American Standard Selectronic Flushometer | Piston | Repair and Replace

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ต.ค. 2024

ความคิดเห็น • 19

  • @ShiverPlumbingTN
    @ShiverPlumbingTN 2 ปีที่แล้ว

    Thanks , big help repairing American Standard Flush Valves for 1st time!

    • @AmreSupply
      @AmreSupply  2 ปีที่แล้ว

      You're welcome, we're just happy to help!

  • @andresmayen5579
    @andresmayen5579 3 ปีที่แล้ว +1

    Hi, thanks for your video, i`m very happy because have subtitles in spanish, this is good for me. Thank u!

  • @gordissibling8134
    @gordissibling8134 2 หลายเดือนก่อน

    What if I don’t have the Litte screw?

    • @AmreSupply
      @AmreSupply  2 หลายเดือนก่อน

      Thanks for watching. Do you mean there is no set screw on the back cover?

  • @valentinevega7090
    @valentinevega7090 2 ปีที่แล้ว

    So i tightened the bonnet nut down on to the piston and once I started to open , valve, water begins to fill pipe . I push manual valve and water begins to make it past piston in solenoid housing .Bad manual valve ? Not tight enough on bonnet nut ? I checked solenoid and its good , makes a click noise . Help would be appreciated .

    • @AmreSupply
      @AmreSupply  2 ปีที่แล้ว

      Thanks for watching. It is possible that the piston is not seated properly in the valve. It would be worth removing it, checking to see if there is any corrosion or mineral buildup in the valve and threads and reinstalling the piston.

  • @maynardbumagat2980
    @maynardbumagat2980 2 ปีที่แล้ว

    what would cause the urinals to not flush? the solenoid makes a click sound but does not flush... manual flush works

    • @AmreSupply
      @AmreSupply  2 ปีที่แล้ว

      There is one more thing to consider. A mineral buildup might prevent water from flowing when the solenoid opens. It would be good to open up the valve and try inspecting the piston and solenoid. Make sure that nothing is blocking the path between the two.

  • @davidhunter1358
    @davidhunter1358 2 ปีที่แล้ว

    will a malfunctioning piston create water hammer?

    • @AmreSupply
      @AmreSupply  2 ปีที่แล้ว

      Thanks for watching. It is possible though the piston is not as likely as a source of water hammer as compared to a pure solenoid valve like in a washing machine. Solenoid water valves are more instant in how they open and close. (Keep in mind the solenoid used in these flushometers only opens the bypass)
      You could check the rubber seals to see if they are sticking. In an ideal scenario, the seals should be tight but not sticking or preventing movement.

  • @freddybecerra397
    @freddybecerra397 2 ปีที่แล้ว

    How did you replaced The battery

    • @AmreSupply
      @AmreSupply  2 ปีที่แล้ว

      Thanks for watching. The battery can be replaced by following the steps in this video: th-cam.com/video/FWiwiZOptmA/w-d-xo.html

  • @michaelmunoz1007
    @michaelmunoz1007 2 ปีที่แล้ว

    WHat are these part #s and where are they listed in your catalog

    • @AmreSupply
      @AmreSupply  2 ปีที่แล้ว

      Thanks for watching. The best way of narrowing down the part number is to find the part sheet for your model like this one: www.amresupply.com/part/11203082 If you scroll to the bottom you'll find a few PDF's.
      Keep in mind there is some variation between models, like this one with a 10 year battery has a different piston and solenoid: www.amresupply.com/part/6066721-002-AmericanStandard-WC-Flush-Valve-10YR-Battery
      For example: M962907-0070A
      Is a common piston for urinal flushometers: www.amresupply.com/part/19508278?replaces=M962907-0070A

  • @shaikkareem1142
    @shaikkareem1142 6 ปีที่แล้ว

    Hi sir u have mor vdos please sand me please

    • @AmreSupply
      @AmreSupply  6 ปีที่แล้ว

      Hi Shaik, if you are interested in watching more videos please explore our channel th-cam.com/users/AmreSupply
      For more flushometer repairs, there are 80 videos in these playlists th-cam.com/users/AmreSupply/playlists?shelf_id=11&view=50&sort=dd