Wiring of Reverse Forward Motor Starter
ฝัง
- เผยแพร่เมื่อ 26 ก.ย. 2024
- This video demonstrates how to make "Reverse Forward Motor Starter". This video covers both power wiring and control wiring along with testing at the end of video using motor run status. We have used 3-phase supply from the VFD output set at low frequency so that motor rotates slowly to check the direction of rotation. Hope this video serves both tutorial value along with practical approach.
We hope this video will be helpful to beginners, technicians and students who are new to automation and electrical systems.
Subscribe us so that you don't miss any tutorial.
Click below to know about "Battery Reconditioning 4 You"
www.batteryrec...
Promoted by satyaraosiddhartha
L1 L2 L3 = Supply voltage T1 T2 T3 = Load side of Contactor At least in most parts of the U.S. Good explanation of why & how your wiring things up....
Hi, I'm a beginner here. Is he showing it backwards? Shouldn't his Lines be where he alternates two phases, rather than at the T terminals?
U a one of my best lecturer's. Imple clear and precise. Wonderfully explained . Thumbs up
This video is older but one small thing, use motor reverse contractors. They have a bar inside them that crosses between contractor preventing both from ever being active at the same time creating a 3 phase short.
These videos are very productive,they teach me alot as a technician/power engineer.
Thanks
Id advise you rather to go to school than learning from this vid, already the first wire was faulty and a fire hazard.
Bro you are the best ever . thank you so much my brother .
The use of the English language in this comment section is absolutely stellar.
Super sir
Awesome Explanation man! Very easy to understand and thanks for the visual explanation
Thank you sir
Good video Mr... A thamk you all the Way from South Africa.. you okes are great with electrics..
Thank you friend
Nice
Very easy
Thank you
Good method to show practically
i try to understand the way you discuss soo far it is ok...but next time you blog...you should put label on it every wire end and put a motor control wiring diagram...
Very halful video sir 🙏🙏
Interesting should do one also showing push buttons using and auxillery contact as a latch and also as a interlock
Very clear
Simple and good explanation. Thanks my brother.
Thanks for appreciating my work.
Good job. Thank you sir
please this connection for single or 3phase motor nice video
for 3-phase motors only
Nice video,per aap hindi me video banaao to achha hoga . Schneider contactor or 14pin wala really,push button lagaake reverse forward stater control connection wearing video dekhado please.
Good job 👍
Thank you
NICE VIDEO SIR, R.B.PRADHAN CHENNAI (TAMIL NADU)
Thanks
Very nice video....can you make a video use of AC contactor main, star ,Delta starter with out timer.
THUMBS UP ,,,THIS VID IS MORE DETAILED
You took phase for switch point 1.. and you took neutral from A1 point of both contactor.. it is clear.. and what you did the long wire of contactor..
Thank you sir
Welcome
Bhai. Sab. Dhanybad
good showing easy to realise but try to fix dinrail to contactor also i like to know a t s controle system wiring iam dias from sri lanka
Another good video
How can I use DTDP toggle switch to connect the contactor instead of selector you have used.Thanks
Sir u r super
clear cut video
and
But i have a one another doubt that is
Q: what is small connetors imean i saw on contactor small aditional connectors what is the use
Contactor do have Normally open contact and normally closed contacts, also called as NO and NC contacts.
When contactor is switched On, NO contact gets shorted and NC contact gets open circuit.
These contacts are used in control wiring.
Verry good
Nice video, I just wanted to know which motor you use i just want same setup and bought everything which you showed in this video only motor have to choose..please guide
Motor should be 3-phase induction motor. Motor current rating should be less than contactor current rating.
Suppose motor current rating is 3 Amps. Then for Direct online starting, contactor current capacity should be 6 times. So, 6x3 = 18A.
So select contactor of 18A or 25A current rating.
good job tank you
Nice
1 is connect to pase suply. but you don't show it us
Nice work
Nice one
interlocking krna jaruri tha bro... agr contector chipk geya toh three phase flash mare ga.
You are right but the MCB used at input supply will take care of short circuit protection
Good explanation sir tq
thank you sir good explaination
very nice please termination crimping the luges praperli
Of course. We should use proper lugs along with crimping tools to fix it.
Good explanation
Elhamdulilah
Very good video
Thanks for appreciation
ببینید تو کنتاکتور اول سیم زرد تو کانکت 2بسته تو کنتاکتور بعدی تو3بسته جای دوتا فاز تغییر بدی موتور برعکس میچرخه
Very helpful. .Thanks
Thanks for this video
Very nice sar mujhko penal ki or jankari .
Thank u sir,use full vidio,
i want same motor,
motor rpm, hp what sir ,
give me reply sir
Good one there bro.thanks
Thanks for appreciation
Super sir . I need to connection of conveyer with use of reverse and forward medium. Speed
Di tambah pakai timer bang, biar jalan bolak balik sendiri🙏🙏
very so nice
High quality nice
Thanks nice vid
Good that you liked it
What's this black wires connect a switch?
Can the same be used for 3-phase linear induction motor?
phase nikala kaha say liya main cable say nikal gaya a1 say , R F mi lag gayi tar magr 1 or 2 point smj ni aya q kay cam wrong direction mi tha
Automatic limit switch use reverse forward motor
Sir u r not gave a input connection in l1,l2,l3 but that connected to output side (reversed) & a1 gave to neutral instead of phase..
V nice
Thanks
plz provide names of the components used in this circuit
Sir pl 4 moter ready one by one star connector connection and three phase thanks
Thank u bro
Overload relay?
Sometimes a possibility of stuck the contactor due to mechanical problems. In this method no interlock is provided to avoid phase to phase short circuit in such case. Add one NC contact and take coil supply through it, ie the supply to F is in series with the NC of R and vice versa.
Yes. NC contact of Rev Contactor in series with Fwd Contactor coil and similarly NC contact of Fwd contactor in series with Rev Contactor coil is required for electrical interlock.
@@starautomation One more disadvantage is there. No protection is provided for the motor. Two expensive contactors are used. An overload relay and 3 push button is required for this. I think the conventional circuit is better than this.
Please attach drawing along with this.
سیم ابی و زرد از بالا کنتاکتور جاشون عوض شده
Sir diagram ke sath video karenge Tao Acha hota plz sir
Thanks🙏🙇 sr
nice
نول مستقیم به سیم پیچ هر کنتاکتور میدیم بعد فاز از کلید میگیریم و به دوتا کنتاکتور میدیم
Sir apne selector switch ka 1terminal kha connection kiya
Can I use 50 Hp motor in this circuit?
In this circuit, power contactor is not suitable for 50hp.
You should take contactor suitable for 50hp DOL starting. Use DOL selection chart to find current rating of contactor and MCB/MCCB
Ager hmm motor ki rating ki according mccb/mcb aur contector lgay to koi problem to nhii hogi
How the contecter works
این کلید به سیم پیچ خو کنتاکتور فرمان میده
Please sir more information
I shall something to do
Sir without contactor me reseve nahi hoga.. reply me
To change rotation of motor, we need to change phase sequence.
Both contractors have opposite phase sequence.
Other way of doing this will be to use Variable frequency drive. In this case, Contactors will not be required.
You have not done safety interlocking of contactor
Awedesh ji i need a small help for reverse forward motor can u pls ping me on 8123428119
Please do not use method of connection in your system as this system has no safety. Beware of electrical hazard to your systems. If your need correct wiring please send me a request.
Dear friend, this video is just to explain the concept of reverse forward starters.
However for your kind info, we are manufacturer of electrical Panels and automation systems. Our company name is Star Automation. We have completed more than 500 projects in last 15 years.
@@starautomation the title is misleading then
Mast banaya hai Lekin hindi mai banao
Singal phase motor reverse forward kese kare
thank at least i have learn some thing
Easy is just change the line
Mnx 25 and havells timer fitting wire fitting
diagram for DC motor ?
داره مدار چپ گرد راست گرد میبنده
پایین کنتاکتور ها به موتور متصل میشه برا همین به هم وصل میکنه جابه جا نمیکنه دیگه چون از بالا جابه جا کرده
Yup that first wire is already faulty.
Pura video dikh bhi nahi raha..
Formation en françai svp
Change over shoes holiday Balotra
Sir Hindi me video banoao
Where is the "point 1 for the switch" connected to?
To any live phase out put of main contactor
👍
All electrical panel knowledge hindi 👉 electric gyan center
🥀🤔
Yes good sir but please speak in hindi