Dear Sir, I would like to congratulate you for the work you are doing to create these courses. I live in France and I am very interested in the subject of HT protection tests, I watch with great interest your videos. I would like to know if it would be possible for you to make news videos about these protections ANSI 40/59N/67N, explaining the working principle of each protection and to show an example of each test with Omicron Test Universe. Best Regards
Hi, First I want to thank you for the video, I have a question : How this function gets the status of the Circuit breaker ? is it with the binary inputs and the auxiliary contacts of the relay ? It will be very nice if you upload a video configuring Autoreclose with DIGSI 5, thanks.
Sir ,What will happen if Z2 operated with single phase earth fault and we have received carrier signal also the fault clearing time was 78 ms ,in such condition AR must be operated or not I mean AR works on Zone 2 or not ?
Dear Sir,
I would like to congratulate you for the work you are doing to create these courses. I live in France and I am very interested in the subject of HT protection tests, I watch with great interest your videos. I would like to know if it would be possible for you to make news videos about these protections ANSI 40/59N/67N, explaining the working principle of each protection and to show an example of each test with Omicron Test Universe.
Best Regards
Yes I will make for you soon
@@baranitech Thank you very much
Easily understood. Nice explanation!
thank you
Thank you so much,please make one tutorial detail how to work ABB REL670 auto Recloser function block
yes bro i will make soon
Thank you very much for the session. Just please increase the voice as it's not clear
yes i will increase voice
Can you explain CB ready status? What are the things should be need for CB ready?
CB- spring charge healthy
TCS healthy
CB position status
electrical interlock okay -( eg. earth swith co-ordination )
Hi, First I want to thank you for the video, I have a question : How this function gets the status of the Circuit breaker ? is it with the binary inputs and the auxiliary contacts of the relay ? It will be very nice if you upload a video configuring Autoreclose with DIGSI 5, thanks.
Binary input of the relay
Good teacher
Thank you!
Anna, pls make video of Auto re-closure working principle in Breaker and half system. Particularly Master and Slave method.
soon i will make bro
Please explain any connections between auto reclosure relay and PLCC
Yes I will make on video related to this topic
👍👍Good explanation
thank you
Sir
Please make a video for
IDMT.INVERS.VERY INVERSE setting
etc
Why and where use above setting
okay i will make
Sir ,What will happen if Z2 operated with single phase earth fault and we have received carrier signal also the fault clearing time was 78 ms ,in such condition AR must be operated or not
I mean AR works on Zone 2 or not ?
if its carrier signal received that mean it is in line so we can use AR
Clearly explained 👏👏
thank you
Thank you sir
welcome
Could you please help me understand the configuration of rex521 cap 505
Cap 505 i have seen very long ago.
Thanks nice video
welcome
Sir, how much millisecond dead time in 400 kv circuit breaker
1000ms
@@baranitech how to know dead time os ok different different voltage system 132kV,230kV
@@mr.biplob3795
Depend circuit breakers mechanism , relay processing ,
Super bro..
thank you bro.
Thanks u sir
welcome
Please add legends english on your's vídeos!
i am trying to improve my English slowly
Hi Sir
welcome sir
Ji ct testing uploaded
soon i will upload ji
Anna tamil la solluga anna
th-cam.com/video/RTXZokB19ko/w-d-xo.html
Thanks you sir
MOST WELCOME