- Cause
- motor not connected or motor contactor open.
- no DC link voltage present.
- Motor Module defective.
Remedy: - connect the motor or check the motor contactor.
- check the DC link voltage
- check the Motor Module.
In this case first we have to check motor winding.power cable and encoder cable if found ok then we can interchange the spindle drive with okay machine mostly motor defective.
Nice video sir
Nice 👌
sir Fanu ladder ka full explaine hindi me ab kijiye please bahot help hoga
We have facing same drive F2 over voltage alarm coming frequently . Need helf resolve problem
Sar vmc 810d main alarm no 400260 failiyar of machine control panel 1 alarm aa rha h solution btay sar
Siemens main S-LA43 aur S-LA22 ka kon sa alarm hai
Axis MA1 clamping monitoring alarm...need help
Sir semens control koi bhi drive on nhi ho rhi h Kya problem ho sakti
Hi, I have alarm Axis %1 waiting for drive; Plz?
Pls share vide, how to use call Subprogram instructions in siemens ladder
hello sir , we are using SINUMERIK 802D SL and error is came user alarm 17 drive not enable system not ready . please help
Siemens 840D control how can I take backup form pc
Sir i my company
Emergency alram is coming
"Drive plc module fault " Pls pls give us solution
Hello how to setting drive parameter dc drive 6RA80 and how to tunning motor dc...? Help me I wont learn.thankyou
siemens servo drive 55kw fault RDY iske liye kya Karen
828D Siemens control - Alarm 400015 profinet - I/O fault , sir plz solution
SIEMENCE SIMODRIVE SINUMERIC 8402d PLC AND CNC ALARMS NO 120202 NC PLC CONNECTION WAITING CONNECTION FAIL TO NC PLEASE HELP SOON
Siemens 802d alarm 012080 please solution
Sir read enable Missing alarm ata hai...drive run dikhata hai dono
Siemens 802D drive cnc lathe machine
Please guide
Bas axis move nai hote alarm koi nai dikhata khali read enable Missing dikhata hai reset nai hoti machine
Siemens 808 controler h
Axis Z1 fault code 504
Axis Z1 Hardwear fault active encoder
Power section of drive faulty
Sir meri machine mai 25202 alarm aa raha hai sp waiting for drive
Did you repair it?
Sir simenes controller par x0.0 par aane par alarm aata hai
Id mai face kar ne par aata hai
No spindle enable alarm.. Siemens control
Hi guys. I want to tell you that i passed with this problem since 1 month ago (but with Z axis).so i want to share with you the solution i found, is i just disconnected the drive cliq connected with servo motor (Z axis) and blow on it (used my breathing air). In the end it works
So maybe it will work with you.
@@fanucplcandcnc
You're welcome and thank you again for your great jobs
@@aymenkhalifadoukhi1826 25202 Axis %1 waiting for drive? help me.
Sir vmc Siemens control me emargency not released machine not reset hora hai please reply
If any alarm exist in Machine check, or Diagnosis Emergency PLC ladder, check all emergency signals are getting ON
E stop pb and press reset to start machine bolke alarm arahai sir
Dear sir plz help,
Solve the axis drive fault alarm
hii
mere machine me axis foult aa raha hai
How to solve 700028 tool unclamped
This alarm is PLC user Alarm
You check it into PLC ladder
Door auto locked kese off kre
Check any Keep Relay Bit for Bypass the auto door lock
X2 DRIVE FAULT
Why u don't talk English 💔