why my fan coil unit not cooling? what to do if FCU not cooling?fan coil unit chilledwater flushing

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ส.ค. 2024
  • by Yashtech7 refrigeration TH-cam channel
    FCU kaam nahi kar Raha hai Kya kare?
    FCU in Hindi
    what to do if my fan coil unit not cooling properly?
    what is FCU?
    what is full from of FCU?
    why always FCU return line in top of the chilledwater coil?
    FCU stariner cleaning
    how to flush fan coil unit
    FCU HVAC system
    FCU cartridge replacement
    FCU actuator function
    FCU connection
    FCU not colling
    why fan coil unit not cooling
    FCU not cooling solution
    DRV valve in the chilled water cooling system use,cooling issue resolved in HVAC
    FCU not cooling see up how to solved in this vedio
    5star hotel guest room FCU not cooling what to do
    HVAC service FCU not cooling complete how to solve
    Bensound.com/royalty-free-music
    • HVAC system why return...
    • HVAC system why return...

ความคิดเห็น • 17

  • @SaddamKhan-wp4om
    @SaddamKhan-wp4om 11 หลายเดือนก่อน

    Excellent explain sir

  • @asadfiroz2343
    @asadfiroz2343 ปีที่แล้ว

    Kafi acha explain kiya Apne.. thanks 😊

  • @mdsafiulislam6541
    @mdsafiulislam6541 ปีที่แล้ว

    Bohat accha laga

  • @MalikJi-om5js
    @MalikJi-om5js 8 หลายเดือนก่อน

    Sir how to calculate heat load such as door windows .electrical load .mechanical load . Man as worker in side office shops etc for air conditioner design.

  • @tabrezkhan5670
    @tabrezkhan5670 หลายเดือนก่อน +1

    Ek fcu me supply temperature sahi hai and return bhi sahi hai stainer pura clean hai valve proper open hai aur jab fcu start krte hai to return coil heat ho jaata hai fir cooling nhi krta kya problem jo skta hai plz reply

    • @nikhilmishra1268
      @nikhilmishra1268 22 วันที่ผ่านมา

      manual valve band hai PIVC ka... use open kro

    • @tabrezkhan5670
      @tabrezkhan5670 22 วันที่ผ่านมา

      @@nikhilmishra1268 hn Bhai PICV valve Ka problem tha abhi Sahi hai

  • @abhiraikar
    @abhiraikar ปีที่แล้ว +1

    FCU actuator is working normal, actuator cartridge is also ok, room thermostat is ok, stariner cleaning, FCU motor is working normal,chiller supply return temperature is also normal CHILLER PLANT CWS 7°C/ CWR 12°C,Chilled water line pressure is normal in building around 2.9br as per design, supply return gate valve is open, by pass valve close, stariner clean, chilled water coil cleaning done , FCU filter also clean but still my FCU not cooling no sweating in chilled water supply line, Please assist.

    • @yashtech7997
      @yashtech7997  ปีที่แล้ว

      As per my knowledge air lock in fcu chilled water line, please remove air lock in chilld water line to draining the water and same time note the chilled water supply line temperature it should chilled automatic when proper circulation in chilled water.

  • @rajasaboor9688
    @rajasaboor9688 9 หลายเดือนก่อน

    Actuator to saply line par hota ha

  • @technicalshaheed2210
    @technicalshaheed2210 7 หลายเดือนก่อน

    Bhai FCU room me cooling nahi ker raha stainer clean kiya hoon ab kya ker na hoga actuator bhi chang ketna padega kya

  • @marshalle.s.m.5578
    @marshalle.s.m.5578 ปีที่แล้ว

    Description is in English.. the video is NOT English.

  • @DaanishAli-kk1ht
    @DaanishAli-kk1ht ปีที่แล้ว

    Can I get your contact information?

    • @yashtech7997