Pre Tensioning Vs Post Tensioning Concrete | Prestressed Concrete
ฝัง
- เผยแพร่เมื่อ 5 ต.ค. 2024
- Pre Tensioning Vs Post Tensioning Concrete | Prestressed Concrete
HOW TO Pre Tensioning Vs Post Tensioning | HOW TO STRESSING COMPLETE INFORMATION DYNAMIC JACK
HOW TO POST TENSIONING PIER TABLE | HOW TO STRESSING STEP BY STEP COMPLETE INFORMATION DYNAMIC JACK
Why Stressing
PSC Grider Stressing Work
PRESTRESSING
Hydraulic Jack Dynamic
Hydraulic pump Dynamic
Distressing Stressing complete information
How to Stressing Segment Bridge
Bridge Stressing
EXTRA
19Dp15
12DP13 system
12DP07 system
5S15 System
Vikramshila Setu
Rajendra Setu
Munger Ganga Bridge
Bhupen Hazarika Setu
Bogibeel Bridge
Bridges in Bihar
Vembanad Rail Bridge
Koilwar Bridge
Nehru Setu
Suspension bridge
Arch bridge
Deck
Span
Girder bridge
Truss bridge
Beam bridge
Prestressed concrete
Pylon
Road bridge
Welcome To Dynamic stressing
༆┈┅◉◆☆••••☆◆◉┅┈༆
FOLLOW ME ON FACEBOOK
/ zzmma02
FOLLOW ME ON INSTAGRAM
/ dynamicstressing
FOLLOW ME ON TWITTER
r_...
#PostTensioning
#PSCSegmentStressing
#Dynamicprestressing
Nice explanation..
Cable ki stressing uske bending moment capacity ko badane k liye ki jata hai .
Girder pe jab gadiya chalti hai to uske load k wajah se girder k slab me bending stress produce hota hai jisko bear karne k liye steel or strand dala jata hai .
Cable ka grade steel bar k grade se jayada hota hai .
Cable ka 1860 n/mm2 strength hoti hai jabki steel 500N/mm2 ki hota hai
Good news
Great explanation!
Nice 👍
Sir,
Apne bahut accha smjhaya
Lekin sir jo reading likhte h usko v dikhaye or or wo kaise likhte h please wo bhi bataye
Latest Videos Dekhiye
Use the pen marker(pointer) , don't use Whitner for live and dead end slip marking.
Before starting the process of post tentioning you must describe the design load and Elongation properties.
Before making the video Safety check at site ,first check all the safety measures.
(*Never use the word system like 19DP15 ,12DP13 Etc. , Use like 19T15,12T13 or 19K15,12K13 etc
Just because of Constant / Common system in pre-stressing engineering.
ET approved manufacturers only use the Company title. Dynamic Prestress is not ET approved standard.)
All components and dia aur unit ka ek special video bannaye
Which type stressing sir this
Sir calculation ka video kar dijiye na?
❤️❤️❤️❤️❤️❤️
Very nice
Sir Pressure calculation ka video banaye
Sir plz ek question hai ki pre-stress and post-stress koun karte hai ......???
Kaha par yea required hai aur kaha nehi ?
Plz bata na
Stressing Generally bridge Ke Span Me Hoata h Agar 30 Mtr Length Sey Kam Hai To Stressing Riquared Nahi Hota H But Depends Karta H Us Bridge Ke Load Capacity Kitna 3 mtr sey Agar Zyada Span H ya Segment Bridge H to Stressing karna Hi Padta h
Thanks vaiya
Her eak jack ka tressing vide ho apne channel pe dale
Sir strand Ka unit kiya hota hai
Bhai apna assistant bana lo agar koi seat khali hai .
Apni company me koi requirement hai to
Sir g 20- 25 psc girder k kya rate ho n chaiye
400kg pressure apply ka bad Ram kitna mm bahar aega
ELONGATION KITNA H DEPENDS KARTA H RAM KITNA BAHAR AAYEGA
Nice
Thanks
❤,👍
*In my site after introducing pressure pressure was drop in pressure gauge* why??
Agar 5 kg Drop Ho Raha h To Normal h
Agar Ussy Zyada Drop Ho Raha h To pressure Gauge Change Kijiye Agar Phir V drop Ho Raha h Lockoff Valve Open Karke O Ring Check kijiye Or Change Kar dijiye Problem Solve Ho Jayega
11 no. Pier ka kya process h
Saturday ko update aayega
Eske liye kaun sa Digri hona chahiye sir
Iti diploma B tech
Power pack ko kaise ripeyaer kare
Kya problem Aa raha h
Ram aria kitna he sir
200mm
430 pressur dene ke baad kitne pe. Lock kare
322 Locking pressure rahega
jitna Pressure Aap jaoge uska 75% locking pressure rahega
20-25mtr k
Apna number dena sir....kuch puchna hai