बहुत अच्छी जानकारी.भाई ड्रेनेज पाईपलाईन में चुहे PVC पाईप को होल करते है और पानी के साथ मिट्टी से पाईपलाईन जाम होता है तो पाईप कौनसे युज करने चाहीए ताकी चुहे पाईप को डॅमेज ना कर सके
Gupta Ji, Maine ek septic tank banawaya hai .abhi wah chaloo nahin hua hai Kintu usmen Pani bharne par roj Pani ghat jata hai.iske lie kya karna hai, kripaya Salah den.
Bhai humlog 10 fit gaddha karaye hai single tank ke liye ( without chamber) lekin bhai Pani oger (jameen se nikal raha h ) kya kare niche dhalai ke baad ye permanent bnd ho jaye aur baad mei problem nhi hoga na please bata dijiye 🙏🙏🙏🙏🙏
Agar dhalai ho jayega or diwal khada ho jayega to uske baad lick nhi karega lekin ek baat ka dhyan hona chahiye ki dhalai or plaster me Dr fixit ka ishtmaal jarur ho
Pl tell us which you are showing half half, you r connecting all outlets and also conecting air pipe ,but how it's acting ,pl show all connections in all moments for single tank
Hmare septic tank mei beech ke diwar ke ander msalana jane ki vajah se leakage tha par vo hmare ghr ke ander side tha isiliye humne use to bahar se chemical dal ke theek kr diya but diwar ki dusri side pados ka ghr hai jiski vajah se hum usko theek nhi kr paye aur na hi hume pta chla ki waha se koi leakage hai ya nhi aur ab hmara septic tank chalu ho gya hai aur hmara bathroom septic tank ke upper hi bna hua hai kripya aap btaye ki koi dikkat to nhi hogi aur agar hogi bhi to usko kaise theek kr skte hai taki aage jake koi problem na aye
@@jitendraguptaplumber9779 mtlb sir septic tank mei jo beech mei diwaar hoti hai usme sahi tarah se cement nahi gya tha isi liye waha se leak kr raha tha dono taraf se jo side hmare ghr ke ander thi use to theek kr diya tha par jo dusri taraf ke leakage thi vo theek nahi kr paye . leakage bht jyada nahi thi km hi thi .ab humne poora bathroom bnva diya hai . isiliye ma puch raha tha ki koi pareshani to nahi hogi .agar hum theek bhi krna chahte hai to kaise theek kr skte hai ye btayiye
Bhai aap solvent lga rhe ho swr ke pipe me q 🤔 swr me only lubricant and aapne borthroom ka pani and out let tanki ka ek me se leke ja rhe hai to pura Borthroom smeel dega
Ishke baare me aapko jankari bahut jald hin denge,aapke ish questions ka jawab video ke madhyam se Diya jayega,ushi video me bataya jayega ki system galat hai ya sahi. Dhanyawad... 🙏
OMB WALL MAGIC COAT क्या आप गर्मी से परेशान हैं क्या आप गर्मी से मुक्त होना चाहते हैं यदि हां तो हम आपके लिए लाए हैं गर्मी कम करने वाली बाहरी कोटिंग अंदरूनी शर्ते को लंबे समय तक ठंडा रखता है
एक पाइप में इसलिए जुड़े हैं क्योंकि मकान मालिक का पाइप कम लगा है और दूसरा बाथरूम में आपका कभी इस मेंल नहीं मारेगा क्योंकि बाथरूम में नहानी ट्रैप लगाया गया है
@@jitendraguptaplumber9779 मकान मालिक की बचत की है तो अच्छा है हो सकता है उसका मकान बनाने वाले मिस्त्री सरिया सीमेंट की बचा दिया हो कुछ हो सके तो एक अब हो सके तो आपके कमेंट बॉक्स में कमेंट कमेंट्स है उस मालिक को पड़वा देना आपको जरूरत आप शाबाशी देगा इनाम मिलेगा
Number lene ke lia hamare channel ka membership join kre apko number dikh jayega
Thank you brother swachhata sewa ke lia
Acchi Jankari dene ke liye dhanyvad sar
Dhanyawad
Mere gas vale payip me pani kyo aa rha h
@indrajeetyadav7032 outlet pipe se uper gas pipe lagwaiye, paani nhi aayega
Koi acchi jankari nhi he
Swr मे सोलवेंट नही लगत लूब्रिकेट लगता है 🤣🤣🤣🤣
Veri good mitra
Accha kaam kiya 👍
thanks
Good 👍
Good
bhai thanks aapne mari prblm solve kar
बहुत अच्छी जानकारी.भाई ड्रेनेज पाईपलाईन में चुहे PVC पाईप को होल करते है और पानी के साथ मिट्टी से पाईपलाईन जाम होता है तो पाईप कौनसे युज करने चाहीए ताकी चुहे पाईप को डॅमेज ना कर सके
बाथरूम मे वाश बेसिन के पास किचन में नहानी ट्रेप लगाने से चूहा अंदर नहीं प्रवेश करता है भाई पाइप कोई सा भी हो यह चीज लगाने से चूहा अंदर नहीं जाएगा
Sir mera gas pipe ka dhakkan aawaz ke sath ur Gaya he kiya galti se ura he bataye sir
सर आपने गैस पाइप को एंड कैप से बंद रखा था या कावेल जाली लगा हुआ था प्लीज आप बताएं
Sunder
Thank u
Nhani tap khan lgaya hai plege video bnaye
Please आप video मे सही नहीं बताना सकते है तो गलत भी मत बताइए ♥️♥️♥️♥️
भाई क्या गलत है यह तो बताओ
@@jitendraguptaplumber9779 मैने बता दिया
@@geniusgenius2518 aa
Outlet pipe me elbo me 2 inch lambe 2 cut b lagane he ya nahi gas pas hone k liye ?
Safti tank uper ha, pipe nichay ha, pire berker ruk jayga, pipe ka dal sit say tank tak dalai may hona chahiye
Jra jor se boliye bhai
Ok
Sir aapne jo outlet lagaya usme se pani uper chadega kya
Ha
Sir mera tanki 10fit gehra or 4fit lambai h single tanki h brick ka 10s 15din m pani bhr jata h sir koi upay btaye ki pani ni bhrey jldi
Kya app sapty tank se out let pipe nikale haii.agar nahi nikale hai to nikal le . Aapka problem slove ho jayega... 🙏🙏
Sir septic tank ka outlet naali में जोड़ सकते हैं.
हां सर जोड़ सकते हैं
Sir नाले से दुर्गंध ना आय इसका कुछ उपाय. Please reply sir apka subscriber हूँ
पी ट्रिप लगाइए
Mene outlet pain me kebal albo lagaya Hai Neche taraf paip nahi latkaya hai
ठीक है भाई
Gupta Ji, Maine ek septic tank banawaya hai
.abhi wah chaloo nahin hua hai
Kintu usmen Pani bharne par roj Pani ghat jata hai.iske lie kya karna hai, kripaya Salah den.
सर नया सेफ्टी टैंक जब बनता है तो पानी पहले वह सोख्ता है और उसके बाद सही हो जाएगा
Or 2 chamber m kitna down kare outlet
भाई इनलेट पाईप से आउटलेट पाइप डाउन डाला जाता है आप अपने हिसाब से वहां देख कर पाईप लाईन डालिए
@@jitendraguptaplumber9779 bohot smell aati h kuch upay batae
@@VishalSingh-xi6lr क्या आपका नया सेफ्टीटंकी चालू हुआ है
@@jitendraguptaplumber9779 ha 6 months ho gye h lekin smell aata h
Rcc cylindrical wala h
Kaun sa septic tank Achcha hota hai Balram tank ya FIR Bada tank
Single piece
Bhai mere yaha latin jane ke baad flash krne pr bahut smell aata hai kya kre gas pipe bhi lga hai
क्या आपके बाथरूम के सीट से स्मेल आता है तो साइफन सही नहीं फिटीगं हुआ है भाई
@@jitendraguptaplumber9779 फ्लश करने के बाद आती हैं
Bhai humlog 10 fit gaddha karaye hai single tank ke liye ( without chamber) lekin bhai Pani oger (jameen se nikal raha h ) kya kare niche dhalai ke baad ye permanent bnd ho jaye aur baad mei problem nhi hoga na please bata dijiye 🙏🙏🙏🙏🙏
Agar dhalai ho jayega or diwal khada ho jayega to uske baad lick nhi karega lekin ek baat ka dhyan hona chahiye ki dhalai or plaster me Dr fixit ka ishtmaal jarur ho
Ghar ke andar hi tank h
Or paip line b andar se h
Subh or sham ke time ghar me smell ata h kya problem ho sakti h
Salab ka uapar water proof karua laoo bhi
Bhai pipe lagane ka tarika galat hai usme solvent nahi lagta hai
Pl tell us which you are showing half half, you r connecting all outlets and also conecting air pipe ,but how it's acting ,pl show all connections in all moments for single tank
AAP thik se pure video ko dekhiye samajh me aa jayegi
Palambar ji Ap septi tank Aut let gaminke
Niche gaya he to upar karaneka to kai kare boliye
Samjh nahi aa raha
Hmare septic tank mei beech ke diwar ke ander msalana jane ki vajah se leakage tha par vo hmare ghr ke ander side tha isiliye humne use to bahar se chemical dal ke theek kr diya but diwar ki dusri side pados ka ghr hai jiski vajah se hum usko theek nhi kr paye aur na hi hume pta chla ki waha se koi leakage hai ya nhi aur ab hmara septic tank chalu ho gya hai aur hmara bathroom septic tank ke upper hi bna hua hai kripya aap btaye ki koi dikkat to nhi hogi aur agar hogi bhi to usko kaise theek kr skte hai taki aage jake koi problem na aye
Smjh nhi pa rhe haii
@@jitendraguptaplumber9779 mtlb sir septic tank mei jo beech mei diwaar hoti hai usme sahi tarah se cement nahi gya tha isi liye waha se leak kr raha tha dono taraf se jo side hmare ghr ke ander thi use to theek kr diya tha par jo dusri taraf ke leakage thi vo theek nahi kr paye . leakage bht jyada nahi thi km hi thi .ab humne poora bathroom bnva diya hai . isiliye ma puch raha tha ki koi pareshani to nahi hogi .agar hum theek bhi krna chahte hai to kaise theek kr skte hai ye btayiye
Mere septik tank se outlet drainage water ke sath gas niklata rehta h jabki inlet pipe ke sath gas pipe laga hua h , usko sahi kaise kiya jaye?
आउटलेट पाइप में अंतिम में पी ट्रैप लगा दीजिए सही हो जायेगा
3-4 person ke liye septik tank ka map kya rakhe ?? kitna chamber kare taki?? taki jyada dun tak chale..design v bataye.
8-8 ya 10-10 area ke hisab se banwa sakte hain
Safety ke pipe se outlet ka pipe ka hight kitna hona chahiye
इनलेट पाइप से कम से कम चार इंच नीचे आउटलेट होना चाहिए ।जगह के अनुसार और नीचे भी लगा सकते हो।लेकिन बहुत ज्यादा नहीं
Bhai is fitting me solvent nahi lagaya jaata hai
Bhai kya lagaya jata hai please bataiye
Usame tee lagna tha bhaiya jaam ho sakte hai kabhi bhi
आप टी ओर बेन्ड लगा सकते हैं नहीं जाम हो गा
आप कहां से हैं भाई
मेरा यही वाला सेपटील टेक बना हुआ हे चेबर से पुरे घर मे बदबू आती हे क्या करे अन्दर पाईप की सिर्फ कुनी डली हे टेक मे पाईप का टुकडा नही डाला हे
क्या करे बताए
9934839307 pe call kijiye
Solution mil jayega
क्या आपने सेफ्टी टैंक में एयर पाइप लगा है नहीं लगा है तो लगवा ले और बाथरूम में नहानी ट्रैप और किचन में जरूर लगवाएं बदबू नहीं आयेगा
Bhai MerA septic tank me Bahut pani bhar Gaya h Kya kre
आवट लेट पाईप डालिये पानी बाहर निकलता रहे गा
सर मेरा दो टॅंक वाला टॉयलेट हे पर वेस्ट बाहेर आताहे क्या करू
भाई लैट्रिंग बाहर आ रहा है यह पानी बाहर आ रहा है
Pipe elbow ke. Sath Pani me dibo do 3se 3 feet
Samjh hi aaya.pani kha kaise aayega aur bahr kaise jayega? Video sahi nhi banaya h.
Washbasin ke pipe se washbesin me smell nahi ayegi kya septic tank ka paani jab chlega ?
नहानी ट्रैप लगाने के बाद स्मैल नहीं आता है
Sur mere toilet me outlet ki taraf badhbu aa raha hai kya karu please batao
और कोई यूज़ करता है तो बहुत बदबू
भी आती है
भाई 2 टॅन्क वाला है बास मार रहा क्या करू please help
Bhai aap solvent lga rhe ho swr ke pipe me q 🤔 swr me only lubricant and aapne borthroom ka pani and out let tanki ka ek me se leke ja rhe hai to pura Borthroom smeel dega
भाई यहां पर लुब्रिकेंट नहीं मिलता है और बाथरूम और किचन और वाशबेसिन के पास में नहानी ट्रैप लगाया गया है जिससे बदबू आपका नहीं आएगा
Badbu aay gi
Maine tudwake dono pipe ko alag kar waya hai
SWR pipe mein solvent nahin lagta
जिस समय यह काम हो रहा था उस समय यहां का मार्केट में लुब्रिकेंट नहीं मिल रहा था भाई
मेरा टैंक का ओवर फ्लो का लेवल सीसी रोड से 6 इंच नीचे हो गया अब केसे पानी बाहर जाएगी
Mere bhi same problem hai.. Koi solution mile toh btana
प्लंबर से मिलिए ठीक हो जाएगा
प्लंबर से संपर्क कीजिए
Inlet, outlet and vent pipe ka size kya hona chiyaee
Kaam ke hisab se 4"ya 6" hona chahiye
मियानी टेप क्या होता है, जिससे गंध बाथरूम में नहीं जाएगा ।
नहानी ट्रैप होता है भाई
नहानी
सिस्टम गलत है टैंक के मोड़ पर पाइप नीचे से उपर है दिक्कत दे सकता है
Ishke baare me aapko jankari bahut jald hin denge,aapke ish questions ka jawab video ke madhyam se Diya jayega,ushi video me bataya jayega ki system galat hai ya sahi.
Dhanyawad... 🙏
सेप्टीक टँक का ढक्कन नही मिल रहा है.....तो पाईप डालके वेस्ट मटेरीयल बाहर कैसे निकाले
ढक्कन नहीं मिल रहा है तो सेफ्टी टैंक में होल कर दीजिए
गडर के उपर चेंबर नही देना है. उसके जगह पर पाईप लगाना है तो कितने इंच का लगाना पडेगा.
आगे जाकर गडर साफ करणे मे परेशानी नही होनी चाहिये.
4" से 6" तक पाईप
Bend laga h par niche paip nhi dala h tanki m
Septic water ka pipe water line mat milav Ganda bas ayega
Work super
Agar naali. Ks level. Tank. Level. Ooncha ho. To kaise. Karen
Pura galat hai bhai
OMB WALL MAGIC COAT क्या आप गर्मी से परेशान हैं क्या आप गर्मी से मुक्त होना चाहते हैं यदि हां तो हम आपके लिए लाए हैं गर्मी कम करने वाली बाहरी कोटिंग अंदरूनी शर्ते को लंबे समय तक ठंडा रखता है
Bhai l Bo panchar karke lagana chaiye
मेरा सेप्टिक टैंक बनने में 6 महीना भी नहीं हुआ है और दुर्गंध के साथ साथ आउटलेट से लैट्रिन बाहर आता है क्या किया जाए उपाय बताएं
सेफ्टी टैंक के आउट पाइप में अंदर में आप बैंड या टी लगाऐ उससे आपका स्मेल भी नहीं आएगा और लैट्रिंग बाहर नहीं आएगा
Bhaiya jb tank bhara hai tb kaise lagayenge @@jitendraguptaplumber9779
Tanki connection galat h
आप बताओ कैसे होगा
Bhai abhi tak aap jawab nhi diye?..
Kya galat h batao,ho sakta hai aapke batane se agale video me sudhar kar lun...
Aur dusarr k ghr me pani ja raha h
Bhai humara overflow wala pipe tank se pani nhi nikalta kya kare?
आप पहले पाइप को चेक कीजिए टैंक में कितना पानी है कि नहीं
Ye kam galt h
Bhai pahle master bano fir kisi ko sikhao
Galat processing
भाई क्या गलत है
Galat tarika se laga raha hai
Pehle khud Sikh lo uske baad dusro ko sikhana Bada aaya engineer banne khud to Kuch aata nhi aur Hume sikhane chale
Ho sakta hai aap hamse सीनियर हो but hamne to puchha ki kaise hoga
Sir agar inlet se 3inch outlet down hai to
Apka mobail nmb dena sir
आप हमारे मेंबरशिप में ज्वाइन कीजिए वहां से नंबर मिल जाएगा सर
Abhi khud Sikh lo
App sikha dooo 🙄
बेवकूफ फिटर बर्बाद कर देगा उसे जिसका यह काम करेगा उसे
तुम ज्यादा जानकारी वाला है इसलिए तो ऐसा बात कर रहे हो, गलत क्या है ये बताओ मुझे।
@@jitendraguptaplumber9779 तुमने जो फिटिंग की है उन सबको एक पाइप में जोड़कर गलत किया अगर जगह थी तो टैंक और बेस्ट वाटर पाइप अलग-अलग रखने चाहिए
एक पाइप में इसलिए जुड़े हैं क्योंकि मकान मालिक का पाइप कम लगा है और दूसरा बाथरूम में आपका कभी इस मेंल नहीं मारेगा क्योंकि बाथरूम में नहानी ट्रैप लगाया गया है
@@jitendraguptaplumber9779 मकान मालिक की बचत की है तो अच्छा है हो सकता है उसका मकान बनाने वाले मिस्त्री सरिया सीमेंट की बचा दिया हो कुछ हो सके तो एक अब हो सके तो आपके कमेंट बॉक्स में कमेंट कमेंट्स है उस मालिक को पड़वा देना आपको जरूरत आप शाबाशी देगा इनाम मिलेगा
Faltu vedeo
Phle video thik se likhna sikh loo 😂🫵
सर मुझे आपका मो.नंबर चाहिए,सेफ्टी टैंक के बारे बात करनी है।
9934839307
Sir Mera new septic tank hai
Maine autlet me t lga kr 1fit paip ltka Diya hai
Inlet paip Aise chhod Diya hai
To theek h
ठीक है सर
Thanks sir
Sir
Mera septic tank 2 chamber me hai start kaise kre
Full tank bhrke ya half
App kahan se hai app ka number chahiye
Bihar ..
For more information plz follow on Instagram
अपना नंबर दो
Apna number dijiye
gupta ji aap se bat karana hi apana mobile number dijiye
9934839307
Good
Good
Nice
Nice
Good
Good
Good