would say, the 1mA step would be absolutely sufficient for 0-6A, and then 10mA for 6-12A is totally fine. Having 0.1mA is poor marketing. The only advantage of P series is the linear stabilization at the output, nothing else.
Its nice to see the videos are getting more professional. Keep up the good work 👍💪
thank you so much for your support , if you like it , please tell this news to your friends , thank you
You need to add dual-color LED under On/Off button to signal user about OVC protection and other alarms. This is very handy.
hello, there is already icon indicator to show the abnormal status, you want the on off button to show another color when the output is cut off by abnormal status?
@@rdtech9153 yes, why not.
@@atexnik we will consider that, but it depends on the needs of the most customers and the redisign of the circuit
Прибор отличный 👍пользуюсь давно, и видосик получился замечательно
thank you very much, if you have any questions when using it, just contact us, and hope you like it and share it with your friends, have a good day👍
Как давно? RD6012P только выпустили
@@wladimiralx6699 he said our previous power supply
Great video thanks for the thorough testing with real results shown!
thank you very much
Hi and thanks for this video.
Is there still no RD6018P / RD6024P available or in planning...?
regards
hello, for now there is no plan, it is hard to make high current version with the P version standard
very well. now I'm waiting for RD6018P model.
for now we are not sure if RD6018 will have P version, please wait for our news
@@rdtech9153 Thank you that you collect users feedback and improve your products.
@@alexrider9476 thank you
ye should include 2 banana cables at least in the package, the price of the unit is fine, but the accessories are pretty expensive
hello, we have the output cables link, they are not free, you can choose it or order them in other shop, as long as the cable can support the big current, it is ok
Congratulations 👏👏
thank you very much, hope you like it and share it with your friends, have a good day👍
Yes video ⚡👍
hope you like that
你們測量時是用你們套件所附的開關電源輸入做測試?
還是自己的實驗室電源?
记不清当时用的800W还是1000W开关电源了,太久前了
如果使用良好濾波於前級,是否能有效降低Vpp
@@jessishandsome 能降低,但是性价比就不高了
你這樣測量VPP會遠大於實際值,測量時,接地的線應該使用短彈簧作為接地,而非夾子,夾子基本上就是一隻天線,收了一堆雜波。
如果是公司等級,應該備有一隻低壓差分探頭,有1X選項的,如此才能測量出實際值,不然環境干擾還是很大的。
非常感谢你的回复,你说的是对的,非常正确。但是我们没有这样做是有原因的,因为客户手里很难有这样的条件,我们尽量用一些方法让客户复现,不然客户收到很难测量出跟我们一样的数据,就会认为我们的数据是假的。
Hello how do you configure the RD6012p with with the 0-12A range? Mine is configured to 0-6A and I can't seem to find how to change it.
hello, you can check the manual, just press up arrow button at main page, it can switch to 12A range, press down arrow button, it will switch to 6A range
@@rdtech9153 Thank you for the reply! I just couldn’t find it on the manual, sorry. And I just realised you say it on the video… Thanks again.
@@lllllll396 you are welcome😀
Any plan for 6018P/6024P? Don't really need more digits on the display, but the accuracy and
hello, there is no more device in the RD series, RD6012P is the last P version
@@rdtech9153 后续会出新的细节吗
@@张浪浪-w6i RD 系列电源现在没有新的了,除非是新系列
Hey, I wonder which power supply did you use with rd6012P to present such good results?
hello, we just use a switching power supply to power on it, normally the result will not differ too much
Could you describe in detail which model did you use?
just a normal switching power supply, if your input power supply ripple is not good, add a LC filter circuit and it is ok@@fbDWAOO7
nice
thank you so much , I am glad that you liek it
if you like it , please tell this news to your friends , thank you
I own a power supply riden 6012 not "p" can I get 5 diget through the update soft wear or even 4 diget
they are 2 different products, not just add a P in the title, the hardware structure decides the accuracy
Improve the Android application for the DPS5020 model
thank you , i will tell our engineer
a cosa serve il condensatore? non era possibile introdurlo all'interno dell'alimentatore?
hello, the product itself already have the filter
1.we use this capacity in parallel to eliminate the other influence so that customers can also test the same result
at their device
2.and it is much easier to connect the olliscope(if you do not use the capacitor, you can use shielded wire to test the signal, the result is similar)
@@rdtech9153 Ok che è già filtrato, ma per un risultato superiore, è più pratico saldare all'interno questo condensatore in polietilene sui terminali così le interferenze sono sempre meglio filtrate , giusto?
@@niwivan3793 I mean there is already fliter inside, it is just to eliminate the error from the cables you connect, you can use shielded wire to test the signal, the result is similar
@@rdtech9153 ahh ok, ho capito! grazie
@@niwivan3793 you are welcome: )
I was very happy that they already answered my request to have at least 3 decimal zeros in the 6006p version (which actually comes up to 4), in this one I believed that by having 5 digits, 2 would be 2 for the whole part of the number and the rest for fractional, but again positively surprise me with a so-to-speak "flexible" mode that up to 6A has 4 digits, which makes sense because if we want to see in the consumption range in mhA it doesn't need to have many amps and after 6A to 12A with 3 digits
thank you, if you have any suggestion, just contact us
In practice, there's no application where you might need 3 decimals for currents over 1-2A, yet alone 4 decimals. So, I would say, the 1mA step would be absolutely sufficient for 0-6A, and then 10mA for 6-12A is totally fine. Having 0.1mA is poor marketing. The only advantage of P series is the linear stabilization at the output, nothing else.
@@atexnik as long as customers need that, that is a good desgin
Warum ist der Ton so schlecht?
but I check the vdieo, the audio is not that unacceptable
You shouldve done 1v 12a to be perfectly clear
for efficiency, ripple, or accurancy?
@@rdtech9153 efficiency. It would drop some more, i was thinking while watching your demonstration
@@za_ozero sorry I do not test it when making the vidoe, yes as you said, it will drop
Device is nice, video sound is awful.
we record it in the workshop, and I have try may best to eliminate the noise