Great Sir Ji, Excellent effort As usual expected from you Sir. Pls make tutorial on SPM & Inverter PCB in this model with circuit diagram explanation how this circuit works.
Raaj sir namaskar 🙏🙏🙏. Sir video excellent, useful aur learning h. But sir esake spare parts v aapke paas available hote to mechanic ko chip price me best parts mil jata aur direct milne se hume v thodi profit ho jaati. Sabse important topic ye h ki parts orginal aur best components mil jata. Inverter ki parts hum bahar se hi lete h. Orginal, good quality aur price v chip aata h aur inverter se relative total available h. Thanks
Agar thodi guidelines aap hume de payenge to bahut meharbani hogi sir. Repairing lavel ki baat kar raha hu sir. Thodi bahut pcb repair ko aane lagi h. Best components available n hone se aur basic knowledge n hone par problem hoti hai.
Sir baat aisi h ki aap to pcb repair karna sikha denge, but proper components hone par hi na repair kar sakenge. Theory and practical dono jaruri hai nahi to experience kabhi v nahi ho sakta h
Sir ji Esme ki ek pcb hamare paas aai he par usme green led to blink karti he par capacitor par volt nahi ban rahe hen mans relay nahi on ho rahi he or camnucation bhi sort karke dekha he
Sir daikin cassette ac E0 error aaa raha hai jab fan mode par chelate hai ton sahi chalta hai jab cooling mode par chelate hai to error aa kar fan bad ho jata hai pcv ho jaie gi kia sir ?
sir.voltage sabhi jagah thik AA rahi par pcb on nahi hota hai jab hot gun pcb me marte hai tab on ho jata hai taisa kyo sir please explain me sir plzzzzz
Hello sir, I have Daikin 3pcb3972-31. Compressor works in heat mode but not in cooling. There is no error code. Temp sensors seem good in kohms. What else should I check? Thank you
सरजी नमस्कार सरजी मेरे पास भी सेम पीसीबी रिपेयर में आई है उसमे SMPS के सारे वोल्टेज बन रहे हैं लेकिन Ac वोल्टेज को आगे लेजाने वाली छोटी और बडी रीले पर DC 12v + नही आ रहे मैने जंपर लगा के 100 ओ 1w रजी स्टर लगा कर वोल्टेज दीऐ तो कुछ देर बाद रीले ओन हो गई और आउट डोर Dc मोटर भी स्टार्ट हो गई तो सर रीले वोल्टेज में कहा फोल्ट आ रहा है सरजी आप जरुर बताऐ सर हम आपके विडीयो सेही मैने ये पिसीबी में कोसीस की है बहोत बहोत धन्यवाद सर जी
5/24 ka yesa mudyut ata he use 4 WIYAR ate he do in 320 volt me or do WIYAR out me 15 ya 12 volt me joine karna hota he Led tv me hm us karte he or ise chhoti hoti he kit
Sir mera dikin invater ac ma pcb ma koi prob aya ha usko mne check krvaya ha to uska kharcha 10000 bola ha itna hota ha kya? Or new pcb kitne ma ati ha
Dear Brother I have same PCB for daikin and Display shwong error (H6) asper manual mention position sensor abnormal. please if you can explain the PCB intranal what is the component was problem. If explain help as.
Sir hamare liye app knowledghe ka bhandar ho apko bahut bahut dhanyawad aise hi video banaya karo sir THANKS A LOT 👏👏👏👏🙏🙏🙏🙏👍👍👍👍🌹🌹🌹🌹👌👌👌👌
Bhai javed Shaikh from Blue Star engineering mumbai aap kaa batane kaa tarika best hai
Zabardust Guru ji
Bahut din se intajar tha sir ji...... nice
Sir vary vary good video sir daikin ac maine yah fold bahout hai
great job sir you are really master
Good tiching karte hai 👍👌👌👌👌👌👌👍👍👍👍👍👍
Good explanation
Great Sir Ji, Excellent effort As usual expected from you Sir. Pls make tutorial on SPM & Inverter PCB in this model with circuit diagram explanation how this circuit works.
Excellent work sir ji
Excellent
Best man
Very Excellent I appreciate ❤️❤️
Raaj sir namaskar 🙏🙏🙏. Sir video excellent, useful aur learning h. But sir esake spare parts v aapke paas available hote to mechanic ko chip price me best parts mil jata aur direct milne se hume v thodi profit ho jaati. Sabse important topic ye h ki parts orginal aur best components mil jata. Inverter ki parts hum bahar se hi lete h. Orginal, good quality aur price v chip aata h aur inverter se relative total available h. Thanks
Agar thodi guidelines aap hume de payenge to bahut meharbani hogi sir. Repairing lavel ki baat kar raha hu sir. Thodi bahut pcb repair ko aane lagi h. Best components available n hone se aur basic knowledge n hone par problem hoti hai.
Sir baat aisi h ki aap to pcb repair karna sikha denge, but proper components hone par hi na repair kar sakenge. Theory and practical dono jaruri hai nahi to experience kabhi v nahi ho sakta h
Aapke whatsapp number me baat kar sakte h kya. Reply jab aapko time mile
Thinks very good sir
Very good knowledge...Apka Education & Experience kya hai ?
Good morning sir ji
Good afternoon Big bro
Nice video.
Explanation 💯❤️
Sir communication module pr ek video banao please🙏
Bhaai mere pass panasonic ka inviter ac ka pcb hai us ka comnication signal nahi aa raha kya ho sakta hai us ka
Nice video sir
Beautiful information.
Number bhejo bhai
@@mdibrar7430 key ho ga.
Thanks
Vv nice sir
mein indoor mein dc motor k jaga ac motor lagana chata hon .
dc motor ka false feed back circuit ko dene ka tariqa bata den
ji bilkul aap operational amplifier ic use ker sakte ho ek perfact feedback ke liye
Nice Sir
Nyc,,,, video
Good
Please communication module ka circuit explain kr dijiye
Sir Is pcb me or bhi video Banaiye...
Sir ji Esme ki ek pcb hamare paas aai he par usme green led to blink karti he par capacitor par volt nahi ban rahe hen mans relay nahi on ho rahi he or camnucation bhi sort karke dekha he
Thank you sir
Sir is pcb k switching ic maket may available nahi hoti Kia ...Jo ap nay universal switching ic use ki
Nahi big bro yaha to nahi mili
Koi ayesa bta diziye sir universal combination moudle jo sab lag jaye
Sir mujhey aap se ac k pcb repair karwani hai .bahut sari hai. Aapse kaisay con karey
Bro dc motor ka adaptor chahiye kitne ka he
9213717087
Sir mere pass b same board hi sir same complaint jaisa sdrl per 8 th pin aur ground per 0 volts arahe hi kya karu sir
Sir mere pass sem PCB hai aur use 2,3 minat baad out door band ho jata hai matlab outdoor trip ho raha hai
sir mene ca888 module 18'' led tv power suply me lagaya but nhi chali nhi chalne ki vajah kiya ho sakti hai plz reply
Module kharab ho sakta hai
Sir ji kya 12.0.12 ka transformer laga sakte hai ..
Nahi big bro
Sar g bina camunesan k autdoor ya indor pcb chlna ho to kia krna hoga
Communication jaruri hai big bro
Sir Jo apne Powor Mudul Lagaya Use hum Market se kaise kharide ge kya bolna padta hai use lene ke liye pliz reply me
SMPS module hi bolte hai big bro uc 3844 ic se bana hota hai
Sir daikin cassette ac E0 error aaa raha hai jab fan mode par chelate hai ton sahi chalta hai jab cooling mode par chelate hai to error aa kar fan bad ho jata hai pcv ho jaie gi kia sir ?
sir.voltage sabhi jagah thik AA rahi par pcb on nahi hota hai jab hot gun pcb me marte hai tab on ho jata hai taisa kyo sir please explain me sir plzzzzz
Sir drain kise kehte hai
Raza bhai, This PCB power module STRL472 pin 6 resistor -R21how much value and watt. If you explained comments box ????
Sir mujhe aapi help chaiye maine technicians se repair karne ki kosis ki thi par use hui nhi U4 error code aara h daikin inverter ac hh
Hello sir, I have Daikin 3pcb3972-31. Compressor works in heat mode but not in cooling. There is no error code. Temp sensors seem good in kohms. What else should I check? Thank you
I will make video
Sir arly on nhi ho rhi SMPS out voltage ok h
sir strl par voltage nahi a rahi
सर सारफॅ कमपेसशर इनभाईटार ए सी का चलाना मेनवाल चलाना है थोडा बताएगें सर जी
Jai hind jai bhart
Jai Hind
Sir communication module ka number dijiye
Sir combination module kharab ho jaye to kya kare dusra to milta nahi h
Repair ho jayga
@@electriclocha sir uska ek video bana kar btayega
Ok
I think multi metr PCB k uper rakh kar hum sahi voltage measure nahi kar akhte
Jab aap varying maut kar ho tn Ac / dc batayavo
सरजी नमस्कार सरजी मेरे पास भी सेम पीसीबी रिपेयर में आई है उसमे SMPS के सारे वोल्टेज बन रहे हैं लेकिन Ac वोल्टेज को आगे लेजाने वाली छोटी और बडी रीले पर DC 12v + नही आ रहे मैने जंपर लगा के 100 ओ 1w रजी स्टर लगा कर वोल्टेज दीऐ तो कुछ देर बाद रीले ओन हो गई और आउट डोर Dc मोटर भी स्टार्ट हो गई तो सर रीले वोल्टेज में कहा फोल्ट आ रहा है सरजी आप जरुर बताऐ सर हम आपके विडीयो सेही मैने ये पिसीबी में कोसीस की है बहोत बहोत धन्यवाद सर जी
Koi pcb same problem se alag to video banaynge big bro
Ok
5/24 ka yesa mudyut ata he use 4 WIYAR ate he do in 320 volt me or do WIYAR out me 15 ya 12 volt me joine karna hota he Led tv me hm us karte he or ise chhoti hoti he kit
U2 error on Daikin AC. Can you repair outdoor PCB.
Please respond in writing
Ok big bro video banaynge
Sir mera dikin invater ac ma pcb ma koi prob aya ha usko mne check krvaya ha to uska kharcha 10000 bola ha itna hota ha kya? Or new pcb kitne ma ati ha
Sir ji aap ka nambar chahiye
Kam bhi sikhate hai apne sath
00 errors in Daikin ac how to solve the problems boss
sar apka nambar milsakta hai
Good work
My chenal technical idea in dwarka🙏
Sir ji aap Ka mobile number hitho bathao na please sir
Dear Brother I have same PCB for daikin and Display shwong error (H6) asper manual mention position sensor abnormal. please if you can explain the PCB intranal what is the component was problem. If explain help as.
When we have this PCB with same problem, I will make video all about this
sar ji aap ka WhatsApp number mil jaega
9667663078
sir apka number ha
sir mera pcb supply problem aa samre bord haa
Thank you sir.
Good
Thanks sir
Good