SM35 Parallel Operation of Alternators under Loaded condition

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 พ.ย. 2024

ความคิดเห็น •

  • @ठाड़ाचेला
    @ठाड़ाचेला 3 ปีที่แล้ว +1

    वाह मजा आ गया सर जी इसमे तो,ये सच मे मैने पहले नही पढ़ा, धन्यवाद

  • @johnhonai4601
    @johnhonai4601 ปีที่แล้ว

    Thank you, Sir. I used to learn byheart "Excitation Increase, KVAR increase".
    But this diagrammatic representation helps very much.

  • @rupaliukey2909
    @rupaliukey2909 4 ปีที่แล้ว +2

    Salute sir ,the way you are teaching is excellent ,I have done coaching in topmost academy but still i get something new from your lectures , no one explained this in detail ,tysm🙏

  • @surendrakverma555
    @surendrakverma555 2 ปีที่แล้ว

    Excellent lecture Sir. Thanks 🙏🙏🙏🙏🙏🙏🙏🙏🙏

  • @satyavara6276
    @satyavara6276 4 ปีที่แล้ว

    Excellent explanation sir

  • @dmo4657
    @dmo4657 4 ปีที่แล้ว +1

    Sir, at 17:10 you have taken the angle ⌀2 from the kVAR axis. If power factor is decreasing then the angle ⌀ is supposed to be increasing.

  • @sheshusmart3300
    @sheshusmart3300 3 ปีที่แล้ว

    Tq you saved my sem

  • @visheshsingh1238
    @visheshsingh1238 4 ปีที่แล้ว

    Nice explanation sir

  • @gustavomarcelo7250
    @gustavomarcelo7250 2 หลายเดือนก่อน

    How do we carry out the same analysis for 3 generators?

  • @muhammedanfas7873
    @muhammedanfas7873 3 ปีที่แล้ว

    thank you sir ,thank you very much

  • @3dgiftz
    @3dgiftz 2 ปีที่แล้ว

    Good

  • @MANOJKUMAR-mb2uw
    @MANOJKUMAR-mb2uw 4 ปีที่แล้ว

    One shot clear🙏🙏🙏🙏

  • @pudurusuresh8644
    @pudurusuresh8644 2 ปีที่แล้ว

    Sir at 22.23 why the two machines characteristics are falling down

  • @arindamchowdhury4734
    @arindamchowdhury4734 4 ปีที่แล้ว

    Sir.. when load is connected .. if I increase excitation of one alternator.. then it will be accelerated.. because inorder to maintain same speed if excitation is increased then power angle(delta) should be reduced.. so ..will the whole combination will be distabalized??

  • @jassalg7169
    @jassalg7169 2 ปีที่แล้ว

    Sir we can maintain stable power factor during parallel operation of alternator
    Sir actually during parallel operation when first alternator execution is increase then power factor of first alternator is leading and secondary alternator power factor automatically leading. Then second machine is tripping frequently due to reactivate power
    Sir how to solved this fault ?
    Pls reply 🙏

  • @petchu2002
    @petchu2002 4 ปีที่แล้ว

    Dear sir
    I have one more confusion that whenever we draw voltage vector for two alternator in opposite direction ,it means angle between them is 180? supposed to be both are peak at same instant ans zero at same instant means zero phase angle.

  • @maheshwarreddy3656
    @maheshwarreddy3656 5 ปีที่แล้ว

    Sir when alternator connected to bus bar if we increase prime mover input why speed is not changing?

  • @prasannakumar2638
    @prasannakumar2638 4 ปีที่แล้ว

    8:02 Since KVAR 1 and KVAR 1' are in negative y-axis, KVAR1 should be greater than KVAR1' right?

  • @petchu2002
    @petchu2002 4 ปีที่แล้ว

    Dear sir
    Please clarify that at first vector diagram IxR and IxX why they are being drawn at this direction.IR might be in phase with V. Please explain the reason why they are drawn at that angle.
    Thanks

    • @petchu2002
      @petchu2002 4 ปีที่แล้ว

      Dear Sir thank you very much for clarification and response.
      And I have one more confusion that whenever we draw voltage vector for two alternator in opposite direction ,it means angle between them is 180? supposed to be both are peak at same instant ans zero at same instant means zero phase angle.

  • @er.imransiddiqui
    @er.imransiddiqui 3 ปีที่แล้ว

    Sir, how can we say that the magnitude of generated voltage does not change with frequency although the emf equation(E=2.22 f × phi × Z) has the frequency term and what is justification for the change of phase of emf with frequency?

    • @er.imransiddiqui
      @er.imransiddiqui 3 ปีที่แล้ว

      @@lecturesinelectricaleng
      I watched the video. What I am still thinking is that when the speed of the prime mover changes the frequency as well as the induced voltage must change. Because E= 4.44 f × phi × T.

    • @er.imransiddiqui
      @er.imransiddiqui 3 ปีที่แล้ว

      @@lecturesinelectricaleng
      Ok sir. But then here in the second case you have assumed that the magnitude of E1 and E1' are same, only phase is changing. I want the reason for both - (1)why magnitudes have been considered same here and (2) what is the proof that phase changes with speed/frequency?

    • @er.imransiddiqui
      @er.imransiddiqui 3 ปีที่แล้ว

      @@lecturesinelectricaleng
      Ok
      Thank you Sir.

  • @sasidher8922
    @sasidher8922 4 ปีที่แล้ว

    Sir,what happens if prime mover has rising characteristics ,can't they share load equally in this case?

    • @sasidher8922
      @sasidher8922 4 ปีที่แล้ว

      Sir, can you tell reason for it?

  • @shaileshbirajdar1963
    @shaileshbirajdar1963 4 ปีที่แล้ว

    👏👏👏👏

  • @pbsaikumar3553
    @pbsaikumar3553 4 ปีที่แล้ว +1

    Sir,please reduce the speed while explaining the any concept

    • @dmo4657
      @dmo4657 4 ปีที่แล้ว

      Watch at 0.75 speed.
      The speed is fine.