Thank You Sir for this video Can you link between stability curve and the out of step characteristic at the same moment because I didn't understand how we said that the out of step is starts after 90 degree and near 180 degree in stability curve but in out of step characteristic the out of step hapened after 180 degree
I have two questions regarding load angle 1) When ever the load increases load angle increase provided the excitation keep constant i.e no change in excitation current but what would happen to load angle if we increase excitation current. As per my knowledge excitation current only control voltage or VARs so how does load angle links with excitation current. Like we said it previously load angle will inc. if excitation is constant If excitation current keep increasing (Ignore Max Excitation limit) then what would happen to load angle if active load is constant.
Sir please make a video on Automatic Voltage Regulator working of large generator. I have searched a lot but unable to find a single satisfactory video regarding this. Person like you with such caliber only can make a video on this. So please try this for us sir.
Awesome video. You explanations are very clear as you kept the discussion very practical. Thanks for taking the time to create this!
Absolutely wonderful explanation 👌🏼
Sir after 2 years you came... its great sir.. thanking you
So kind to you sir for explaining concepts so easiest way and I hope in future you will continue share your valuable knowledge with us.....thanks
Nice to see you back with excellent video sir. Keep posting on power system.
Excellent knowledge sharing Sir You are Great Sir
Very good, keep it up
Very good lecture Sir. Thanks
Great explanation , thank you.
Very good explanation!!!!
😮very Good explanation
Great work. Thank you for everything
Thank You Sir for this video
Can you link between stability curve and the out of step characteristic at the same moment
because I didn't understand how we said that the out of step is starts after 90 degree and near 180 degree in stability curve but in out of step characteristic the out of step hapened after 180 degree
I have two questions regarding load angle
1) When ever the load increases load angle increase provided the excitation keep constant i.e no change in excitation current but what would happen to load angle if we increase excitation current.
As per my knowledge excitation current only control voltage or VARs so how does load angle links with excitation current.
Like we said it previously load angle will inc. if excitation is constant
If excitation current keep increasing (Ignore Max Excitation limit) then what would happen to load angle if active load is constant.
Sir please make a video on Automatic Voltage Regulator working of large generator. I have searched a lot but unable to find a single satisfactory video regarding this. Person like you with such caliber only can make a video on this. So please try this for us sir.
Thank You Very Much Sir
Kindly explain how the swing are detected n trips actuated...sir
Is this course important for gate exam ??
Reply please