Hilaw O Mahinang Lamig Ng Aircon Baka Isa Ito Sa Dahilan

แชร์
ฝัง
  • เผยแพร่เมื่อ 12 พ.ค. 2021
  • Thanks for Watching... Like Share Comment And Subscribes...
    Paki Support Po Si ‪@kejshachannel6326‬
    Please Follow on my Facebook Page
    ‪@KenKejAutoElecTrix‬
    Ginawa ko itong video na ito para ipakita na hindi lahat pag sinabing mahina o hilaw ang lamig kulang agad sa refrigerant or freon
    Hindi lahat expansion valve agad ang sira
    Dapat maging mapanuri din tayo sa ating ginagawa at huwag agad hatulan ng kung ano-anu ang papalitan.
  • ยานยนต์และพาหนะ

ความคิดเห็น • 336

  • @KenKejAutoElecTrix
    @KenKejAutoElecTrix  3 ปีที่แล้ว +20

    Ginawa ko try and error itong video na ito para ipakita na hindi lahat pag sinabing mahina o hilaw ang lamig kulang agad sa refrigerant or freon
    Hindi lahat expansion valve agad ang sira
    Dapat maging mapanuri din tayo sa ating ginagawa at huwag agad hatulan ng kung ano-anu ang papalitan.

    • @fernandocalayo5357
      @fernandocalayo5357 9 หลายเดือนก่อน

      Bakit sir yung sa low ko malamig nman masyado ang mg tubo pero pag pagpsok sa sasakyan di nmnan masyado malamig..anu kya kailangan ayusin

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  9 หลายเดือนก่อน

      Check nyo po expansion valve

    • @alexandermonte9529
      @alexandermonte9529 7 หลายเดือนก่อน +1

      Expansion valve, dapat calebrated, hnd un hula hula lang

  • @nelsondelossantos5162
    @nelsondelossantos5162 3 ปีที่แล้ว

    thanks dami ko napulot nice mga idea.salamat vlog mo sir.

  • @mangatong2775
    @mangatong2775 ปีที่แล้ว

    Yan talaga ang dapat...yung iba kc Agad nagasasabi ng kung anunu na lang..na experienced ko na kc...salamat bro..

  • @thebordsfishingtv8031
    @thebordsfishingtv8031 3 ปีที่แล้ว

    Nice video sir..dami ko nalalaman..

  • @elmerchan8621
    @elmerchan8621 2 ปีที่แล้ว +2

    galing mo sir .. ingat

  • @redenvillena6311
    @redenvillena6311 2 ปีที่แล้ว +7

    Sir advice ko lang kpag nag gagawa kayo ingatan nyo yung pintura ng sasakyan. Napansin ko yung manifold gauge nyo tumatama sa fender malamang gasgas na yung pintura, lagyan nyo po ng sapin. Ganun pa man salamat po sa share nyo

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Salamat sa concern mo sir.

    • @cletotaduran6718
      @cletotaduran6718 3 หลายเดือนก่อน

      Ha ha ha ha doble karga refrigerant

    • @jorgerecio5537
      @jorgerecio5537 4 วันที่ผ่านมา

      Kadalasan ganyan ang mga gumagawa......walang ingat sa ginagawa nla, concern lng nla ung sira ng pinapagawa pero ung masisira nla wala clang pakialam....haha

  • @balberojoelchannel1054
    @balberojoelchannel1054 5 หลายเดือนก่อน

    Galing mo ser

  • @romeicernadura5671
    @romeicernadura5671 3 ปีที่แล้ว

    sir/master sana po may lecture kayu..gusto ko din po ksi matuto ng caraircon,baguhan pa lng po ksi ako .salamat po sir godbless🙏🙏🙏

  • @kennethcamilotes7694
    @kennethcamilotes7694 3 ปีที่แล้ว

    TAMSAK DONE MASTER KENKEJ👍👍👍👍

  • @rainierl.morales7649
    @rainierl.morales7649 2 ปีที่แล้ว +7

    Sir... Hindi po sa nag mamarunong ..mali po na mag charge ng liquid refrigerant sa low side kasi yung low side is low Pressure gas bali yung suction ng compressor is low pressure gas ..
    Yung gas po is compressible.. Kung maglagay ka ng liquid refrigerant sa low side maaring magkaroon ng pag kasira ng compressor kasi yung kinocompress niya is liquid .
    Which bad sa compressor. ...
    Liquid is not compressible

  • @terioalvez1618
    @terioalvez1618 2 หลายเดือนก่อน +1

    High side dapat nasa 170 or 200,psi.pero malamig naman,walang problema sa compressor..

  • @moisesmagdadaro3520
    @moisesmagdadaro3520 3 ปีที่แล้ว +5

    Expansion valve yan bossing yan ang tinatawag open valve problem.

  • @precilogarcia8910
    @precilogarcia8910 3 ปีที่แล้ว +1

    Pag nag charge ng refrigerant sa low side gas or vapor dapat nakatayo ang tangke, pero it's up to you kung saan ka sanay. Keep up the good works kabayan.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Nasanay na ako sir na liquid ang nilalagay ko sa low side. Pansin ko kasi iba ang lamig pagnakataob ang tangke or liquid agad ang pumapasok sa low side. Stay safe po sir

    • @hectoranonuevo5001
      @hectoranonuevo5001 3 ปีที่แล้ว +2

      Kc un ibang ac tech tinitipid ang freon lalo kung magpapadagdag lng ng freon. Sistema tawag doon 😁

    • @KatreaKairisWorld
      @KatreaKairisWorld 2 ปีที่แล้ว +2

      Di tinitipid yun kasi nagbabase sa gauge reading kung hanggang san lang dapat ang pressures ng low at high side. Unang una mali ang magpadagdag. Dapat ay evacuate system and replenishnent. Proper way ng karga ay liquid pag patay makina. Then Pag buhay at pag mag dagdag vapor dapat. Kaya ung iba liquid lagi nilalagay kasi mabilis matapos magkarga Cons nyan prone sa damage ang compressor pag bigla yan nagclog dahil sa impurities ng refrigerant.

    • @melvinpadulla1712
      @melvinpadulla1712 2 ปีที่แล้ว

      @@KatreaKairisWorld ito ang tama hindi man masira agad kalaunan yan pag sigi karga ng liquid sa suction.tanda nyo mga boss hindi na kukumpress ang liquid.

  • @EdwinMillano
    @EdwinMillano ปีที่แล้ว +1

    The best flashing is the best.

  • @chanpogi4279
    @chanpogi4279 2 ปีที่แล้ว

    Sir good day.. Sir maari dn po ba n expasion valve ang sira kpg malamig ang tubo s labas at ngmomoist tpus s loob mhina ang buga.. Kelanga i number 2 minsan number 3 pa para lumamig.. Ska pag nkahinto nwawala ung lamig.. Slamat po agad.. Godbless sir more videos and tips

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Check cabin filter sir baka barado na. O kaya baka fins ng evaporator barado kaya mahina ang buga ng hangin

  • @3dlottobukidnon793
    @3dlottobukidnon793 2 หลายเดือนก่อน

    Ganyan din sa akin...sabi ngshop loscom ndaw ang compressor....

  • @ramilperez5330
    @ramilperez5330 2 ปีที่แล้ว

    Bro try mo palitan ng valve at drier plushing mo

  • @mcjoelbaldomar2994
    @mcjoelbaldomar2994 2 ปีที่แล้ว +1

    Medyo nakakairita yung video boss hahahah panay punas sa guage🤣✌️
    Pero educated naman boss👌

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Para makita mo ng ayos boss kaya lagi ko pinupunasan

  • @summerpctablet1358
    @summerpctablet1358 ปีที่แล้ว +1

    yup

  • @arvinlagmaygrageda9299
    @arvinlagmaygrageda9299 3 ปีที่แล้ว +2

    Barado ang drier filter/mahina na compressor/may air elements ang systems.

  • @josephcarloestillore8219
    @josephcarloestillore8219 ปีที่แล้ว +1

    Sir, very informative ng videos nyo. Tanong ko lang po. Nabutasan po kc ako ng evaporator, nung pinalitan. Sobrang lamig naman po, kumakagat sa balat. Pero pag Number 1-2Fan na hihilaw, pag nilagay po ulit sa 3-4 lalamig po ulit ng husto, pero diko po nakikita na nag o automatic ng Compressor sa idle. Ano po kaya possible na problema. Thank you 🙏

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว +1

      Baka po napupuno na ng ice ang evaporator pagnaka 1-2 speed kaya hilaw na ang lamig kasi hindi na nakakatagos ang hangin, pagcheck nyo po nalang po ac thermostat.

  • @noelflores497
    @noelflores497 ปีที่แล้ว

    Deffective thermostatic expansion valve,

  • @terioalvez1618
    @terioalvez1618 2 หลายเดือนก่อน +1

    Seguro compressor dapat nasa mga 35 or 49 psi.170 or 200psi.

  • @richardeugenio4080
    @richardeugenio4080 3 ปีที่แล้ว

    compressor yan sabayan palit n nung filter n prang spansion valve.. or sobra s karaga.. mahirap basahin tlaga pg GMC

  • @neridimabuyu1580
    @neridimabuyu1580 3 หลายเดือนก่อน +1

    Sir paki ayos naman ang pag explain mo sa refrigerant cycle.

  • @ronaldmonares6308
    @ronaldmonares6308 3 ปีที่แล้ว +1

    Galing boss idle. Standard n mga parameters po paki sagot nman po tanx

  • @oscarlagare8534
    @oscarlagare8534 ปีที่แล้ว +1

    Liquid sa high side n gas sa low side ang charging

  • @leiladaquil6587
    @leiladaquil6587 2 ปีที่แล้ว +2

    it is replaced every 3 years depending on model,txv expiration!

  • @tyronedeleon9348
    @tyronedeleon9348 3 ปีที่แล้ว +2

    Hello po sir, magtanong lang po ako, yung gauge reading ng aircon ng kotse ko ay 40 low side at 150 high side, dual aircon po, pero pansin ko hindi masyadong malamig yung aircon sa likod. Innova po pala kotse ko, nagpalit nga po pala ng expansion valve sa likod pero ang ginamit pang altis, sabi ng gumawa parehas lang daw kasi fit naman sa evap. Tama po ba iyon?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Kung fit sa housing wlang problema sir. Ayon sa reading sir kulang pa ang charge ng freon. Yong 40psi po na pressure sa low side normal lang po yon lalo kung ang speed ng blower sa loob naka highspeed. Yong sa highside na 150psi dapat paabot sa pagitan ng 180 to 250 psi

  • @edtech716
    @edtech716 ปีที่แล้ว +1

    pinaka acurate boss kilohin mo refregerant

  • @ranulfosayson3554
    @ranulfosayson3554 2 ปีที่แล้ว +1

    Check ang blower kung gumagana ba lahat na motor sa fun

  • @joeypadyak811
    @joeypadyak811 3 ปีที่แล้ว

    ang pagkakaalam ko sir. Gas lang dapat

  • @jericlee1509
    @jericlee1509 2 ปีที่แล้ว

    honda crv 98, unang complain ko bilis cut off compressor lamig niya 9.5 degree celcius to 11 celcius nag lalaro... di ma achieve super lamig na tagos balat. mga 30 secs on compressor and interval. reading niya 30 low side/ 170 high side. bagong palit compressor, ang old stock nalang condenser n thermisistor sensor... , baka may ma suggest kayo sir?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Ang nakikita ko lang problema sir mabilis cut off ng compressor. Check nalang kung ilang ang reading sa manifold gauge pagnaka full ang ac blower. Pag 35 to 40 low, 180 to 220 high side ok ang karga ng refrigerant.

  • @ariemayvalentosreyes4277
    @ariemayvalentosreyes4277 9 หลายเดือนก่อน

    liquid dapT para buo lamig n papasok kc dadaan sa filter dry yan mgging gas ndn sya kung gas ichacharge wlang lamig un😊

  • @cardomekanico
    @cardomekanico 3 ปีที่แล้ว

    Shoot out naman Sir cardo mekanico ytc.thanks

  • @markgilbagaporo593
    @markgilbagaporo593 ปีที่แล้ว +1

    Sir ask ko lang po..ung sakin po kanina umabot ng 50 psi ung lowside tas mga 20 mins bumaba na sya sa 36 psi lowside..mahina na po ba ang bomba ng compressor ko ,kahit kakapalit ko lang one month ago..salamat po sa sagot.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      Napapansin ko sa ganyang reading sir sa mga Toyota mataas sa una tapos unti unting bumababa.

  • @surak24
    @surak24 ปีที่แล้ว

    Napanood ko lang video alam ko na agad na expansion valve.

  • @jecxsonkinkito6967
    @jecxsonkinkito6967 ปีที่แล้ว +1

    Change expansion valve

  • @elsrick0432
    @elsrick0432 2 หลายเดือนก่อน +1

    tingin ko po overcharged😊

    • @elsrick0432
      @elsrick0432 2 หลายเดือนก่อน

      pansin ko po yan sa monte namin, nung 1st time ko mag DIY ni observed ko after karga ng refrigerant, pag #4 na speed ng fan - ayaw na mag automatic yong compressor yon pala overcharged😊

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 หลายเดือนก่อน

      Tama ka po sir overcharge at barado strainer sa likod

  • @cletotaduran6718
    @cletotaduran6718 3 หลายเดือนก่อน +1

    Normal pressure ay 30 yo 40

  • @tyronedeleon9348
    @tyronedeleon9348 3 ปีที่แล้ว +1

    Pinacheck ko sir compressor mahina na po kasi tumataas sa 50 psi low side. Ask ko lang po ang sanden compressor scroll type na rerepair ba? Meron po kasi ako extra na compressor na similar na model, ang nasira lang po doon yung pully or neck.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Ang loob po kasi ng screw type na compressor kung nakita nyo po yong bala ng barena yong drill bit ganun po ang loob kaya hindi po sya narerepair

    • @tyronedeleon9348
      @tyronedeleon9348 3 ปีที่แล้ว +1

      Balak ko po sana kahuyin yung internal parts ng reserba ko na compressor at ilipat sa nakakabit sa kotse ko, baka kako gumanda ang compression.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Subukan nyo po sir umobra maaring try and error, alam nyo po kung bkit kasi my pressure ang compressor maaring paghindi maganda ang spacer sa cover ng compressor maaring sumingaw. At pagnagtama ang oil seal sisingaw din po. Pero try nyo rin po sir.

    • @tyronedeleon9348
      @tyronedeleon9348 3 ปีที่แล้ว

      Tama po kayo trial and error na lang. Salamat po.

  • @FelixQuerijero
    @FelixQuerijero 4 หลายเดือนก่อน +1

    Hindi naman bastabasta pinapalitan ang expansion valve. Madaling nalilinis naman ang bara nyn.

  • @efrenventura6292
    @efrenventura6292 3 ปีที่แล้ว +2

    Pagkakaalam ko idol, pag may orifice n, wla n expansion valve. Cguro filter lng ung nagbara s linya. Correct me if im wrong✌ slamat😊

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว +1

      Tama po kayo boss akala ko rin nga orifice sya, nung natanggal yong kumapit na putik, filter lang pala sya.

  • @melvinpadulla1712
    @melvinpadulla1712 2 ปีที่แล้ว +1

    Boss Nasubukan mo naba na magkarga ng vapor?kasi ang tama dapat vapor pag nagkarga kasi pag liquid masisira ang compressor.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Ganun po ba sir madaling masira ang compressor, kung gnun marami na pala akong nasirang compressor kasi puro liquid kinakarga ko.

    • @noelserada8118
      @noelserada8118 2 ปีที่แล้ว

      ok lang yan kahit liquid sa low side.

  • @francesgaspe9633
    @francesgaspe9633 2 ปีที่แล้ว

    Hi sir, pwedeng magtanong regarding sa ac namin sa bahay window type sya. Mula ng mapalinisan ko humina na ang lamig nagyeyelo na at hindi na pumipitik ang thermostat, ano po ba ang posibleng mga dahilan? Salamat po sana masagot

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Maaring thermostat po hindi nag automatic cut off o kaya kulang sa refrigerant

    • @francesgaspe9633
      @francesgaspe9633 2 ปีที่แล้ว

      @@KenKejAutoElecTrix hi po sir papaanong di nag aautomatic cut off po? May mga times naman po na pag inopen nagki click at tumutunog ang compressor, pero may mga times din po na kapag inopen na po ang thermostat hindi nagkiclick kaya ginagawa po namin nakababa lang sa zero pag madaling araw po na mainit na ang buga at inopen na po ang thermostat dun po sya nagkiclick at tutunog ang thermostat at dun palang sya lalamig

  • @tyronedeleon9348
    @tyronedeleon9348 3 ปีที่แล้ว

    Sir yung blower ko no.1 lang and setting ng thermostat nasa gitna, pero hindi sya nag-automatic kapag nakapark or idle ako. Kapag nagdagdag ng freon para umabot sa 180 to 200 psi, yung low side dapat nasa 40 psi lang? paano po kung tumaas sa 45 to 50 psi ok lang po?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว +1

      Pag umabot ng 45 to 50 psi sir na kahit naka #1 ang speed ng blower medyo may tama po ang compressor o kya mahina ang cooling sa condenser. Kasi kung ganyan naka #1 ang blower dapat baba din ang pressure sa low side kung good ang compressor. Aabot ng 35 to 30 psi at maramdaman mo yong lamig na nangangagat sa balat.

    • @raulramos1057
      @raulramos1057 ปีที่แล้ว

      Sir goodafternoon, fx po sasakyan ko dual condenser na bago drier, exp valve, bago evap, 500 psi ang bomba malamig ang tubo pero sa loob hilaw/mahina ang lamig ano kaya blema sir

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      @Raul Ramos baka defective po yong bagong expansion valve. May heater pa po yang unit ninyo? Kung meron subukan nyo po condemn muna. Pero duda po ako sa defective expansion valve po yan.

  • @jeunessemenoto1243
    @jeunessemenoto1243 2 ปีที่แล้ว +1

    Over charge na refrigerant cnt boil.

  • @josephduyanen6630
    @josephduyanen6630 2 ปีที่แล้ว +1

    Check mo expansion valve

  • @user-tk2ln8mf5s
    @user-tk2ln8mf5s 2 หลายเดือนก่อน +1

    IPA calibrate mo expansion valve baka sakal....dual yan dapat more or less 40 psi yan!

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 หลายเดือนก่อน

      Hindi ako marunong mag calibrate boss

  • @bnielbalde7217
    @bnielbalde7217 2 ปีที่แล้ว +1

    Bossing..ma gandang umaga sayo..patulong naman kng anung problima ng nissan frontier qo..bago linis at bagong palit yong exponsion valve at filter dryer..pero kahit anung karga qo di tumatas yong low side hanggang 25psi lng yong hi side 120 psi anu kaya dahilang problima nya ..kasi pag malayo ang biyahi ng hihina ang lamig..salamat

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Baka naman po wala ng laman yong tanke ng refrigerant na pang refill mo kaya hindi tumataas ang pressure kasi wala ng refrigerant na pumapasok.

    • @bnielbalde7217
      @bnielbalde7217 2 ปีที่แล้ว

      @@KenKejAutoElecTrix meron naman laman yong tangke

  • @Riott245
    @Riott245 2 ปีที่แล้ว +1

    Sir ano dapat clearance ng clutch hub?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Hindi ko alam ang exact sukat sir kung ilang mm ang clearance ng clutch hub sa pulley

  • @edwinlumasag9530
    @edwinlumasag9530 2 ปีที่แล้ว

    Boss, baka walang suction Yan.

  • @rickyjayaugusto1284
    @rickyjayaugusto1284 2 ปีที่แล้ว

    Boss pano kong ung reading eh ung kulay blue eh 40 sakto
    Ung kulay pula nman ay 150, kailangan b dagdagan ang freon ng ganyang reading? Salamat po sa tugon mu

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Sakto lang reading sa manifold gauge sir. Sa 40 sa blue malamang nakafull yong blower nito kaya umabot ng 40psi, try mo lagay sa kalahati ang blower kung baba ng 35psi ang nasa blue. Para sa akin sakto lang pero check mo rin ang lamig kung hindi hilaw.

    • @rickyjayaugusto1284
      @rickyjayaugusto1284 2 ปีที่แล้ว

      @@KenKejAutoElecTrix salamat sir

  • @georgiebango
    @georgiebango 2 ปีที่แล้ว

    Me ganyn din po ba ang innova 2008? Hilaw ang aircon basta tanghali tapat

  • @joysimvictoria3647
    @joysimvictoria3647 ปีที่แล้ว +1

    filter sceeen lang pala master,hindi sya orifice tube.

  • @marlonrubi6137
    @marlonrubi6137 ปีที่แล้ว +1

    Sakin boss ganyan din bigla nawala lamig aircon lancer oto itlog or hotdog

  • @jeunessemenoto1243
    @jeunessemenoto1243 2 ปีที่แล้ว

    Sir , bumabaha ang oil ,nag kamali ng charge nasubra ang dag dag , .adali lang ma laman
    Sukat ng temperature deference ,.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Uu sir iba iba kasi ang gumawa kaya bawat gawa cguro naglalagay ng langis kaya yn bumabaha sa likod tpos barado pa

  • @SeigfredWall
    @SeigfredWall 2 ปีที่แล้ว +1

    Lods bakit may dumi na naipin sa filter saan ng galing yong dumi...

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Sadya po nagkakadumi ang cabin filter dahil sinasala ng filter ang hangin na hinihigop ng ac blower. At galing po yan sa loob ng sasakyan or sa labas fresh air. Depende po kasi air circulation button kung saan nakasettings.

  • @johnroudenguevarra7702
    @johnroudenguevarra7702 2 ปีที่แล้ว

    Sir ask ko lang bago overhaul ung ac ko. Bago valve bago drier bago evaporator pero nawawala yung lameg. Tapos pati tubog ng L mainit minsan. Minsan naman wala. Ibig sabhin nasira agad ung check valve?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Balik nyo po sa pinagpagawaan nyo. Maaring defective ang expansion valve. May mga factory defect kasi sa expansion valve.

    • @johnroudenguevarra7702
      @johnroudenguevarra7702 2 ปีที่แล้ว

      @@KenKejAutoElecTrix naka waranty pa naman to kaya babalik ko bukas. Kagabe kasi nawala yung lameg. Tapos bigla bumalik at lumameg ulit yung tubo as in malameg. Akala ko nga fuse at relay pinalitan ko pa orig. Pero nawala ulit ngayon ayaw na talaga lumameg aha

    • @johnroudenguevarra7702
      @johnroudenguevarra7702 2 ปีที่แล้ว

      Tska pla pag on mo compressor yung magnetic tunog hindi tik sound. Prang grind sound sya

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Silipin mo sir yong clearance ng clutch hub baka malaki ang kawang sa pulley. Baka kailangan bawasan ng manipis na washer.

    • @johnroudenguevarra7702
      @johnroudenguevarra7702 2 ปีที่แล้ว

      @@KenKejAutoElecTrix masikip naman. Sinusundot ko masikip pa. Yung pinagtataka ko lang sir. Bakit di tik sound pag on mo ac. Pang grind sound. Nissan sentra gsx unit ko manual 2005

  • @sonnysardoniecatalan6955
    @sonnysardoniecatalan6955 3 ปีที่แล้ว

    Chef..anong kaibahan pag itiwarik ang tank ng preon o pg i tayu.anung ga charge yan..thnkz

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว +2

      Pagnaka tiwarik boss liquid pag nakatayo gas. Sabi ng mga Master aircon technician pagnagcharge daw na naka off ang engine liquid pag naka ON ang engine start ang engine at naka on ang compressor gas daw, pero pag ako ang nagkakarga naka patay o umaandar ang makina liquid parin ang kinakarga. Iba ang lamig pag liiqud lahat. Kasi may kasamang gas narin naman ang liquid kung nakatiwarik ang tangke. Kasi ang gas ang matutulak sa liquid. Hindi namn makakaakyat ang liquid o hindi naman makakapressure kung wala itong kasamang gas. Pero tanong mo rin boss sa ibang Pinoy na TH-camr

    • @sonnysardoniecatalan6955
      @sonnysardoniecatalan6955 3 ปีที่แล้ว

      @@KenKejAutoElecTrixsalamat po dagdag kaalaman din po nagsasarili lng din akong mag karga freon....salamat chef.

  • @agapitoangeles3649
    @agapitoangeles3649 26 วันที่ผ่านมา +1

    bossing tanong ko lng bakit pag nag minor o tumigil na ang sasakyan bkit bumabagsak ang lamig
    sa mga nakakaalam na nandito paki share naman kung ano ang problema
    ang car ay toyota corolla 2019 salamat

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  26 วันที่ผ่านมา

      Malamang may Tama na po Ang compressor

  • @mechanicandaircontechnicia8272
    @mechanicandaircontechnicia8272 3 ปีที่แล้ว

    Boss ask LNG po , naka incounter ako. Ng Modelo na hullux malamig ang turbo. Niya exact ang reading niya piro but mainit SA loob.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Disconnect mo lang negative ng battery boss ng mga 5 minutes tapos balik mo tapos check mo.

  • @renjaylusung9046
    @renjaylusung9046 2 ปีที่แล้ว

    Panu pag napalitan na expansion valve ganun pa din evaporator daw barado nu gagawin sir

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Ang evaporator naman po hindi naman basta basta mababarahan. Expansion valve muna ang maapektuhan kung sakaling my dumi na papasok sa evaporator pero bago makarating sa expansion valve dadaan muna ng filter dryer. Kaya malabong mabarahan ng evaporator.
      Pwede pa yong fins ng evaporator baka puno na ng alikabok. Pero maramdaman nyo naman po yan pag barado na mahina na ang buga ng hanging kahit naka full na yong blower.

  • @dzycho2238
    @dzycho2238 2 ปีที่แล้ว

    sir tanong lang po, ano ibig sabihin if sa low pressure line is nasa 15, tapos sa high pressure line naman umaabot ng 280-300 psi. pano po bawasan ung nasa high perssure line?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Kung titingnan yong yong reading sa low side sir kulang pa ang freon at kung tingnan ang sa high side high pressure sya. Pacheck nalang sir yong auxiliary fan or radiator fan kung gumagana. At try nyo po basain ng tubig ang condenser kung baba ang pressure sa high side.
      Pagwalang pagbabago sa pressure kahit nabasa mo na yong condenser. Maaring may problema sa linya or barado.

  • @tyronedeleon9348
    @tyronedeleon9348 3 ปีที่แล้ว +1

    Good pm sir, follow up po ito sa case ng aircon ko. Bale sa reading sa gauge lowside 50 to 60 highside 200 ang sabi loose compression or mahina na ang compressor, pero kapag inapakan ang gas pedal bumababa ang lowside to 35 to 30 psi at malamig naman ang tubo sa lowside. Kindly enlighten po ako kung talaga palitin na ang compressor. Salamat po

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว +1

      Ganito po ang gawin mo sir buhusan nyo po ng tubig ang condenser at tingnan nyo kung baba ang pressure sa low side, pagbumababa good ang compressor paghindi bumababa may problema n ang compressor.

    • @mrdj-qb7os
      @mrdj-qb7os ปีที่แล้ว

      Na solve ba ito boss?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว +2

      @mr. dj walang update boss

    • @mrdj-qb7os
      @mrdj-qb7os ปีที่แล้ว

      @@KenKejAutoElecTrix sa akin kasi boss halos ganyan. Honda civic 2016 40lowside 200highside. D gaano malamig sa idle. Lumalamig lng ng todo kpg naka rekta na. Sabi ng ibang tech ok p dw compressor. Sabi nung isa mahina na bomba. Ung pipe hnd nagpapawis

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      Ilang po ba boss rpm nya pagnaka idle?

  • @michaelangelogodoy3494
    @michaelangelogodoy3494 2 ปีที่แล้ว +1

    Good day kabayan mag tanong lang po avanza 2017 model po unit ko nag palinis po last sept ok naman po ang lamig ngayon po humina ung lamig nya nuon. tapos napansin ko po humina ung lamig at medyo matagal bago umandar ung compressor hndi katulad dati half ung setting ko mblis lang umandar ang compressor. Chineck ko nman po tubo sa labas nag moist nman po at malamig. Ano po kaya problema ng ac ko ? Salamat po.

    • @michaelangelogodoy3494
      @michaelangelogodoy3494 2 ปีที่แล้ว +1

      Binalik ko po sa pnag pagawaan ko ok nman daw po ang refrigerant. Sabi po nila maaring ung evaporator daw po ung mga fins yupi yupi na kaya daw po na sesense ng sensor malamig pa pero hilaw na un bnubuga. Nanghingi lang po ako ng 2nd opinion bago ako bumili ng bagong evaporator salamat po.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      May heater po ba ang unit nyo sir. May heater hose ba na nakakonek papunta sa loob ng unit kung meron, subukan nyo po muna ibypass yang heater hose at check nyo po kung may pagbabago. Pagwalang pagbabago at ang sabi nyo po nag moist ang tubo maaring may problema ang expansion valve at kung bagong palit ang expansion valve maaring factory defect.
      Kung fins naman ng evaporator ang my problema dapat hihina ang buga ng hangin. At check nyo rin po cabin filter baka madumi lang.

    • @michaelangelogodoy3494
      @michaelangelogodoy3494 2 ปีที่แล้ว

      @@KenKejAutoElecTrix walang pong heater sir ung unit ko. Hndi ko pa po napalitan ung expansion valve nung car ko sir. Malamig nman po ung tubo nya.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Maaring expansion valve ang problema nyan sir kasi malamig ang tubo pero walang lamig sa loob

    • @michaelangelogodoy3494
      @michaelangelogodoy3494 2 ปีที่แล้ว

      @@KenKejAutoElecTrix may lamig nman po sya sir kaso po pag mainit na sa labas hndi po knkaya ng aircon tpos medyo matagal po bago umandar ung compressor parang nasa 20 to 25 seconds po bago mag on ulit ung compressor po.

  • @renjaylusung9046
    @renjaylusung9046 2 ปีที่แล้ว

    Anu sugest nyu gawin sir hilaw lamig sa harap malamig sa likod napalitan na expansion valve

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Baka defective ang ipinalit na expansion valve sir

    • @renjaylusung9046
      @renjaylusung9046 2 ปีที่แล้ว

      Pwde bang diagnosis ang oil sa loob ng evaporator kaya hindi naaatain ang optimal na lamig nya dapat flushing

  • @johndelfin6905
    @johndelfin6905 ปีที่แล้ว

    Bos,tanong lng ako,yung fortuner ko kasi matagal mag compressor ang sabi ng mekaniko thermistor daw.mga more than 1minute bago mag on ulit ung a/c kya ramdam mo yung init bago lamig ulit.tama ba bos?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      Wala po sa thermistor ang sira nyan sir... pwede AC amplifier ang may issue or yong switch o kaya may servo motor nag malfunction.

    • @johndelfin6905
      @johndelfin6905 ปีที่แล้ว +1

      @@KenKejAutoElecTrix naku,nka order na ako sa toyota...salamat boss.

  • @jherwinlinatoc7230
    @jherwinlinatoc7230 2 ปีที่แล้ว

    Sir, bakit kya ayaw po magcut off ang compressor pinaltan na po namin iyun thermostat switch at kakalagay din po ng freon at bago po iyun compressor? ano pa kya po iyun dahilan kung bakit ayaw magcutoff? Thank you !

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Try nyo po sir ilagay sa #1 lang ang speed ng blower at obserbahan nyo o kaya buhusan ng tubig ang condenser kung mag automatic cut off ba ang compressor, Pag ok sya ibig sabihin hindi lang naabot ang tamang temperature ng ac evaporator temperature sensor para mag cut off sya.

    • @jherwinlinatoc7230
      @jherwinlinatoc7230 2 ปีที่แล้ว

      @@KenKejAutoElecTrix Sir malamig naman po iyun AC kaso ayaw po talagang magcutoff.

  • @greazeman6279
    @greazeman6279 2 ปีที่แล้ว

    Good day sir San pba pwd man bawas Ng freaon pg overcharge ung system? Ty

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Sa discharge or low side po sir

    • @greazeman6279
      @greazeman6279 2 ปีที่แล้ว

      @@KenKejAutoElecTrix pano po nakapatay po Ang engine sir o umaandar? Salamat po sir

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Start po engine at naka switch on din ang A/C at dahan dahanin o pakunti kunti lang ang pasingaw sa low pressure valve hanggang sa magtuloy tuloy na ang engaged ng clutch hub. Pagtuloy tuloy na sarado nyo na ang valve at pakiramdam kung mag automatic on/off ang compressor.
      Dapat po naka low speed ang blower fan para mabilis po lumamig at mabilis mag automatic on/off ang compressor.

    • @greazeman6279
      @greazeman6279 2 ปีที่แล้ว

      @@KenKejAutoElecTrix salamat po sa info sir .

  • @marniefes8116
    @marniefes8116 ปีที่แล้ว +1

    Hello. Paps san kalimitan nkkbili ng orig n expansion valve? Thank you

  • @ferdinandnicolo9279
    @ferdinandnicolo9279 2 ปีที่แล้ว

    Boss kapag hilaw, mahina ang lamig na di kumakagat sa balat. Expansion valve po ba may bara kunti?? Nkapalit na ako ng compressor at evaporator pero mhina pa dn e.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Isa rin sa dahilan yan boss ang expansion valve

    • @ferdinandnicolo9279
      @ferdinandnicolo9279 2 ปีที่แล้ว

      @@KenKejAutoElecTrix boss tanong lanh pwede bang e adjust ang expansion valve to counter clockwise pra mas madaming freon ang ppasok sa evaporator at mabilis lumamig,? Npanuod ko lang di dto sa youtube. Safe ba un boss? Salamat ng marami

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Pwede naman sir kaso try and error ang mangyayari, kaya mas ok parin nalang ng bago

    • @ferdinandnicolo9279
      @ferdinandnicolo9279 2 ปีที่แล้ว

      @@KenKejAutoElecTrix okay sir salmat ng madami.. Godblss

  • @CertifiedKamote
    @CertifiedKamote ปีที่แล้ว

    Kanon po ba if gas lng ang narecharges sir. Nasa 60 to 50 na un low side. Un lamig medyo hilaw noon nag release kame ng gas medyo lumamig

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      Ampaw po ang lamig pagpuro gas

    • @CertifiedKamote
      @CertifiedKamote ปีที่แล้ว

      @@KenKejAutoElecTrix un po ba in minadali un pag karga ng freon sir

  • @madukkween2701
    @madukkween2701 2 ปีที่แล้ว

    Chevy sonic
    Normal reading sa gauge okay magnetic at pressure switch no high pressure
    Pag tapak accelerator nag stop ang pag ikot ng compressor at nawawala lamig sa vent ang hatok ng chevy mechanic thermistor tama ba?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Malayo po na thermistor ang sira kasi nag automatic cut off naman ang compressor.
      At kung tanungin nyo po ako kung ano ang sira..hindi ko rin po alam at dapat macheck ng actual para makita ang reading sa gauge.

  • @bryansoleta2101
    @bryansoleta2101 3 ปีที่แล้ว

    boss naglagay k p ng langis s pangatlong charge

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Madami kasi natapon na langis sa rear evaporator

  • @khenlarugal3699
    @khenlarugal3699 ปีที่แล้ว

    Tung hawak ko na mixer truck boss na howo biglang humina Ang lamig nya ano po Ang dahilan nya boss salamat Sana masagot po Ang aking tanung God bless po

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      Pacheck nyo po muna kung ok pa ang freon baka po kasi kulang na kaya mahina na lumamig.

  • @eliasperez4288
    @eliasperez4288 ปีที่แล้ว +1

    Paayos ko rin po aircon ng sasakyan ko sir mainit lumalabas

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว +1

      Pasensya na po sir wala po ako ngayon dyan sa pinas

    • @eliasperez4288
      @eliasperez4288 ปีที่แล้ว

      @@KenKejAutoElecTrix ok sir kung makauwi kayo saan kayo sa pinas?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      Cavite po sir

  • @dindollacuna770
    @dindollacuna770 2 ปีที่แล้ว +1

    sir paano ikabit manual thermostat

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Cut lang po isang wire ng stock na thermostat sir, At ang wire na putol ikabit sa magkabilaang terminal ng manual thermostat.

  • @papachoktv8251
    @papachoktv8251 2 ปีที่แล้ว

    May tanong ako sir...ung honda brv ko sir. 4/7 bars na prang no. 1 lng ng hyundai i10 ko..malamig naman siya pero mahina ang buga...bagong linis and palit ng filter ung brv..ano po kaya problem..na charge na din po ung freon

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Mahina po ba buga ng blower sir? Nalinisan narin po ba evaporator yong pins nya, kung nalinisan at mahina parin ang buga baka yong ac duct damper para sa airflow ang hindi naka solid face position kaya mahina ang buga.

    • @papachoktv8251
      @papachoktv8251 2 ปีที่แล้ว

      @@KenKejAutoElecTrix nalinis naman sir..mahina tlga siya..nka tutuk naman din airduct nya sir

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Yong ugong ng blower motor ramdam ba na malakas? Pwede naman alisin ang motor at paikot na hindi nakakabit sa bracket nya kung malakas pagnaka full switch

    • @papachoktv8251
      @papachoktv8251 2 ปีที่แล้ว

      @@KenKejAutoElecTrix pag nka max sir malakas naman ung blower.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Baka hindi na fit yong mga ducting nya kaya singaw na kaya mahina ang buga

  • @domingogarcia7752
    @domingogarcia7752 2 ปีที่แล้ว

    San shop no, mag paycheck also ng aicon, thanks,

  • @FrancoViodorRM
    @FrancoViodorRM 10 หลายเดือนก่อน

    Bakit tumataas ang reading sa gauge pag naka full yung blower ano po connection?

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  10 หลายเดือนก่อน

      Pagnaka full po kasi ang blower hindi na solid ang lamig sa evaporator at pansinin nyo rin po sir pagnakafull ang blower hirap din mag automatic ob/off ang compressor.

  • @jessielomibao9917
    @jessielomibao9917 2 ปีที่แล้ว

    Sir ken bakit sa kowside ko kapag nagengage ang comoressor tumatas yung lowside ng 45 psi kpag nagdisengage nmn bumababa ang lowside 35 psi ganon normal ba sir ken saka sa highside 160 psi lng sya. Salamat

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      50/50 na po yang compressor mo sir, nasubukan nyo po ba taasan ang rpm kung papalo pababa ang low side at tataas naman ang high side. Kung papalo man sya pero kunti lang, compressor na po ang may problema.

    • @jessielomibao9917
      @jessielomibao9917 2 ปีที่แล้ว

      Sir ken nagpapalit ako ng oring tapos kinargahan nila ng freon oansin ko yung manifold na gamit nila sira yung highside bali ngbase ong sila sa lowside at inantay kng nila magautimaic compressor at fan pwed ba yung ganong style pano nila mallman kng tama ang karaga ng freon di kaya over charge sir ken. Salamat

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Kung lagi mo ng ginagawa at yon talaga ang trabaho mo sir, ma estimate na nila ang dami ng refrigerant na kinakarga nila kung ilang grams na, pero mas ok parin low at high side nakikita ang pressure para may pagbabasehan kung maganda pa ba ang condition ng compressor at ang dami ng laman na refrigerant.

    • @jessielomibao9917
      @jessielomibao9917 2 ปีที่แล้ว

      Salamat sir laking tulong chanel nyo. Normal lowside ko sir 30/35 sya sa hiside nmn 150/170 lng sy

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +1

      Ahh normal lang pressure nya ibig sabihin good pa compressor mo

  • @kdjtv7421
    @kdjtv7421 2 ปีที่แล้ว

    gandang araw po..aramco ka nag trabaho bossing? kasi sasakyan ng security ang ginagawa mo...hehehe

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Contractor lang sa aramco boss

    • @kdjtv7421
      @kdjtv7421 2 ปีที่แล้ว

      Ok po ...dito ka sa dhahran na assigned bossing?

  • @willygocz6403
    @willygocz6403 9 หลายเดือนก่อน

    Dapat sa low side 30 to 37 high side 150 to 200 plus

  • @jansircbernardo5352
    @jansircbernardo5352 2 ปีที่แล้ว

    ung akin sir madalang gamitin ang sasakyan pa start start lng lagi sa garahe paano gagawin para hindi macra agad ang aircon

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Walang gagawin sir, kasi hindi naman magkakaroon ng problem kung wlang singaw. Ang problema lang sa hindi ginagamit si mabait na daga ang nagbibigay po ng problema ningangat ang mga wiring.

  • @vanderekcruel5832
    @vanderekcruel5832 2 ปีที่แล้ว

    Panu po kung mlakas buga ng hangin my lamig nman po peru hindi n kaya lumamig kung mainit ang panahon

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Kamusta po ba ang lamig, ang ibig kopo sabihin may lamig kasi na yong pakiramdam mo malamig sya pero hindi nangangagat sa balat yong lamig. Sa madaling salita hilaw ang lamig ampaw. O kaya kailangan lang tinted ang salamin para hindi gaanong absorb ang init sa loob

  • @michaelpacaco2386
    @michaelpacaco2386 3 ปีที่แล้ว +1

    Boss san ka sa ksa? Nkita ko kasi ung bote ng hanna eh.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Dammam boss

    • @michaelpacaco2386
      @michaelpacaco2386 3 ปีที่แล้ว

      @@KenKejAutoElecTrix kng jeddah ka boss na puntahan kita pra pa check ko ung sskyn ko ngpa carga aq freon boss ndi ko gngmit nawala nlng lamig

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Baka may leak boss, ano ba sabi nung nagkarga? Ano ba unit mo boss?

    • @michaelpacaco2386
      @michaelpacaco2386 3 ปีที่แล้ว

      @@KenKejAutoElecTrix boss sbi sakin evoporator na agd. Sinigil sakin pg inayos ay 900 agd, ndi man lng sinilip ng maayos.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Visual check mo muna sa labas boss yong mga tubo at condenser kung my mga langis langis kang nakikita, pagwalang sign na mga langis sa tubo at condenser malamang evaporator nyan. At kung malakas ang singaw may maamoy kang kakaiba pagbinuhay mo ang blower

  • @angelovalentin4050
    @angelovalentin4050 11 หลายเดือนก่อน

    Boss sa law side lng ba nag bavacuum

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  11 หลายเดือนก่อน +1

      Sa low side po at naka off engine pagnag vacuum

  • @generaldiy2771
    @generaldiy2771 2 ปีที่แล้ว

    Sir patanong. Bakit po di umaangat ang gauge ko, nasa 40/150 lang talaga sya. Tapos dinagdagan ko ng freon, naubos na lang half kilo, hindi tumataas. Hindi po nagbago ang reading kinabukasan or sa makalawa. So, walang yatang leak

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Pagnaka off ang engine sir ilang psi po sa low side

    • @generaldiy2771
      @generaldiy2771 2 ปีที่แล้ว

      @@KenKejAutoElecTrix pagka off ko ng engine, nasa 44/170. Pag-dating ko galing sa lakad, gauge agad ako, nasa 31/183. Pero hindi yun malamig gaano, nasa 14 deg lang.

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      May singaw po yan sir. Dapat tataas ang pressure sa low side pag off ang engine mga abot ng 100 psi

    • @generaldiy2771
      @generaldiy2771 2 ปีที่แล้ว +1

      @@KenKejAutoElecTrix sir yung sinabi ko pong 44/170, yan po yung pagka-off ko kaagad. Pero pagkatapos namin mag lunch, nasa 106/115 sir.

    • @generaldiy2771
      @generaldiy2771 2 ปีที่แล้ว

      Di ba po baka mas maraming hangin/vapor kaysa liquid ang na karga, meron bang ganun sir,?

  • @boknoyasmilon7160
    @boknoyasmilon7160 2 ปีที่แล้ว

    Boss paanu nmn kung subrang lamig at normal naman ang reading pero..pg tumatakbo habang tumatagal nawala ang lamig..pero pg tumigil ang sasakyan lamig uli..anunkaya ang problema boss

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว +2

      Check nyo po clearance ng clutch hub sa pulley baka naiiwan ang clutch hub o bumibitaw pag naka high RPM na. O baka nagyeyelo ang evaporator kaya nwawala rin ang lamig.

  • @edwardsucuano9190
    @edwardsucuano9190 2 ปีที่แล้ว +1

    Low sir ano ang dahilan kung bakit lagi nlng umiikot ang compressor tapos hndi malamig

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Kung gumagana ang compressor at hindi lumalamig, maaring kulang sa freon or may tama na ang compressor.. pasalangan nyo ng manifold guage sir para makita kung ano ang problema

  • @DowellvillaVilla
    @DowellvillaVilla 3 หลายเดือนก่อน +1

    Sir ano kya problema ng deminsion ko hangin lng siya walang lameg

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 หลายเดือนก่อน

      Baka wala ng refrigerant/freon ubos na

  • @romylapis2200
    @romylapis2200 ปีที่แล้ว +2

    loose compresion

  • @kimallenbinauhan7575
    @kimallenbinauhan7575 ปีที่แล้ว

    Sir tanung ko Yung saken vios 2008
    Malamig nman Sya sa tubo pero sa loob mahina Ang lamig

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      Condemn nyo po muna heater hose kung may heater pa. Pag ganun parin, expansion valve po palitan

  • @peterfadul4845
    @peterfadul4845 3 ปีที่แล้ว

    Pede ka mag home service

  • @cornelioduhaylungsod8987
    @cornelioduhaylungsod8987 3 ปีที่แล้ว

    sir kaylan lang pala kailangan mag lagay ng langis

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 ปีที่แล้ว

      Pagnag repair sa ac system sir. Halimbawa may singaw sa linya, nagpalit ng condenser, evaporator at compressor.

  • @jhamesvilleza-gx1oz
    @jhamesvilleza-gx1oz 3 หลายเดือนก่อน +1

    boss e ano kaya problema pag naka stop hilaw ang lamig tapos pag umaandar lumalamig nmn pero hilaw..parang di xa nagtutuloy tuloy.ano kaya posibleng problema

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 หลายเดือนก่อน

      Baka mahina na compressor sir

    • @jhamesvilleza-gx1oz
      @jhamesvilleza-gx1oz 3 หลายเดือนก่อน

      @@KenKejAutoElecTrix napansin ko lumalamig xa pag umaandar n lalo n s downhill o pag pababa kahit di n umapak sa gas.malakas ung lamig..pero pag nakahinto mahina n ang lamig

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  3 หลายเดือนก่อน +1

      Mas maganda po nyan sir masalangan ng manifold gauges para makita ang bomba ng compressor at malaman narin kung karga

  • @maritesbernardo4154
    @maritesbernardo4154 ปีที่แล้ว +1

    Good morning sir,,may ma extrahan ba dyan? Npansin ko lang pantalon mo, Kilala ko,, hehe...

  • @jehrizzz
    @jehrizzz ปีที่แล้ว

    Boss ung akin kya old model na lancer itlog bgong karga freon may lamig nmn pero sa tanghali wla sa gav lng meron anu kya problema

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      ilan po ba ang pressure sa low/hi side? At kung nagpapakarga po kayo dapat hindi binabasa yong condenser para malaman talaga ang tunay na pressure.

    • @jehrizzz
      @jehrizzz ปีที่แล้ว

      @@KenKejAutoElecTrix not sure sa hi and low kc ndi pinagawa ko lng paps pero bitin sa lamig

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      Balik mo boss sa pinagpagawaan mo para macheck nila

    • @jehrizzz
      @jehrizzz ปีที่แล้ว

      @@KenKejAutoElecTrix if ever mgkano kya ung ipalamiNated ng evaporator at condenser plit drier at expansion valve

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  ปีที่แล้ว

      Wala akong idea boss, bawat shop at supplier kasi ibat iba ang price at labor nila.

  • @noknok700
    @noknok700 2 ปีที่แล้ว +1

    Location nyo po p check kopo aircon ng L300 ko

    • @KenKejAutoElecTrix
      @KenKejAutoElecTrix  2 ปีที่แล้ว

      Cavite po sir, pero hindi po ako tumatanggap ng gawa