  • Activated sludge is worldwide the most used suspended growth process in wastewater treatment. The treatment process can include different steps, but most commonly are:
    - Screening and grit removal to filter out debris
    - Primary clarifier for particle sedimentation
    - Biological treatment with activated sludge consisting of an aeration basin, secondary clarifier and recycle stream
    - Disinfection for final removal of germs and bacteria
    (Zoom into biological treatment step)
    Wastewater entering the aeration basin still contains organic matter such as food waste and fecal. Microorganisms in the raw water influent will colonize in the aeration tank and metabolize organic waste to ATP for further cell growth as well as CO2 and water. As the microorganisms need oxygen to survive, the tank is aerated for example with diffuser systems. The amount of oxygen needed for biochemical processes is also known as the BOD value. BOD is a very important indicator for the level of wastewater pollution.
    To keep a good balance between the number of microorganisms, organic waste and oxygen, some microorganisms are settled down in the secondary clarifier. Adding flocculants will cause that microorganisms clump together with particles and settle down as activated sludge. Some of the activated sludge is then recycled back to the aeration basin whereas the rest is removed as waste sludge, thickened and then for example used as fertilizers. By recycling the activated sludge back into the aeration basin, the amount of microorganisms can be increased significantly - e.g. 30 times compared to the raw water influent. This is exactly the principle of activated sludge: To accelerate biological degradation significantly in a confined space.
    The sludge recycling rate does not only affect the sludge volume but also the sludge age. Young sludge (2 to 8 days) refers to microorganisms that metabolize organic waste as described before. Instead older sludge (older than 8 days) is used for nitrification processes to oxidize ammonium NH4+ to Nitrate NO3-. The sludge age can also be expressed as the SRT - Solid retention time. The SRT is the volume of the reactor multiplied with the concentration of solids divided by the excess sludge.
    The number of microorganisms present in the aeration basin and therefore the treatment capacity of an activated sludge plant is limited. The ratio of microorganisms and waste stream is also known as the MLSS - Mixed liquor suspended solids concentration. As higher the MLSS as less volume is needed to remove BOD from the waste stream. The maximum MLSS concentration for activated sludge basins is at about 3,500mg/l. However, by adding fixed film media into the aeration basin - also known as IFAS systems - the MLSS can be increased to up to 5,000mg/l meaning the treatment performance can be increased by up to 50%.
    Please click on the following video link to see in detail how the activated sludge process can be upgraded with fixed film media systems.

ความคิดเห็น • 30

  • @aryasreemol6817
    @aryasreemol6817 4 ปีที่แล้ว +7

    I searched for this video for a long time... now I got it....thank you sir ....!!! ☺️

  • @thekingdfn1001
    @thekingdfn1001 3 ปีที่แล้ว +6

    Thank you for the succinct explanation and animation. If you were to make a video detailing the differences between this plug flow system, step aeration, rotating biological contractors, and stabilization ponds, that would be amazing!

  • @sudhirgayakwad6766
    @sudhirgayakwad6766 2 ปีที่แล้ว +4

    Very well explained 👍

  • @rakzshanaudhayarakzshanaud9798
    @rakzshanaudhayarakzshanaud9798 4 ปีที่แล้ว +7

    Explained well👍

  • @paulmartinapostol8322
    @paulmartinapostol8322 ปีที่แล้ว +2

    informative video! what software did you use to create this video? thanks!

  • @spurthichadharam9144
    @spurthichadharam9144 3 ปีที่แล้ว +4

    Thank you, I think the treatment can or shall separate rheo water air and particle matter separately, it is better to keep this tanks closed much below the depth of ground and near trees to keep it more natural and healthy

  • @mohitm.gbrothers8150
    @mohitm.gbrothers8150 4 ปีที่แล้ว +2

    Very good explanation

  • @GauravGupta-pb8mk
    @GauravGupta-pb8mk 3 ปีที่แล้ว +3

    Thank you sir

  • @anshilbasnett4126
    @anshilbasnett4126 4 ปีที่แล้ว +4

    I liked very well explained

  • @maitripatel9070
    @maitripatel9070 4 ปีที่แล้ว +4

    well explained !

  • @marcmartins9894
    @marcmartins9894 2 ปีที่แล้ว +2

    Awesome work!

  • @jeevajeeva-lw1vn
    @jeevajeeva-lw1vn 4 ปีที่แล้ว +3

    Tq so much

  • @calvinouma3035
    @calvinouma3035 4 ปีที่แล้ว +3

    sludge keep on forming on top of secondary and primary setllers the tanks are lamella type of milk prodution waste

  • @hammadali4861
    @hammadali4861 4 ปีที่แล้ว +2

    well explanation! keep moving

  • @suneethabonu5676
    @suneethabonu5676 3 ปีที่แล้ว +2

    Very understanding 😄😄🤔🤔🤓🤓☺☺

  • @shivalilamuchandi2564
    @shivalilamuchandi2564 4 ปีที่แล้ว +2

    Nice sir well explanation tq sir

  • @spurthichadharam9144
    @spurthichadharam9144 3 ปีที่แล้ว +4

    Grit removal is not really necessary a it settles at bottom

    • @dosman7234
      @dosman7234 3 ปีที่แล้ว +4

      Grits will wear out pumps and pipes and settle where you don’t need it to settle. Or some of the grits may find it’s way in centrifuge or the incinerator and cause big problems.

  • @syazwanroslee657
    @syazwanroslee657 2 ปีที่แล้ว +2

    Can i know the logical amount of activated sludge in a plant?

    • @karl-uweschmitz3028
      @karl-uweschmitz3028  2 ปีที่แล้ว +2

      Hi Syazwan the amount of activated sludge is usually defined by the MLSS. The MLSS in a standard ASP process is often between 2500 and 3500mg/l.

  • @itzmerinuzforyouu2580
    @itzmerinuzforyouu2580 4 ปีที่แล้ว +2

    Tnx

  • @mekzwaterstream9474
    @mekzwaterstream9474 3 ปีที่แล้ว +1

    Mate, Can we return the sludge made from alum sulfate coagulation to aeration tank?

  • @Alex.1739
    @Alex.1739 3 ปีที่แล้ว

    Is another word secondary clarifyer humus tank/fst?

  • @neha34879
    @neha34879 3 ปีที่แล้ว

    The purified water is used for ?

  • @pearce_
    @pearce_ ปีที่แล้ว

    Humm interesting

  • @nicosadewa4649
    @nicosadewa4649 2 ปีที่แล้ว +1

    Woi subtitle indo gak ada apa

  • @engsaleemnawaz7091
    @engsaleemnawaz7091 ปีที่แล้ว

    Will any body provide me contact number of Sewage treatment plant complete equipment supplier